HP 538274-421 Ficha Técnica

Consulte online ou descarregue Ficha Técnica para Servidores HP 538274-421. HP ProLiant DL165 G6 2435 2.6GHz Six Core Hot Plug Rack Server Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 34
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Hot Plug SAS/SATA or Non-Hot Plug SATA Models
Hot Plug SAS/SATA or Non-Hot Plug SATA ModelsHot Plug SAS/SATA or Non-Hot Plug SATA Models
Hot Plug SAS/SATA or Non-Hot Plug SATA Models
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Access panel
1.
Power supply cable socket
2.
Memory banks
2.
PS/2 mouse port
3.
Two (2) AMD Opteron 2400 series processors
3.
PS/2 keyboard port
4.
Power supply
4.
Two (2) RJ45 GbE LAN ports
5.
Low-profile PCI-Express or PCI-X slot
5.
Rear panel USB 2.0 ports
6.
System fans
6.
Lights-Out 100 10/100Mbps port
7.
Optical drive bay
7.
Video port
8.
Front-panel USB 2.0 ports
8.
Serial port
9.
Power switch/system status LEDs
9.
Low-profile riser board assembly slot cover
10.
Optional 3rd and 4th 3.5" hot-plug SAS/SATA or non-hot
plug SATA hard drive bays
10.
Full-sized riser board assembly slot cover
11.
Standard 1st and 2nd 3.5" hot-plug SAS/SATA or non-hot
plug SATA hard drive bays
12.
Full height/full length PCI-Express or HTX slot
At A Glance
At A GlanceAt A Glance
At A Glance
Introducing the HP ProLiant DL165G6, now available with the latest high performance Opteron Six Core processors and a new high
efficiency power supply.
Processors
ProcessorsProcessors
Processors
:
Supports up to two AMD Opteron™ 2400 series Six-Core processors
Supports DirectConnect Architecture
Supports Power Now
Memory
MemoryMemory
Memory
:
8 DIMM slots supporting up to 32GB REG PC2-6400 DDR2-800 MHz memory with Advanced ECC
8 DIMM slots supporting up to 64GB REG PC2-5300 DDR2-667 MHz memory with Advanced ECC
Internal Drive Support
Internal Drive SupportInternal Drive Support
Internal Drive Support
:
Internal storage capacity:
SATA Capacity: Support for up to 4.0TB (4 x 1TB) with Hot Plug Model. 3.0TB (4 x 750GB) with Non Hot Plug
Model
SAS Capacity: Support for up to 4.0 TB (4 x 1TB) with Hot Plug Model
NOTE:
NOTE:NOTE:
NOTE:
Installation of the Hot Plug Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth
QuickSpecs
HP ProLiant DL165 Generation 6 (G6)
HP ProLiant DL165 Generation 6 (G6)HP ProLiant DL165 Generation 6 (G6)
HP ProLiant DL165 Generation 6 (G6)
Overview
DA - 13367 Worldwide — Version 2 — June 5, 2009
Page 1
Vista de página 0
1 2 3 4 5 6 ... 33 34

Resumo do Conteúdo

Página 1 - QuickSpecs

Hot Plug SAS/SATA or Non-Hot Plug SATA ModelsHot Plug SAS/SATA or Non-Hot Plug SATA ModelsHot Plug SAS/SATA or Non-Hot Plug SATA ModelsHot Plug SAS/SA

Página 2

NOTE:NOTE:NOTE:NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL165 G6 under the Cluster Platformproduct portf

Página 3

Hot Plug Serial ATA (SATA)/Serial Attached SCSI (SAS) ModelsHot Plug Serial ATA (SATA)/Serial Attached SCSI (SAS) ModelsHot Plug Serial ATA (SATA)/Ser

Página 4

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Página 5

MemoryMemoryMemoryMemory2 GB REG PC2-6400 2 x 1 GB Kit497763-B214 GB REG PC2-6400 2 x 2 GB Kit497765-B218 GB REG PC2-6400 2 x 4 GB Kit497767-B218 GB R

Página 6

ProcessorProcessorProcessorProcessorAMD Opteron™ processor Model 2435 (2.6 GHz,75W ACP)572221-B21AMD Opteron™ processor Model 2431 (2.4 GHz, 75W ACP)5

Página 7

HP 146GB 3G SAS 15K 3.5" DP ENT HDD384854-B21HP 72GB 3G SAS 15K 3.5" DP ENT HDD384852-B21SAS Hot Plug 3.5" Midline (MDL) DrivesSAS Hot

Página 8

Server ManagementServer ManagementServer ManagementServer ManagementStand Alone SoftwareStand Alone SoftwareStand Alone SoftwareStand Alone SoftwarePr

Página 9

Storage ControllersStorage ControllersStorage ControllersStorage ControllersNOTE:NOTE:NOTE:NOTE: The addition of storage controllers for internal hard

Página 10

HPC Specific OptionsHPC Specific OptionsHPC Specific OptionsHPC Specific OptionsHP IB 4X DDR PCI-e Dual Port HCA448397-B21HP IB 4X DDR PCI-e Dual Port

Página 11

Tape AutoloadersTape AutoloadersTape AutoloadersTape AutoloadersHP StorageWorks 1/8 G2 Tape AutoloaderHP StorageWorks 1/8 G2 Tape AutoloaderHP Storage

Página 12

Hard Drives for Hot Plug models only.Network ControllerNetwork ControllerNetwork ControllerNetwork Controller:Embedded NC7782 dual-port gigabit server

Página 13

NOTE:NOTE:NOTE:NOTE: The above is not a complete list of all HP Serviceguard for Linux productnumbers. For a detailed list of supported configuration/

Página 14

HP StorageWorks 60HP StorageWorks 60HP StorageWorks 60HP StorageWorks 60Modular Smart ArrayModular Smart ArrayModular Smart ArrayModular Smart ArrayHP

Página 15

HP Rack 10000 G2HP Rack 10000 G2HP Rack 10000 G2HP Rack 10000 G2SeriesSeriesSeriesSeries(Carbon/GraphiteMetallic)10642 G2 (42U) Rack Cabinet 1200mm De

Página 16

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL165 G6 (all models)HP ProLiant D

Página 17

1-4Non-hot plug 3.5" SATA or Hot-plug SAS/SATA harddrive baysAOptional DVD-ROM, or DVD/CD RWDrive SupportDrive SupportDrive SupportDrive SupportR

Página 18

750GB 1.5G SATA 7.2K500GB 1.5G SATA 7.2K250GB 1.5G SATA 7.2K160GB 1.5G SATA 7.2KUp to 41-4HP P212 Smart Array ControllerHP P410 Smart Array Controller

Página 19

HP StorageWorks USBHP StorageWorks USBHP StorageWorks USBHP StorageWorks USBTape Drives, ExternalTape Drives, ExternalTape Drives, ExternalTape Drives

Página 20

HP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DBackup SystemsBackup SystemsBackup SystemsBackup SystemsD2D120D2D130D2D250

Página 21

HP 500W Power SupplyHP 500W Power SupplyHP 500W Power SupplyHP 500W Power SupplyPart Number - AC 500W PSUPart Number - AC 500W PSUPart Number - AC 500

Página 22

PowerPowerPowerPower ProLiant DL165 G6 Fully Configured115V/60Hz 220V/50HzFully Loaded System Input Wattage (W)568 556Fully Loaded System Input Curr

Página 23

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Página 24

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions(H x W x D)(with bezel)1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.

Página 25

Power SpecificationsPower SpecificationsPower SpecificationsPower SpecificationsTo review typical system power ratings use the Power Advisor which isa

Página 26

(EMC)(EMC)(EMC)(EMC)Normative StandardsNormative StandardsNormative StandardsNormative StandardsCISPR 22; EN55022; EN55024; FCC CFR 47,Pt 15; ICES-003

Página 27

HP 4 Internal Port SASHP 4 Internal Port SASHP 4 Internal Port SASHP 4 Internal Port SASHBA with RAIDHBA with RAIDHBA with RAIDHBA with RAIDDrives Sup

Página 28

© Copyright 2009 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows N

Página 29

Storage ControllerStorage ControllerStorage ControllerStorage ControllerNon-Hot Plug SATAHP Embedded SATA ControllerHot Plug SATA/SASHP Smart Array P2

Página 30

Server ManagementServer ManagementServer ManagementServer ManagementStand Alone SoftwareStand Alone SoftwareStand Alone SoftwareStand Alone SoftwarePr

Página 31

HP Serviceguard for LinuxHP Serviceguard for LinuxHP Serviceguard for LinuxHP Serviceguard for Linux(SGLX)(SGLX)(SGLX)(SGLX)HP Serviceguard for Linux

Página 32

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI V2.0 CompliantPCI 2.2 CompliantPXE Su

Página 33

Operating Systems andOperating Systems andOperating Systems andOperating Systems andVirtualization SoftwareVirtualization SoftwareVirtualization Softw

Página 34

HP EnterpriseHP EnterpriseHP EnterpriseHP EnterpriseConfiguratorConfiguratorConfiguratorConfiguratorThe HP eConfigure Enterprise Configurator now prov

Comentários a estes Manuais

Sem comentários