Página 1 - HP ProLiant Network Adapter

HP ProLiant Network Adapter Software and Configuration Guide Part Number 441877-00J November 2008 (Nineth Edition)

Página 2 - Intended audience

Installation 10 Installation Downloading the SoftPaq files 1. Go to the HP website (http://www.hp.com). 2. Click Software & Driver Downloads fr

Página 3 - Contents

Configuration and diagnostics 11 Configuration and diagnostics Configuring adapters using operating system software The following sections describe

Página 4 - Contents 4

Configuration and diagnostics 12 o Range = None; Magic Packet; Wake up Frame; Both • Flow Control. The Flow Control property allows the user to ena

Página 5 - Overview

Configuration and diagnostics 13 system memory used by the driver. If too few receive descriptors are used, performance suffers. If too many receive

Página 6 - Overview 6

Configuration and diagnostics 14 o 2500 Mb. To achieve speeds of 2.5 Gbps, update to the latest firmware and then set the link partner (switch or hu

Página 7 - Windows 2008 drivers

Configuration and diagnostics 15 • IPv4 Checksum Offload. Describes whether the device enabled or disabled the calculation of IPv4 checksums. o Tx

Página 8 - Windows 2003 x64 drivers

Configuration and diagnostics 16 • TCP Offload Engine (TOE). Enables the offloading of TCP connections to HP Multifunction Server Adapters. Microso

Página 9 - Overview 9

Configuration and diagnostics 17 Parameter Options Description PDriver = Default = OFF Selections are: OFF, ON Allows driver to operate in persist

Página 10 - Installation

Configuration and diagnostics 18 Parameter Options Description RxTicks= Default = 360 Min = 0, disabled Max = 5000000, 5 seconds Units are in m

Página 11 - Server 2008 x64

Configuration and diagnostics 19 set Default Time Server Type = SINGLE set Bindery Context = O=LAN # WARNING!! file server name NOVELLSERVER51 # WA

Página 12

© Copyright 2005, 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Página 13

Configuration and diagnostics 20 default to half-duplex. You must have an auto-negotiating switch/hub (an Nway switch) to get full-duplex support wi

Página 14 - Server 2003 x64

Configuration and diagnostics 21 Where n = Ethernet_802.2, Ethernet_802.3, Ethernet_II, Ethernet_SNAP o Default = Ethernet_802.2 • POLL. This keyw

Página 15

Configuration and diagnostics 22 o Syntax: commit [team=nnn] o Description: Sets a certain mode. Use after binding to base drivers with Team=nnn. •

Página 16

Configuration and diagnostics 23 o Description: Changes probe retries check interval • PROBE_RETRY_COUNT o Syntax: probe_retry_count=nnn o Descri

Página 17

Configuration and diagnostics 24 o Syntax: team=nnnn o Description: Identifies the team. nnnn=DecimalNumber. • TX_ECBS_TO_USE o Syntax: tx_ecbs_t

Página 18

Configuration and diagnostics 25 o Address test: Writes each address with unique increment data. Reads back data to ensure data is correct. After fi

Página 19

Configuration and diagnostics 26 • This tests both high and low priorities DMA. It moves data from host memory to adapter SRAM, verifies data, and

Página 20

Configuration and diagnostics 27 • Invalid adapter device • Read only bit %s got changed after writing zero at offset 0x%X • Read only bit %s got

Página 21

Configuration and diagnostics 28 • %d bad packets have been received • %c%d is an invalid Test • EEPROM checksum error • Error in reading WOL/PX

Página 22

Configuration and diagnostics 29 • *1 Internal Use. Program will not generate this error. HP NC-Series Broadcom 10 GbE adapter diagnostics The eDi

Página 23

Contents 3 Contents Overview...

Página 24

Configuration and diagnostics 30 Options Description -wol <1|0>. Enable (1) / Disable(0) magic packet Wake-on-LAN option. -mba <1|0> E

Página 25

Configuration and diagnostics 31 The following return codes are the available upon exit of the eDiag utility. The return codes are backward compatib

Página 26

Configuration and diagnostics 32 Return Code Value Description ERR_PRG_MFW 61 Fail to program IPMI/UMP firmware ERR_PRG_MBA 62 Fail to program

Página 27

Configuration and diagnostics 33 Return Code Value Description ERR_REG_TCM_TEST 118 TCM Register test fails ERR_REG_TM_TEST 119 TM Register te

Página 28

Configuration and diagnostics 34 Return Code Value Description ERR_MEM_XSDM_TEST 157 XSDM Memory test fails ERR_MEM_XSEM_TEST 158 XSEM Memory

Página 29

Configuration and diagnostics 35 Return Code Value Description ERR_PRG_IB 195 Fail to program iSCSI boot image HP NC-Series Broadcom Multifunc

Página 30 - Return Codes

Configuration and diagnostics 36 • B5. CP scratchpad • B6. MCP scratchpad • B7. TAS header buffer • B8. TAS payload buffer • B9. RBUF via GRC

Página 31

Configuration and diagnostics 37 This tests the internal DMA engine by performing both DMA reads and writes at various location and various sizes. C

Página 32

Configuration and diagnostics 38 The ccfwupg1.bat command upgrades the Boot Code and Option ROM firmware image on the following c-Class Multifunctio

Página 33

Configuration and diagnostics 39 Using the -S option the user can optionally select the non-interactive mode, which causes the firmware to automatic

Página 34

Contents 4

Página 35

Configuration and diagnostics 40 Property Parameter Max Jumbo Buffers Specifies the number of 8K (jumbo) buffers for receive, in addition to the st

Página 36

Configuration and diagnostics 41 Property Parameter Vlan Id Sets the VLAN ID for this interface (also exposed through the standard OID). QoS Packet

Página 37 - BladeSystem

Configuration and diagnostics 42 HP NC-Series NetXen Online Firmware Upgrade Utility The HP NC-Series NetXen Online Firmware Upgrade Utility for Win

Página 38 - Utility

Configuration and diagnostics 43 Command Definition Description -a, --all Update all of firmware Updates the flash memory using appropriate romimag

Página 39 - HP NC-Series NetXen adapters

Configuration and diagnostics 44 1. Execute the following command to enable PXE functionality: nxflash -i eth<#> --opt-rom-on 2. Execute the

Página 40

Configuration and diagnostics 45 o Default = Auto Detect o Range = Auto Detect; Force Master Mode; Force Slave Mode • Interrupt moderation. If ena

Página 41

Configuration and diagnostics 46 o Range = Disabled; Enabled • Priority and VLAN. Enables or disables the ability to insert or remove the 802.1q ta

Página 42

Configuration and diagnostics 47 • Wake On Settings. Available only when Enable PME is enabled. Allows you to choose what types of packets will cau

Página 43

Configuration and diagnostics 48 • Number of Receive Descriptors. Specifies the number of buffers used by the driver when copying data to the proto

Página 44 - HP NC-Series Intel Adapters

Configuration and diagnostics 49 o Range = Disabled; Enabled; Hardware Default; No Action (NC110x, NC360x, NC364x = OS Controlled, Disabled, Enabled

Página 45

Overview 5 Overview Supported adapters and operating systems The following is a list of HP NC-Series adapters that are supported on HP ProLiant serve

Página 46

Configuration and diagnostics 50 • Number of test passes—This option determines how many times a test runs. While the test is running, the informat

Página 47

Configuration and diagnostics 51 Adapter properties and configurations on Netware A network device driver must be installed before the Gigabit Ether

Página 48

Configuration and diagnostics 52 Parameter Options Description TxDescriptors = Default = 200 Recommended Min = 100 Max = 512 Min = 1 when used wit

Página 49

Configuration and diagnostics 53 three times the minimum packet receive buffers. Typically one MB of RAM is required per 1000 receive buffers. In t

Página 50

Configuration and diagnostics 54 LOAD Q57 SLOT=2 FRAME=Ethernet_SNAP NAME=Q57_1_ESP BIND IPX Q57_1_ESP NET=477A35BD LOAD Q57 SLOT=2 FRAME=Ethernet_I

Página 51

Configuration and diagnostics 55 o Default = auto-negotiate o Examples: 100 Mbps full-duplex FORCEDUPLEX=2 SPEED=100 10 Mbps full-duplex FORCEDUPLE

Página 52

Configuration and diagnostics 56 0—Driver operates in normal mode 1—Driver operates to reduce the number of spurious interrupts o Default = 1 N

Página 53

Configuration and diagnostics 57 • LBN o Syntax: Reset LBN=nnn o Example: cpqans reset lbn=nnn o Description: Resets the logical board number (

Página 54

Configuration and diagnostics 58 o Syntax: probes=[BROADCAST|MULTICAST] o Description: Changes probes addressing • RECOMMIT o Syntax: recommit [t

Página 55

Configuration and diagnostics 59 • Compliance with the Pre-boot eXecution Environment (PXE) Version 2.1 Specification • Remote Program Load (RPL)

Página 56

Overview 6 • HP NC325i PCI Express Dual Port Gigabit Server Adapter • HP NC326i PCI Express Dual Port Gigabit Server Adapter • HP NC370i PCI-X Mul

Página 57

Configuration and diagnostics 60 within the allowed number of seconds, reboot the computer to try again. If you select a Setup Menu Wait Time settin

Página 58 - Boot Agent

Configuration and diagnostics 61 Configuration settings Possible values Description Show Setup Prompt • Enabled • Disabled Controls whether or no

Página 59

Configuration and diagnostics 62 Use IBAUtil to enable or disable WOL or Boot Agent features. To obtain this utility download the HP ProLiant Networ

Página 60

Configuration and diagnostics 63 Parameter Description -UP, -UPGRADE or -INSTALL -UP: Programs an Intel Boot Agent image into the FLASH on the sel

Página 61

Configuration and diagnostics 64 • 1–Operator termination • 2–Invalid adapter • 3–Bad command line parameter • 4–EEPROM checksum failure • 5–E

Página 62

Configuration and diagnostics 65 attempt to remote boot. If this error persists, try updating your system's BIOS to the most-recent version. Co

Página 63 - • 0–Success

Configuration and diagnostics 66 The adapter does not detect link. Be sure that the cable is good and is attached to a working hub or switch. The li

Página 64

Configuration and diagnostics 67 After the Boot Agent product has finished its sole task (remote booting), it no longer has any effect on the client

Página 65

Configuration and diagnostics 68 Anytime the Configuration Setup Menu is displayed (refer to the "Configuring the Boot Agent in a pre-boot PXE

Página 66

Configuration and diagnostics 69 recommended selection is Off and it is the default setting. To disable Flow Control, select Off from the Value list

Página 67

Overview 7 • NetWare Open Enterprise Server Linux 32 • Red Hat Enterprise Linux 5 • Red Hat Enterprise Linux 4 • Red Hat Enterprise Linux 3 • S

Página 68

Configuration and diagnostics 70 To enable the Gigabit Ethernet adapter to function correctly, you need to install the latest support pack files. Th

Página 69

Configuration and diagnostics 71 Parameter Options Description Slot = n Identifies the slot number for the specific adapter currently being confi

Página 70

Configuration and diagnostics 72 • set minimum packet receive buffers = 10000 • set maximum physical receive packet size = 2048 Verifying or modif

Página 71

Configuration and diagnostics 73 To remove the drivers from the Autoexec.ncf, locate the LOAD and BIND command lines associated with the driver and

Página 72

Configuration and diagnostics 74 • SPEED. This keyword specifies the speed the driver uses. If you do not use this parameter, the driver automatica

Página 73

Configuration and diagnostics 75 Where n = 0 or 1 0—Does not offload Rx Checksum verification to the adapter 1—Offloads Rx Checksum verification to

Página 74

Configuration and diagnostics 76 o Syntax: mode=[NFT | ALB | FEC | GEC | 802.3AD] • NAME o Syntax: name=[any unique name] o Description: Sets a u

Página 75

Configuration and diagnostics 77 o Syntax: RemoveVlanID=nnn o Description: Removes the selected VLAN • RESET o Syntax: RESET LBN=nnn o Descript

Página 76

Technical support 78 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su

Página 77

Technical support 79 • For downloadable support software for HP Digital Networking Products, Hubs, Integrated Access Devices, Modems and ISDN, Adap

Página 78 - Technical support

Overview 8 • N1G60i32.sys for NC310xx, NC340x, NC61xx, and NC71xx server adapters • Q57ND60X.sys for NC105x, NC107x, NC10xx, NC150x, NC32xx, NC10x

Página 79 - Technical support 79

Acronyms and abbreviations 80 Acronyms and abbreviations BIOS Basic Input/Output System DHCP Dynamic Host Configuration Protocol IPL initial progr

Página 80 - Acronyms and abbreviations

Acronyms and abbreviations 81 UNDI Universal Network Driver Interface

Página 81

Index 82 B Boot Agent 58 D driver and software information 7 F firmware upgrade 38, 42 I installation 10 P properties 14, 68 PXE configurat