HP Smart Array P431 Controller
User Guide
Abstract
This document includes feature, installation, and configuration information about HP Smart Array Controllers and is for the person who installs,
administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in
recognizing hazards in products with hazardous energy levels.
Part Number: 742341-002
February 2014
Edition: 2
Vista de página 0
1 2 3 4 5 6 ... 45 46

Resumo do Conteúdo

Página 1 - User Guide

HP Smart Array P431 Controller User Guide Abstract This document includes feature, installation, and configuration information about HP Smart Array

Página 2

Specifications 10 Controller features Basic features This HP Smart Array controller has the following basic features: • Supports RAID 0, 1, 10, 1 (

Página 3 - Contents

Specifications 11 HP Secure Encryption HP Secure Encryption is a controller-based, enterprise-class data encryption solution that protects data at r

Página 4 - Contents 4

Specifications 12 Feature Description Time required to recharge battery or capacitor pack 5 minutes or less Duration of battery or capacitor pack b

Página 5 - Component identification

Installation and configuration 13 Installation and configuration Procedures for controllers in a server To install a stand-up controller in a server

Página 6 - Controller LEDs

Installation and configuration 14 3. Verify the server firmware is the latest revision. If necessary, update the server firmware ("Updating fir

Página 7 - Cache module LEDs

Installation and configuration 15 WARNING: To reduce the risk of personal injury or damage to the equipment, consult the safety information and us

Página 8

Installation and configuration 16 Configuration tools HP Smart Storage Administrator HP SSA is the main tool for configuring arrays on HP Smart Arra

Página 9 - Specifications

Installation and configuration 17 UEFI System Utilities At this time, the HP ProLiant DL580 Gen8 Server is the only HP ProLiant Gen8 server that sup

Página 10 - Controller features

Installation and configuration 18 Setting the controller order For servers running in legacy (non-UEFI) mode, use the following procedure to set the

Página 11 - Controller specifications

Installation and configuration 19 System maintenance tools Updating firmware Server and controller firmware should be updated before using the contr

Página 12

© Copyright 2013, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Página 13

Installation and configuration 20 • HP Insight Diagnostics HP Insight Diagnostics is a tool that displays information about the system hardware con

Página 14

Drive procedures 21 Drive procedures Identifying the status of a drive Identifying the status of a legacy drive Identify a legacy drive by its carri

Página 15 - Cable part numbers

Drive procedures 22 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing regularly (1 Hz) Amber, flashing regularly (1 Hz)

Página 16 - Configuration tools

Drive procedures 23 Item LED Status Definition 4 Drive status Solid green The drive is a member of one or more logical drives. Flashing gree

Página 17 - Configuration procedures

Drive procedures 24 Recognizing drive failure (HP SmartDrive) If any of the following occurs, the drive has failed: • The drive status LED illumina

Página 18 - Configuring an array

Drive procedures 25 Compromised fault tolerance CAUTION: When fault tolerance is compromised, data loss can occur. However, it may be possible t

Página 19 - Diagnostic tools

Drive procedures 26 Before replacing drives • Open Systems Insight Manager, and inspect the Error Counter window for each physical drive in the sam

Página 20 - • POST messages

Drive procedures 27 • Failure of a second drive in a RAID 6 configuration Time required for a rebuild The time required for a rebuild varies, depe

Página 21 - Drive procedures

Drive procedures 28 2. Restore data from backup. Writing data to the location of the unreadable sector often eliminates the error. 3. Remove and re

Página 22

Drive procedures 29 When data rebuild on the new drive is complete, the Drive status LED changes from flashing green to solid green. 3. Repeat the

Página 23 - Recognizing drive failure

Contents 3 Contents Component identification ...

Página 24 - Drive procedures 24

Drive procedures 30 o If a 1724 or 1727 POST message appears, drive positions were changed successfully and the configuration was updated. Continue

Página 25 - Replacing drives

Drive procedures 31 When the expansion process has finished, you can use the liberated storage capacity on the enlarged array to create new logical

Página 26 - Before replacing drives

Electrostatic discharge 32 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Página 27 - Time required for a rebuild

Regulatory information 33 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Página 28 - Upgrading drive capacity

Regulatory information 34 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20

Página 29 - Moving drives and arrays

Support and other resources 35 Support and other resources Before you contact HP Be sure to have the following information available before you call

Página 30 - Adding drives

Support and other resources 36 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Página 31 - Drive procedures 31

Support and other resources 37 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Página 32 - Electrostatic discharge

Support and other resources 38 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Página 33 - Regulatory information

Support and other resources 39 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Página 34 - Communications interference

Contents 4 Automatic data recovery (rebuild) ... 26

Página 35 - Support and other resources

Support and other resources 40 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Página 36

Support and other resources 41

Página 37 - Customer Self Repair

Support and other resources 42

Página 38

Acronyms and abbreviations 43 Acronyms and abbreviations ADM Advanced Data Mirroring CSR Customer Self Repair FBWC flash-backed write cache FCC F

Página 39 - Reparo feito pelo cliente

Documentation feedback 44 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Página 40

Index 45 A adding drives 30 array, configuring 18 authorized reseller 35 automatic data recovery (rebuild) 26 B battery replacement notice

Página 41

Index 46 J Japanese notice 33 L LEDs, cache module 7 LEDs, controller 6 LEDs, drive 21 limited warranty 34 load protection guarantee 34

Página 42

Component identification 5 Component identification Controller components For cabling configuration and troubleshooting purposes, connector names ar

Página 43 - Acronyms and abbreviations

Component identification 6 Controller LEDs Immediately after you power up the server, the controller runtime LEDs illuminate briefly in a predetermi

Página 44 - Documentation feedback

Component identification 7 Item Color Name Interpretation the Managed/Active cable. 3 Amber Debug On = Controller is in reset. Off = Controller

Página 45 - Index 45

Component identification 8 1 - Amber 2 - Green 3 - Green Interpretation Off Flashing once every 2 seconds Flashing once every 2 seconds The cache

Página 46 - Index 46

Specifications 9 Specifications Memory and storage capacity conventions Memory capacities are specified using binary prefixes: • KiB = 210 bytes •