Hp DL560 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Computadores Hp DL560. HP DL560 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 35
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1. Dual 550W Hot Plug Redundant Power
2. 2U (3.5" Height) rack form factor
3. PCI-X Riser Cage, Three 64-bit PCI-X slots
4. Six memory DIMM slots
5. Tool-less "Snap in" Rail Solution
6. Hood
7. LEDs
8. Slimline Removable media Bay with 24x CD-ROM installed
9. Hood latch (accesses processors and fans)
10. 1.44 MB Diskette Drive
11. Wide Ultra3 SCSI drive cage for two hot plug hard drives
or one DAT hot plug tape drive (plus 1 hard drive)
12. Hot Plug Fans
13. DC Power Converter Module
What's New
Intel® Xeon® Processors MP at 3.0 GHz/4MB, 2.7 GHz/2MB, or 2.2 GHz/2MB (Expandable to 4 processors)
At a Glance
Intel Xeon Processors MP at 3.0 GHz/4MB, 2.7 GHz/2MB, 2.2 GHz/2MB, 2.8 GHz/2MB, 2.5 GHz/1MB, 2.0 GHz/1MB
(Expandable to 4 processors)
The HP ProLiant DL560 delivers extraordinary performance and maximum power efficiency in an ultra dense, rack
optimized form factor ServerWorks Grand Champion-LE chipset
2x1 interleaved memory, 200MHz DDR SDRAM Memory (PC2100 Registered SDRAM with Advanced ECC
functionality)
1024 MB or 512 MB (depending on model) standard memory, expandable to 12 GB
HP Advanced Memory Protection
Two, full length 64-bit/100 MHz Non-Hot Pluggable PCI slots, one full length 64-bit/133 MHz Non-Hot Pluggable
Integrated Lights-Out Standard Management (iLO) on system board
Two NC7781 PCI-X Gigabit NICs (embedded)
Integrated Smart Array 5i Plus Controller (Ultra3) with 64-MB total memory on 5i Plus Memory Module
Battery-Backed Write Cache Enabler module on all 2P models (optional on 1P model)
Internal Hot Plug Drive Storage of up to 600 GB (2 x 300 GB 1" Ultra320 hard drives)
Redundant Cooling Zones for major subsystems (Memory, I/O, CPUs) assure 7x24 cooling
Toolless and virtually cable-less internal design
Rapid Deployment racking solution (rack rails and cable management)
Protected by HP Services and a worldwide network of resellers and service providers. Three-year Next Business Day,
QuickSpecs
HP ProLiant DL560
Overview
DA - 11595 Worldwide QuickSpecs — Version 46 — 12.16.2005
Page 1
Vista de página 0
1 2 3 4 5 6 ... 34 35

Resumo do Conteúdo

Página 1 - QuickSpecs

1. Dual 550W Hot Plug Redundant Power2. 2U (3.5" Height) rack form factor3. PCI-X Riser Cage, Three 64-bit PCI-X slots4. Six memory DIMM slots5.

Página 2

Factory ExpressPortfolio for Serversand StorageHP Factory Express offers configuration, customization, integration and deployment services forHP serve

Página 3

DL560R01 X3.0GHz-4MB, 1024MB (2P)346921-xx1Processor(s)(2) Intel Xeon Processors MP at 3.0 GHz standard (up to 4 supported)Cache Memory4MB Integrated

Página 4

DL560R01 X2.2-2MB,1024MB (1P)346919-xx1Processor(s)(1) Intel Xeon Processor MP at 2.2 GHz standard (up to 4 supported)Cache Memory2MB Integrated Level

Página 5

ProLiant EssentialsValue Pack SoftwareProLiant Essentials Integrated Lights-Out Advanced PackProLiant Essentials Integrated Lights-Out Advanced Pack,

Página 6

virtual machine. Or this license can be used to migrate a virtual machine fromone virtualization layer i.e. VMware GSX to a different virtualization l

Página 7

Hard DrivesUltra320 SCSI - Universal Hot Plug300-GB 10,000 rpm U320 Universal Hard Drive (1")350964-B22146.8-GB 10,000 rpm U320 Universal Hard Dr

Página 8

(SCSI Adapter)http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.HTML(U320 Adapter)CommunicationsHP NC310F PCI-X 1000SX Gigabit Server

Página 9

HP StorageWorks 1U Rack-Mount KitNOTE: The 1U Rack-mount Kit can support up to (2) half-height tape drives andcompatible with multiple Single-Ended an

Página 10

Tape LibrariesHP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 1 Ultrium 960 Drive LibraryAG115AHP StorageWorks MSL2024 1 Ultrium 448 Driv

Página 11

Cluster OptionsProLiant Cluster Starter Kit364023-B21NOTE: For additional information regarding the ProLiant Cluster Starter Kitplease see the followi

Página 12

on-site limited global warranty. Certain restrictions and exclusions apply. Pre-Failure Notification on processors,memory, and SCSI hard drives.QuickS

Página 13

HP StorageWorksModular Smart Array 20HP StorageWorks Modular Smart Array 20NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,

Página 14

Uninterruptible PowerSystems – RackHP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA)204404-001HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (I

Página 15

Modular PowerDistribution Units1U/0U(Up to 32 outlets)NOTE: 1U/0U mountingbrackets shipped withthe unit (optimized for10000 and 9000 seriesracks).HP M

Página 16

NOTE: -B21 (pallet) used to ship empty racks shipped on a truck-B22 (shock pallet) used to ship racks with equipment installed (by customsystems, VARs

Página 17

NOTE: Cat5e cables are required to connect Interface Adapters to ConsoleSwitches. Cat5e cables can be found at the following URL:http://www.hp.com/go/

Página 18

Installation & Start-up ServicesHardware Installation, ElectronicU4707EInstallation & Start-Up of a ProLiant server and Microsoft or Linux O/S

Página 19

HP ProLiant DL560Standard Memory1024 MB PC2100 Registered DDR SDRAM DIMM Memory comes installed (2 x 512 MB SDRAM)Standard Memory Plus Optional Memory

Página 20

A1.44-MB Diskette DriveBEjectable: 24x IDE CD-ROM (Slimline)0-1Wide Ultra3/Ultra320 Drive CageDrive Support QuantitySupportedPositionSupportedControll

Página 21

determineconfigurationrequirements Modular Smart Array1500 csPlease see theModular SmartArray 1500 csQuickSpecsbelow todetermineconfigurationrequireme

Página 22

Ultrium 230Ultrium 232Ultrium 448Ultrium 460DAT 40DAT 72DLT VS80DLT VS160SDLT 320Alternate OS HP StorageWorks TapeDrives, ExternalUltrium 960SDL

Página 23

ProcessorOne of the followingdepending on Model(2P) Intel Xeon Processor MP 3.0 GHz/4MB (Expandable to 4 processors)(2P) Intel Xeon Processor MP 2.7 G

Página 24

Part Number280126-001Spare Kit280126-B21Operational Input VoltageRange (V rms)90 to 264Frequency Range (Nominal)(Hz)47 to 63 (50/60) Nominal Input V

Página 25

System Unit RackChassis Footprint(HxWxD)3.38 x 17.50 x 25.75 in (8.59 x 44.45 x 65.41 cm)WeightMaximum (2 PowerSupplies, 2 Hard Drives)60 lb (27 kg) M

Página 26

24X Max (or higher) IDECD-ROM Drive SlimlineDiskApplicable DiskCD-DA, CD-ROM (Mode 1 and 2) CD-XA, CD-I (Mode 2, Form 1 and 2) Photo CD (Single and

Página 27

CD-I (mode 2) CD-I Ready CD-Bridge CapacityDVD-ROMDVD-SL4.7 GB/side DVD-DL8.5 GB/side DoubleSided9.40 GB/side DVD-R 3.95 GB/side DV

Página 28

Integrated Lights-OutStandard (integratedon system board)Architecture32-bit PCI-based health and remote management ASIC (ApplicationSpecific Integrate

Página 29

Battery-Backed WriteCacheYes, with installation of Battery-Backed Write Cache Enabler, up to64MBRAID Support0, 1Logical Drives(maximum)Maximum = total

Página 30

Storage DataProtectionThe Battery-Backed Write Cache (BBWC) Enabler protects up to 64-MB write cache memory fromhard boot, power, controller, or syste

Página 31

SmartStartSmartStart is a tool that simplifies server setup, providing a rapid way todeploy reliable and consistent server configurations. For moreinf

Página 32

management and control of virtual machines from Microsoft andVMware. Integrated approach provides the ability to manage bothphysical and virtual resou

Página 33

AvailabilityStandard Advanced ECC functionality detects and corrects single bit and specific multi-bitmemory errors (4bit and 8bit) while using indust

Página 34

SecurityPower-on passwordKeyboard passwordDiskette drive controlDiskette boot controlNetwork Server ModeSecurity ProvisionSerial interface controlAdmi

Página 35

OS SupportMicrosoft Windows 2000Windows Server 2003Novell NetWareLINUX (Red Hat, SuSE)UnitedLinuxVMware Virtualization SoftwareNOTE: For a more comple

Comentários a estes Manuais

Sem comentários