Hp GS80 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Computadores Hp GS80. HP GS80 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 41
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1.
Operator control panel
2.
One optional PCI or StorageWorks drawer
3.
Standard 14-slot PCI I/O Master Drawer
4.
System drawers each with 1 QBB (Model 4 includes 1 drawer
with space reserved for 2nd drawer; Model 8 includes 2
drawers)
5.
48-volt DC power shelves, 2 power supplies per shelf (Model 4
includes 1 shelf; Model 8 includes 2 shelves)
6.
AC input controller(s)
At A Glance
At A GlanceAt A Glance
At A Glance
AlphaServer GS80 systems include:
One 1224-MHz CPU module; up to eight 1224-MHz Alpha 21264 processors are supported
Optional HP Capacity on Demand (CoD) SMP processors for non-disruptive performance growth
16-MB on-board cache per processor
Advanced crossbar switch with 7-GB/s of memory bandwidth per building block; up to 14-GB/s memory bandwidth per system
Up to 64-GB memory
Up to 16 64-bit PCI buses with 3.2-GB/s aggregate I/O bandwidth
PCI I/O master drawer with 12 configurable PCI slots
PCI dual 10/100 Mbit dual Ethernet adapter
18.2-GB SCSI disk drive
600-MB CD-ROM drive
Enhanced reliability with ECC-protected memory, processor cache, and system data paths
Security of RAID storage and online add and removal of CPUs
Optional redundant power supplies with N+1 power option (hot-swappable processors are available on GS160 and GS320 models)
Up to 56 64-bit PCI slots supported
Tru64 UNIX or OpenVMS factory installed software (FIS); optional high availability support with Tru64 UNIX and OpenVMS cluster solutions
Product warranty, one-year hardware, on-site next business day
QuickSpecs
HP AlphaServer GS80 (1224 MHz)
Overview
DA - 11422 North America — Version 7 — August 19, 2003
Page 1
Vista de página 0
1 2 3 4 5 6 ... 40 41

Resumo do Conteúdo

Página 1 - QuickSpecs

1.Operator control panel 2.One optional PCI or StorageWorks drawer 3.Standard 14-slot PCI I/O Master Drawer 4.System drawers each with 1 QBB (Model

Página 2

Power Option forPower Option forPower Option forPower Option forDS-SL13R-xx ShelvesDS-SL13R-xx ShelvesDS-SL13R-xx ShelvesDS-SL13R-xx ShelvesAdditional

Página 3

Step 6c - External Expansion CabinetsStep 6c - External Expansion CabinetsStep 6c - External Expansion CabinetsStep 6c - External Expansion CabinetsAd

Página 4

Step 7 - StorageStep 7 - StorageStep 7 - StorageStep 7 - StorageStep 7a - Storage Adapters and ControllersStep 7a - Storage Adapters and ControllersSt

Página 5

PCI 1-port Ultra 2 (LVD) SCSI adapter, 32-bit, single-channel (uses one PCIslot); includes external 68-pin HD connectors; requires BN38C-xx cable toco

Página 6

CI AdaptersCI AdaptersCI AdaptersCI Adapters(OpenVMS only)PCI CI adapter, maximum 26 per system or hardware partition (12 per drawer, six per PCI draw

Página 7

5U Rackmount Tape Drive5U Rackmount Tape Drive5U Rackmount Tape Drive5U Rackmount Tape DriveEnclosureEnclosureEnclosureEnclosure (Requires 3X-KZPCA-AA

Página 8

DAT Hot-plug Tape DriveDAT Hot-plug Tape DriveDAT Hot-plug Tape DriveDAT Hot-plug Tape DriveDAT 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses

Página 9

StorageWorksStorageWorksStorageWorksStorageWorksMSL5052SL SDLTMSL5052SL SDLTMSL5052SL SDLTMSL5052SL SDLT110/220-GB Tape Library110/220-GB Tape Library

Página 10

HSV110 Enterprise VirtualHSV110 Enterprise VirtualHSV110 Enterprise VirtualHSV110 Enterprise VirtualStorage Array 5000Storage Array 5000Storage Array

Página 11

EVA 3000 SAN SolutionEVA 3000 SAN SolutionEVA 3000 SAN SolutionEVA 3000 SAN SolutionKitsKitsKitsKitsTru64 UNIX SAN Solutions Kit for Enterprise Virtua

Página 12

ProcessorProcessorProcessorProcessorUp to eight Alpha 21264 6/1224-MHz CPUs (one CPU per module)Cache MemoryCache MemoryCache MemoryCache Memory64-K I

Página 13

McData 64-port FibreMcData 64-port FibreMcData 64-port FibreMcData 64-port FibreChannel SAN DirectorChannel SAN DirectorChannel SAN DirectorChannel SA

Página 14

Maximum # SupportedMaximum # SupportedMaximum # SupportedMaximum # Supported Tru64 UNIXTru64 UNIXTru64 UNIXTru64 UNIXOpenVMSOpenVMSOpenVMSOpenVMS P

Página 15

Gigabit Ethernet AdapterGigabit Ethernet AdapterGigabit Ethernet AdapterGigabit Ethernet Adapter For maximum performance, HP recommends co

Página 16

Step 9 - MEMORY CHANNELStep 9 - MEMORY CHANNELStep 9 - MEMORY CHANNELStep 9 - MEMORY CHANNELUp to two PCI System Area Network controllers supported on

Página 17

MEMORY CHANNELMEMORY CHANNELMEMORY CHANNELMEMORY CHANNELControllerControllerControllerControllerPCI System Area Network controller, maximum two per sy

Página 18

Step 10 - System Console SupportStep 10 - System Console SupportStep 10 - System Console SupportStep 10 - System Console SupportSystem ManagementSyste

Página 19

System ManagementSystem ManagementSystem ManagementSystem ManagementConsole - ModemConsole - ModemConsole - ModemConsole - ModemLocalization KitsLocal

Página 20

Step 12 - Monitors, Keyboards, MouseStep 12 - Monitors, Keyboards, MouseStep 12 - Monitors, Keyboards, MouseStep 12 - Monitors, Keyboards, MouseGraphi

Página 21

Carbon/Silver Flat PanelCarbon/Silver Flat PanelCarbon/Silver Flat PanelCarbon/Silver Flat PanelMonitorsMonitorsMonitorsMonitorsTFT1825, 18-inch (18-i

Página 22

OpalOpalOpalOpalCarbonCarbonCarbonCarbonKeyboard/LanguageKeyboard/LanguageKeyboard/LanguageKeyboard/LanguageOpenVMSOpenVMSOpenVMSOpenVMSTru64 UNIXTru6

Página 23

OS SupportOS SupportOS SupportOS SupportTru64 UNIX systems include preinstalled software, Base license, Unlimited User license, Server Extension licen

Página 24

Step 13 - System SoftwareStep 13 - System SoftwareStep 13 - System SoftwareStep 13 - System SoftwareMedia and documentation required for first system

Página 25

OpenVMSOpenVMSOpenVMSOpenVMSOpenVMS system base packages include Base license and HP Enterprise Integration Server for OpenVMS LicensePackage Revision

Página 26

OpenVMS GalaxyOpenVMS GalaxyOpenVMS GalaxyOpenVMS GalaxyOpenVMS GalaxyOpenVMS GalaxyOpenVMS GalaxyOpenVMS GalaxyLicensing RequirementsLicensing Requir

Página 27

Program Features – Principal ServerProgram Features – Principal ServerProgram Features – Principal ServerProgram Features – Principal Server HP Suppor

Página 28

Model/HPModel/HPModel/HPModel/HPCare PackCare PackCare PackCare PackServicesServicesServicesServicesPrincipal ServerPrincipal ServerPrincipal ServerPr

Página 29

Basic Integration ServiceBasic Integration ServiceBasic Integration ServiceBasic Integration ServiceSystems integration and delivery services related

Página 30

Full CustomFull CustomFull CustomFull CustomConfigurationsConfigurationsConfigurationsConfigurationsThe Integration Service Packages address the most-

Página 31

AlphaServer GS80 System Hardware ExpansionAlphaServer GS80 System Hardware ExpansionAlphaServer GS80 System Hardware ExpansionAlphaServer GS80 System

Página 32

Global Clock ModuleGlobal Clock ModuleGlobal Clock ModuleGlobal Clock ModuleUpgradeUpgradeUpgradeUpgradeAlphaServer GS80 2-port 9.0ns global clock mod

Página 33

GS80 Model 4GS80 Model 4GS80 Model 4GS80 Model 4 GS80 Model 8GS80 Model 8GS80 Model 8GS80 Model 8 DimensionsDimensionsDimensionsDimensions(H x W x

Página 34

Step 1 - Assess Application RequirementsStep 1 - Assess Application RequirementsStep 1 - Assess Application RequirementsStep 1 - Assess Application Re

Página 35

Power RequirementsPower RequirementsPower RequirementsPower RequirementsNOTE: NOTE: NOTE: NOTE: Power system provides near unity power factor that all

Página 36

ClearancesClearancesClearancesClearances OperatingOperatingOperatingOperatingServiceServiceServiceService FrontFrontFrontFront29.5 in (75 cm) 29.5 in

Página 37

AlphaServer GS80 (1224-MHz) Base SystemsAlphaServer GS80 (1224-MHz) Base SystemsAlphaServer GS80 (1224-MHz) Base SystemsAlphaServer GS80 (1224-MHz) Ba

Página 38

Step 4 - Select Memory OptionsStep 4 - Select Memory OptionsStep 4 - Select Memory OptionsStep 4 - Select Memory OptionsMemory options are engineered

Página 39

Memory Application ExamplesMemory Application ExamplesMemory Application ExamplesMemory Application ExamplesConfiguring memory is a compromise between

Página 40

One Alpha 21264 6/1224-MHz CPU moduleOne 3X-MS8AA-BB/CB/DB memory module (1 GB, 2 GB, 4 GB)One 3X-KFWHA-BA system I/O module and one 3X-DWWPA-AA maste

Página 41

Step 6 - Configure Packaging OptionsStep 6 - Configure Packaging OptionsStep 6 - Configure Packaging OptionsStep 6 - Configure Packaging OptionsStep 6

Comentários a estes Manuais

Sem comentários