© Agilent Technologies 2001–2002 Administering Agilent 3070 UNIX Systems (UNIX 10.X) 4-12
Chapter 4: Restoring System Software
19 Allow the software installation to
proceed to completion.
This can take approximately one hour depending on the speed of the
controller. During the process, the controller will reboot, then more
processing will occur.
CAUTION
✸
During this process, these status indicators will be displayed:
* Download_mini_system: AND
* Loading software
If errors occur after these indicators appear, the tape drive could be
defective (warnings are OK).
20 Remove the disaster recovery tape.
Return it to a safe place!
21 Perform all instructions given in
Chapter 3, Setting-Up New
Systems beginning with Task 3 in
Table 3-2 on page 3-6.
Table 4-1 Recover the system using a disaster-recovery tape
Task Step