Installation 10 Installation Downloading the SoftPaq files 1. Go to the HP website (http://www.hp.com). 2. Click Software & Driver Downloads fr
Configuration and diagnostics 11 Configuration and diagnostics Configuring adapters using operating system software The following sections describe
Configuration and diagnostics 12 o Range = None; Magic Packet; Wake up Frame; Both • Flow Control. The Flow Control property allows the user to ena
Configuration and diagnostics 13 system memory used by the driver. If too few receive descriptors are used, performance suffers. If too many receive
Configuration and diagnostics 14 o 2500 Mb. To achieve speeds of 2.5 Gbps, update to the latest firmware and then set the link partner (switch or hu
Configuration and diagnostics 15 • IPv4 Checksum Offload. Describes whether the device enabled or disabled the calculation of IPv4 checksums. o Tx
Configuration and diagnostics 16 • TCP Offload Engine (TOE). Enables the offloading of TCP connections to HP Multifunction Server Adapters. Microso
Configuration and diagnostics 17 Parameter Options Description PDriver = Default = OFF Selections are: OFF, ON Allows driver to operate in persist
Configuration and diagnostics 18 Parameter Options Description RxTicks= Default = 360 Min = 0, disabled Max = 5000000, 5 seconds Units are in m
Configuration and diagnostics 19 set Default Time Server Type = SINGLE set Bindery Context = O=LAN # WARNING!! file server name NOVELLSERVER51 # WA
© Copyright 2005, 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr
Configuration and diagnostics 20 default to half-duplex. You must have an auto-negotiating switch/hub (an Nway switch) to get full-duplex support wi
Configuration and diagnostics 21 Where n = Ethernet_802.2, Ethernet_802.3, Ethernet_II, Ethernet_SNAP o Default = Ethernet_802.2 • POLL. This keyw
Configuration and diagnostics 22 o Syntax: commit [team=nnn] o Description: Sets a certain mode. Use after binding to base drivers with Team=nnn. •
Configuration and diagnostics 23 o Description: Changes probe retries check interval • PROBE_RETRY_COUNT o Syntax: probe_retry_count=nnn o Descri
Configuration and diagnostics 24 o Syntax: team=nnnn o Description: Identifies the team. nnnn=DecimalNumber. • TX_ECBS_TO_USE o Syntax: tx_ecbs_t
Configuration and diagnostics 25 o Address test: Writes each address with unique increment data. Reads back data to ensure data is correct. After fi
Configuration and diagnostics 26 • This tests both high and low priorities DMA. It moves data from host memory to adapter SRAM, verifies data, and
Configuration and diagnostics 27 • Invalid adapter device • Read only bit %s got changed after writing zero at offset 0x%X • Read only bit %s got
Configuration and diagnostics 28 • %d bad packets have been received • %c%d is an invalid Test • EEPROM checksum error • Error in reading WOL/PX
Configuration and diagnostics 29 • *1 Internal Use. Program will not generate this error. HP NC-Series Broadcom 10 GbE adapter diagnostics The eDi
Contents 3 Contents Overview...
Configuration and diagnostics 30 Options Description -wol <1|0>. Enable (1) / Disable(0) magic packet Wake-on-LAN option. -mba <1|0> E
Configuration and diagnostics 31 The following return codes are the available upon exit of the eDiag utility. The return codes are backward compatib
Configuration and diagnostics 32 Return Code Value Description ERR_PRG_MFW 61 Fail to program IPMI/UMP firmware ERR_PRG_MBA 62 Fail to program
Configuration and diagnostics 33 Return Code Value Description ERR_REG_TCM_TEST 118 TCM Register test fails ERR_REG_TM_TEST 119 TM Register te
Configuration and diagnostics 34 Return Code Value Description ERR_MEM_XSDM_TEST 157 XSDM Memory test fails ERR_MEM_XSEM_TEST 158 XSEM Memory
Configuration and diagnostics 35 Return Code Value Description ERR_PRG_IB 195 Fail to program iSCSI boot image HP NC-Series Broadcom Multifunc
Configuration and diagnostics 36 • B5. CP scratchpad • B6. MCP scratchpad • B7. TAS header buffer • B8. TAS payload buffer • B9. RBUF via GRC
Configuration and diagnostics 37 This tests the internal DMA engine by performing both DMA reads and writes at various location and various sizes. C
Configuration and diagnostics 38 The ccfwupg1.bat command upgrades the Boot Code and Option ROM firmware image on the following c-Class Multifunctio
Configuration and diagnostics 39 Using the -S option the user can optionally select the non-interactive mode, which causes the firmware to automatic
Contents 4
Configuration and diagnostics 40 Property Parameter Max Jumbo Buffers Specifies the number of 8K (jumbo) buffers for receive, in addition to the st
Configuration and diagnostics 41 Property Parameter Vlan Id Sets the VLAN ID for this interface (also exposed through the standard OID). QoS Packet
Configuration and diagnostics 42 HP NC-Series NetXen Online Firmware Upgrade Utility The HP NC-Series NetXen Online Firmware Upgrade Utility for Win
Configuration and diagnostics 43 Command Definition Description -a, --all Update all of firmware Updates the flash memory using appropriate romimag
Configuration and diagnostics 44 1. Execute the following command to enable PXE functionality: nxflash -i eth<#> --opt-rom-on 2. Execute the
Configuration and diagnostics 45 o Default = Auto Detect o Range = Auto Detect; Force Master Mode; Force Slave Mode • Interrupt moderation. If ena
Configuration and diagnostics 46 o Range = Disabled; Enabled • Priority and VLAN. Enables or disables the ability to insert or remove the 802.1q ta
Configuration and diagnostics 47 • Wake On Settings. Available only when Enable PME is enabled. Allows you to choose what types of packets will cau
Configuration and diagnostics 48 • Number of Receive Descriptors. Specifies the number of buffers used by the driver when copying data to the proto
Configuration and diagnostics 49 o Range = Disabled; Enabled; Hardware Default; No Action (NC110x, NC360x, NC364x = OS Controlled, Disabled, Enabled
Overview 5 Overview Supported adapters and operating systems The following is a list of HP NC-Series adapters that are supported on HP ProLiant serve
Configuration and diagnostics 50 • Number of test passes—This option determines how many times a test runs. While the test is running, the informat
Configuration and diagnostics 51 Adapter properties and configurations on Netware A network device driver must be installed before the Gigabit Ether
Configuration and diagnostics 52 Parameter Options Description TxDescriptors = Default = 200 Recommended Min = 100 Max = 512 Min = 1 when used wit
Configuration and diagnostics 53 three times the minimum packet receive buffers. Typically one MB of RAM is required per 1000 receive buffers. In t
Configuration and diagnostics 54 LOAD Q57 SLOT=2 FRAME=Ethernet_SNAP NAME=Q57_1_ESP BIND IPX Q57_1_ESP NET=477A35BD LOAD Q57 SLOT=2 FRAME=Ethernet_I
Configuration and diagnostics 55 o Default = auto-negotiate o Examples: 100 Mbps full-duplex FORCEDUPLEX=2 SPEED=100 10 Mbps full-duplex FORCEDUPLE
Configuration and diagnostics 56 0—Driver operates in normal mode 1—Driver operates to reduce the number of spurious interrupts o Default = 1 N
Configuration and diagnostics 57 • LBN o Syntax: Reset LBN=nnn o Example: cpqans reset lbn=nnn o Description: Resets the logical board number (
Configuration and diagnostics 58 o Syntax: probes=[BROADCAST|MULTICAST] o Description: Changes probes addressing • RECOMMIT o Syntax: recommit [t
Configuration and diagnostics 59 • Compliance with the Pre-boot eXecution Environment (PXE) Version 2.1 Specification • Remote Program Load (RPL)
Overview 6 • HP NC325i PCI Express Dual Port Gigabit Server Adapter • HP NC326i PCI Express Dual Port Gigabit Server Adapter • HP NC370i PCI-X Mul
Configuration and diagnostics 60 within the allowed number of seconds, reboot the computer to try again. If you select a Setup Menu Wait Time settin
Configuration and diagnostics 61 Configuration settings Possible values Description Show Setup Prompt • Enabled • Disabled Controls whether or no
Configuration and diagnostics 62 Use IBAUtil to enable or disable WOL or Boot Agent features. To obtain this utility download the HP ProLiant Networ
Configuration and diagnostics 63 Parameter Description -UP, -UPGRADE or -INSTALL -UP: Programs an Intel Boot Agent image into the FLASH on the sel
Configuration and diagnostics 64 • 1–Operator termination • 2–Invalid adapter • 3–Bad command line parameter • 4–EEPROM checksum failure • 5–E
Configuration and diagnostics 65 attempt to remote boot. If this error persists, try updating your system's BIOS to the most-recent version. Co
Configuration and diagnostics 66 The adapter does not detect link. Be sure that the cable is good and is attached to a working hub or switch. The li
Configuration and diagnostics 67 After the Boot Agent product has finished its sole task (remote booting), it no longer has any effect on the client
Configuration and diagnostics 68 Anytime the Configuration Setup Menu is displayed (refer to the "Configuring the Boot Agent in a pre-boot PXE
Configuration and diagnostics 69 recommended selection is Off and it is the default setting. To disable Flow Control, select Off from the Value list
Overview 7 • NetWare Open Enterprise Server Linux 32 • Red Hat Enterprise Linux 5 • Red Hat Enterprise Linux 4 • Red Hat Enterprise Linux 3 • S
Configuration and diagnostics 70 To enable the Gigabit Ethernet adapter to function correctly, you need to install the latest support pack files. Th
Configuration and diagnostics 71 Parameter Options Description Slot = n Identifies the slot number for the specific adapter currently being confi
Configuration and diagnostics 72 • set minimum packet receive buffers = 10000 • set maximum physical receive packet size = 2048 Verifying or modif
Configuration and diagnostics 73 To remove the drivers from the Autoexec.ncf, locate the LOAD and BIND command lines associated with the driver and
Configuration and diagnostics 74 • SPEED. This keyword specifies the speed the driver uses. If you do not use this parameter, the driver automatica
Configuration and diagnostics 75 Where n = 0 or 1 0—Does not offload Rx Checksum verification to the adapter 1—Offloads Rx Checksum verification to
Configuration and diagnostics 76 o Syntax: mode=[NFT | ALB | FEC | GEC | 802.3AD] • NAME o Syntax: name=[any unique name] o Description: Sets a u
Configuration and diagnostics 77 o Syntax: RemoveVlanID=nnn o Description: Removes the selected VLAN • RESET o Syntax: RESET LBN=nnn o Descript
Technical support 78 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su
Technical support 79 • For downloadable support software for HP Digital Networking Products, Hubs, Integrated Access Devices, Modems and ISDN, Adap
Overview 8 • N1G60i32.sys for NC310xx, NC340x, NC61xx, and NC71xx server adapters • Q57ND60X.sys for NC105x, NC107x, NC10xx, NC150x, NC32xx, NC10x
Acronyms and abbreviations 80 Acronyms and abbreviations BIOS Basic Input/Output System DHCP Dynamic Host Configuration Protocol IPL initial progr
Acronyms and abbreviations 81 UNDI Universal Network Driver Interface
Index 82 B Boot Agent 58 D driver and software information 7 F firmware upgrade 38, 42 I installation 10 P properties 14, 68 PXE configurat
Overview 9 • NXP2NC64.sys for all NC51xx 10GbE server adapters • BXND52a.sys for all NC532x 10GbE server adapters Components for these drive rs are
Comentários a estes Manuais