Troubleshooting
Item Symptom Probable
Cause
Remedy
1
Server and/or
Network LEDs not
illuminated.
Unit is in
Bypass mode.
Improper
cabling.
If the Inline LED is not illuminated
(solid or blinking) take the SA7100/
SA7120 out of Bypass mode by
either pressing the Bypass switch on
the units front panel or using the
CLIs inline command.
Depending on what type of
equipment the SA7100/SA7120 is
connected to, either straight-through
or crossover Cat-5 network cables
are required for both Network and
Server ports. Switch out the
different cable types at each port
until both Network and Server LEDs
are illuminated.