Vista de página 10
AXESS
®
PRO SERIES 3000
LOGIC CONTROL BOARD LAYOUT
03
08
09
10
11
12
13
14
04
05
06
07
01
02
Item
#
“L1” Board “L2” Board
Item Name Function Item Name Function
1
LCD Screen Display screen for menu system LCD Screen Display screen for menu system
2
PG-3 Input Terminal to connect PG-3 Programmer for advanced diagnostics PG-3 Input Terminal to connect PG-3 Programmer for advanced diagnostics
3
V+ Power supply for 3-wire PE Beams (24-30V DC) AUX OUT Auxiliary Output to provide trigger to an external device
4
IN3 Input for 3-Wire PE Beam trigger (N/C) V+ Accessory power supply (24-30V DC)
5
V- Common for 2-wire/Wireless and 3-wire PE Beams EB3 Third 2-wire/Wireless PE Beam input
6
IN2 2-Wire PE Beam Input EB2 Second 2-wire/Wireless PE Beam input
7
AUX OUT Auxiliary Output to provide trigger to an external device
(N/C & N/O)
EB1 First 2-wire/Wireless PE Beam input
8
FIRE Dedicated input for interfacing opener with a fi re alarm system.
Confi gurable to make door close or open in event of fi re.
(N/C & N/O)
0V Common for PE Beams
9
GPI General Purpose Input, confi gurable to act as a Open/Stop/
Close, Pedestrian, Swipe or Manual Operation trigger. (N/O)
0V Common terminal for inputs 10 to 14
10
OPN Open input that will only open the door trigger from external
device, eg external keyswitch. (N/C & N/O)
FIRE Dedicated input for interfacing opener with a fi re alarm system.
Confi gurable to make door close or open in event of fi re.
(N/C & N/O)
11
STP Stop input that will stop the door upon trigger from external
device, eg emergency stop button. (N/C & N/O)
GPI General Purpose Input, confi gurable to act as a Open/Stop/
Close, Pedestrian, Swipe or Manual Operation trigger. (N/O)
12
CLS Close input that will only close the door upon trigger from
external device, eg loop detector on exit side of doorway. (N/O)
OPN Open input that will only open the door trigger from external
device, eg external keyswitch. (N/C & N/O)
13
SWP Swipe input that will open the door. Multiple triggers will not
stop the open cycle, ie when multiple vehicles access a
carpark in quick succession. (N/O)
STP Stop input that will stop the door upon trigger from external
device, eg emergency stop button. (N/C & N/O)
14
COM Common terminal for inputs 7 to 13 CLS Close input that will only close the door upon trigger from
external device, eg loop detector on exit side of doorway. (N/O)