21
NOTE:
Identify the mark on the console port and make sure that you are connecting to the correct port.
Setting terminal parameters
To configure and manage the switch, you must run a terminal emulator program on the console terminal.
The following are the required terminal settings:
Bits per second9,600
Data bits8
ParityNone
Stop bits1
Flow controlNone
EmulationVT100
To set terminal parameters, for example, on a Windows XP HyperTerminal:
1. Select Start > All Programs > Accessories > Communications > HyperTerminal.
The Connection Description dialog box is displayed.
2. Enter the name of the new connection in the Name field and click OK.
Figure 25 Connection description
3. Select the serial port to be used from the Connect using list, and click OK.