Model HP NetServer Rack Storage/12 - D5989B or C
plus two D6025B or two D6025C SCSI cards for each cabinet
Status SCSI ID 5 (fixed)
Disk SCSI IDs 0 – 3, 8 – 15 (fixed)
Disk drives: Same as HP Rack Storage/12FC
Cables Any HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN Client LAN
LAN connection HP D5954A crossover cable or any
equivalent
Any LAN
The intra-cluster LAN may only be
used for cluster node communication
via a crossover cable. It may not be
used for client communication.
NIC:
Model HP D5013B (10/100TX PCI) Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Driver Hptxnt5.sys 4.01.67 (Windows 2000
A.S. CD) or later
For SPOFless, use hptxnt5.sys
version 4.2.27.0 (Navigator L.18.04.5)
or later
Vendor supported driver.
NOTE If the Client and Intra-
cluster LANs are the same model
(D5013A/B), the Client LAN must
use the same driver as the Intra-
cluster LAN.
No. of NICs 1 1 minimum
For SPOFless, 2 NICs configured
as a fault-tolerant team are
recommended.
Shared Storage Cabling
This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LXr 8500,
one HP Rack Storage/12FC and two, optional SCSI HP Rack Storage/12’s. Only these cabling configurations and
these cables are supported.
Vista de página 3