Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of
heat and cold, to ensure that unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the
required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that
they are subject to each other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the
computer. Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust
ventilation must be provided on the enclosure, and the same operating guidelines listed
above will still apply.
Operating: 50° to 95° F (10° to 35° C)*
Non-operating: –22° to 140° F(–30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum
Altitude (unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea
level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be
limited by the type and number of options installed.
300W active PFC
(230 VAC input only)
82/85/82% efficient at
20/50/100% load
(115V)
82/85/82% efficient at
20/50/100% load
(230V)
82/85/82%efficient at
20/50/100% load
(115V)
82/85/82% efficient at
20/50/100% load
(230V)
200 - 240 VAC (300W
active PFC)
Rated Input Current with Energy Efficient* Power Supply