HP LX800 Manual de Instalação Página 29

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 86
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 28
The AC power cords (tri-phase and single-phase) have to be screwed to the bottom terminals of the
switch. Add adequate ferrules on power cord cable terminations. In total there are 6 terminals to attach
wires, and only 5 of them are to be used. They are labeled (from left to right): L1, L2, L3, (blank), L0 and
N. Each wire must be securely attached to the terminals of the power switch.
Label on Switch Wire Power Cord
L1 Phase Tri-phase
L2 Phase Tri-phase
L3 Phase Tri-phase
Blank
L0 Phase Single-phase
N Neutral Single-phase
ENWW Tri-phase AC Power Cord 25
Vista de página 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 85 86

Comentários a estes Manuais

Sem comentários