HP ProLiant Smart Array E200 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Barebones PC/estação de trabalho HP ProLiant Smart Array E200. HP ProLiant Smart Array E200 User guide [en] Manual do Utilizador

/ 118
Índice
Resolução de problemas
HP ProLiant DL360 Generation 5 Server
User Guide
Second Edition (May 2006)
Part Number 406316-002

Ficheiro PDF · ·

Imprimir

Imprimir documento

Partilha

Resumo do Conteúdo

Página 1 - User Guide

HP ProLiant DL360 Generation 5 Server User Guide Second Edition (May 2006) Part Number 406316-002

Página 2

© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties…

Página 3 - Contents

Contents 3 Contents Component identification 7 Front panel components 7 Front panel LEDs and buttons 8 Rear panel components 9 Rear panel LEDs and…

Página 4 - Contents 4

Contents 4 Mirrored memory configuration 39 Installing FBDIMMs 40 Hot-plug SAS and SATA hard drive options 40 Removing hard drive blanks 41 Removing…

Página 5 - Contents 5

Contents 5 Remote support and analysis tools 75 HP Instant Support Enterprise Edition 75 Web-Based Enterprise Service 76 Open Services Event Manager…

Página 6 - Contents 6

Contents 6 Grounding methods to prevent electrostatic discharge 102 Specifications 103 Environmental specifications 103 Server specifications 103…

Página 7

In this section Front panel components 7 Front panel LEDs and buttons 8 Rear panel components 9 Rear panel LEDs and buttons 10 System board components…

Página 8 - Front panel LEDs and buttons

Item Description 8 Hard drive bay 3 9 Hard drive bay 2 10 Hard drive bay 1 *An optional controller is required when the server is configured with six…

Página 9 - Rear panel components

Item Description Status 5 NIC 1 link/activity LED Green = Network link exists. Flashing green = Network link and activity exist. Off = No link to…

Página 10 - Rear panel LEDs and buttons

Item Description 13 iLO 2 NIC connector Rear panel LEDs and buttons Item Description Status 1 iLO 2 NIC activity LED Green = Activity exists. Flashing…

Página 11 - System board components

System board components Item Description 1 System maintenance switch (SW1) 2 NMI switch 3 FBDIMM slots (1-8) 4 Processor socket 2 5 Processor socket 1…

Página 12 - NMI switch

System maintenance switch Position Default Function S1 Off Off = iLO 2 security is enabled. On = iLO 2 security is disabled. S2 Off Off = System…

Página 13

To view the LEDs, access the HP Systems Insight Display (on page 18). Item Description Status 1 Online spare memory LED Green = Protection enabled…

Página 14

HP Systems Insight Display LED and color Internal health LED color Status Processor failure, socket X (amber) Red One or more of the following…

Página 15 - SAS and SATA device numbers

SAS and SATA device numbers Four hard drive configuration Six hard drive configuration

Página 16 - SAS and SATA hard drive LEDs

SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA hard drive LED combinations…

Página 17 - Fan locations

Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Off Steadily amber A critical fault condition has been identified for this…

Página 18

In this section Power up the server 18 Power down the server 18 Access the HP Systems Insight Display 18 Extend the server from the rack 19 Remove the…

Página 19

Extend the display from the chassis. The display can be rotated up to 90 degrees. Extend the server from the rack NOTE: If the optional cable…

Página 20 - Install the access panel

WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release latches and sliding the server into the rack. The…

Página 21

c. Lift the assembly to unseat the PCI riser boards and remove the assembly. Install the PCI riser board assembly CAUTION: To prevent damage to the…

Página 22

Remove the air baffle. Remove the processor air baffle 1. Power down the server (on page 18). 2. Extend or remove the server from the rack ("Extend…

Página 23

Extend or remove the server from the rack ("Extend the server from the rack" on page 19). 3. Remove the access panel (on page 20). 4. To remove fan…

Página 24

IMPORTANT: After installing the fan module, firmly press the top of the module connectors to ensure the connectors are seated properly.

Página 25 - In this section

In this section Optional installation services 25 Rack planning resources 26 Optimum environment 26 Rack warnings 28 Contents of the server shipping…

Página 26 - Optimum environment

Rack planning resources The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more information on…

Página 27 - Power requirements

Temperature requirements To ensure continued safe and reliable equipment operation, install or position the system in a well- ventilated…

Página 28 - Installing hardware options

or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips for the server is not recommended. Rack…

Página 29

If you are installing the server into a telco rack, order the appropriate option kit at the RackSolutions.com website (http://www.racksolutions.com/hp…

Página 30

Item Description 10 Serial connector 11 USB connector 12 USB connector 13 iLO 2 NIC connector 3. Use the strain relief clip from the server hardware…

Mostrar as 118 páginas
Página 31 - Registering the server

Manual installation—Insert the operating system CD into the CD-ROM drive and reboot the server. This process may require you to obtain additional…

Página 32 - Processor option

In this section Introduction 32 Processor option 32 Memory options 37 Hot-plug SAS and SATA hard drive options 40 Multibay device options 43 Redundant…

Página 33

Open the processor retaining latch and the processor socket retaining bracket. 7. Remove the processor socket protective cover. IMPORTANT: Be sure the…

Página 34

If the processor has separated from the installation tool, carefully re-insert the processor in the tool. 9. Align the processor installation tool…

Página 35

Press down firmly until the processor installation tool clicks and separates from the processor, and then remove the processor installation tool. 11.…

Página 36

Remove the heatsink protective cover. 13. Open the heatsink retaining latches.

Página 37 - Memory options

Install the heatsink. 15. Install the processor air baffle. 16. Install the power supply air baffle. 17. Install the access panel (on page 20). 18.…

Página 38 - Advanced ECC memory

FBDIMM pairs in a memory bank must have identical HP part numbers. FBDIMMS must be populated as specified for each AMP memory mode. The memory…

Página 39

current DRAM technology. If the current DRAM technology allows for 2-GB single-rank FBDIMMs, a dual- rank FBDIMM using the same technology would be…

Página 40 - Installing FBDIMMs

Banks A and B must be fully populated. Bank A and bank B must contain FBDIMMs with identical part numbers. If installed, bank C and bank D must also…

Página 41 - Removing hard drive blanks

Hard drives must be SFF types. Drives should be the same capacity to provide the greatest storage space efficiency when drives are grouped together…

Página 42

Removing a hot-plug SAS or SATA hard drive CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are…

Página 43 - Multibay device options

Install the hot-plug hard drive. 4. Determine the status of the hot-plug hard drive by observing the drive LEDs ("SAS and SATA hard drive LED…

Página 44

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.…

Página 45

Remove the power supply blank. 3. Remove the protective cover from the connector pins on the power supply. WARNING: To reduce the risk of electric…

Página 46 - Expansion board options

Install the redundant power supply into the bay until it clicks. 5. Connect the power cord to the power supply. 6. Use the strain relief clip from the…

Página 47

NOTE: If the expansion slot is populated with the standard PCI-X storage controller card, it should not be converted to PCI Express. To install the…

Página 48

Remove the expansion board from the slot, if installed. 6. Remove the full-length PCI Express riser board from the riser board assembly.

Página 49

Install the PCI-X riser board on the riser board assembly. 8. Install a PCI-X expansion board ("Installing an expansion board" on page 46). 9. Install…

Página 50 - P400i Controller

Using a PCI array controller and the HP Smart Array P400i Controller to support six hard drives (on page 62) The Battery-Backed Write Cache Enabler…

Página 51

Disconnect the backplane power cable from the system board. 7. Turn the quarter-turn fasteners and lift the integrated array controller away from the…

Página 52

Turn the quarter-turn fasteners clockwise. Upgrading an HP Smart Array E200i Controller cache module and battery pack Use this procedure to upgrade…

Página 53

Install the optional cache module. 8. Remove fan module 1 and 2 ("Remove and install a fan module" on page 22). 9. Remove the HP Smart Array E200i…

Página 54

Install the HP Smart Array E200i Controller battery pack onto the HP Smart Array E200i Controller battery tray. 11. Install the HP Smart Array E200i…

Página 55

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be…

Página 56

Remove the existing cache module. 8. Install the optional cache module. 9. Install the HP Smart Array P400i Controller ("Installing an integrated HP…

Página 57

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be…

Página 58

Install the HP Smart Array P400i Controller battery pack onto the HP Smart Array P400i Controller battery tray. 15. Install the HP Smart Array P400i…

Página 59

Connect and route the battery pack power cable to the HP Smart Array P400i Controller cache module. 17. Install fan modules 1 and 2 ("Remove and…

Página 60

CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped. 7. Install fan modules 1 and…

Página 61

Disconnect the hard drive backplane power cable from the system board. 8. Turn the quarter-turn fasteners counter-clockwise and lift the integrated…

Página 62

Slide the server into the rack. 15. Power up the server (on page 18). Using a PCI array controller and the HP Smart Array P400i Controller to support…

Página 63 - Cabling

Cabling 63 Cabling In this section Cabling overview 63 Array controller cabling 63 Multibay backplane cabling 66 Cabling overview This section…

Página 64 - Cabling 64

Cabling 64 HP Smart Array E200i Controller cabling CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables…

Página 65 - Battery pack cabling

Cabling 65 PCI Smart Array controller cabling CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do…

Página 66 - Multibay backplane cabling

Cabling 66 HP Smart Array P400i Controller battery pack cabling Multibay backplane cabling

Página 67

In this section Configuration tools 67 Management tools 71 Diagnostic tools 74 Remote support and analysis tools 75 Keeping the system current 76…

Página 68 - HP ROM-Based Setup Utility

For more information, and to download the SmartStart Scripting Toolkit, refer to the HP website (http://www.hp.com/servers/sstoolkit ). Configuration…

Página 69 - Configuring mirrored memory

Drives installed Drives used RAID level 1 1 RAID 0 2 2 RAID 1 3, 4, 5, or 6 RAID 5 More than 6 0 None To change any ORCA default settings and override…

Página 70 - Array Configuration Utility

Access RBSU by pressing the F9 key during power-up when the prompt is displayed in the upper right corner of the screen. 3. Select System Options. 4.…

Página 71 - Management tools

The RDP software is the preferred method for rapid, high-volume server deployments. The RDP software integrates two powerful products: Altiris…

Página 72 - Erase Utility

For more information about the ROMPaq utility, refer to the HP website (http://www.hp.com/servers/manage ). System Online ROM flash component utility…

Página 73 - Redundant ROM support

Management Agents provide the information to enable fault, performance, and configuration management. The agents allow easy manageability of the…

Página 74 - Diagnostic tools

Set positions 1, 5, and 6 of the system maintenance switch to On. 4. Install the access panel (on page 20). 5. Power up the server (on page 18). 6.…

Página 75 - Integrated Management Log

If a significant change occurs between data-gathering intervals, the Survey Utility marks the previous information and overwrites the Survey text…

Página 76 - Keeping the system current

identify and prevent potential critical problems. Through remote diagnostic scripts and vital system configuration information collected about your…

Página 77

Resource Paqs are operating system-specific packages of tools, utilities, and information for HP servers running certain Microsoft® or Novell…

Página 78 - Care Pack

Care Pack HP Care Pack Services offer upgraded service levels to extend and expand standard product warranty with easy-to-buy, easy-to-use support…

Página 79

In this section Troubleshooting resources 79 Pre-diagnostic steps 79 Loose connections 82 Service notifications 82 Troubleshooting flowcharts 83 POST…

Página 80 - Warnings and cautions

Important safety information Before servicing this product, read the Important Safety Information document provided with the server. Symbols on…

Página 81 - Symptom information

WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: The leveling feet are extended to the floor. The full weight…

Página 82 - Service notifications

Prepare the server for diagnosis 1. Be sure the server is in the proper operating environment with adequate power, air conditioning, and humidity…

Página 83 - Troubleshooting flowcharts

Troubleshooting flowcharts To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section, "Start…

Página 84 - General diagnosis flowchart

General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if…

Página 85

Item Refer to 4 The most recent version of a particular server or option firmware is available on the following websites: HP Support website…

Página 86 - Symptoms:

Server power-on problems flowchart Symptoms: The server does not power on. The system power LED is off or amber. The external health LED is red or…

Página 87

The internal health LED is red or amber. NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.…

Página 88

Troubleshooting 88

Página 89 - POST problems flowchart

POST problems flowchart Symptoms: Server does not complete POST NOTE: The server has completed POST when the system attempts to access the boot…

Página 90 - OS boot problems flowchart

OS boot problems flowchart Symptoms: Server does not boot a previously installed operating system Server does not boot SmartStart Possible causes…

Página 91

Item Refer to 1 HP ROM-Based Setup Utility User Guide (http://www.hp.com/servers/smartstart ) 2 "POST problems flowchart (on page 89)" 3 "Hard drive…

Página 92

Server fault indications flowchart Symptoms: Server boots, but a fault event is reported by Insight Management Agents (on page 73) Server boots, but…

Página 93 - Redundancy failure

Possible causes: Improperly seated or faulty internal or external component Unsupported component installed Redundancy failure System overtemperature…

Página 94

POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers…

Página 95 - System battery

System battery 95 System battery If the server no longer automatically displays the correct date and time, you may need to replace the battery that…

Página 96 - FCC rating label

In this section Regulatory compliance identification numbers 96 Federal Communications Commission notice 96 Declaration of conformity for products…

Página 97 - FCC logo, United States only

Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC…

Página 98 - Modifications

Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by…

Página 99 - BSMI notice

Disposal of waste equipment by users in private households in the European Union This symbol on the product or on its packaging indicates that this…

Página 100 - Battery replacement notice

Korean notice Class A equipment Class B equipment Laser compliance This product may be provided with an optical storage device (that is, CD or DVD…

Página 101

Do not attempt to recharge the battery. Do not expose the battery to temperatures higher than 60°C (140°F). Do not disassemble, crush, puncture, short…

Página 102 - Electrostatic discharge

Electrostatic discharge 102 Electrostatic discharge In this section Preventing electrostatic discharge 102 Grounding methods to prevent electrostatic…

Página 103 - Specifications

Specifications 103 Specifications In this section Environmental specifications 103 Server specifications 103 Environmental specifications…

Página 104

Specifications 104 Specification Value Rated input power 852 W BTUs per hour 2910 (at 120 VAC); 2870 (at 240 VAC) Power supply output Rated…

Página 105

In this section Related documents 105 HP contact information 105 Customer Self Repair 105 Related documents For related documentation, refer to the…

Página 106

Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be…

Página 107 - Customer Self Repair

assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due…

Página 108

stellen. Im Falle von Customer Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den Kurier-/Frachtdienst.…

Página 109 - Reparo feito pelo cliente

Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service…

Página 110

Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa…

Página 111

Technical support 111

Página 112

Technical support 112

Página 113 - Acronyms and abbreviations

Acronyms and abbreviations 113 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR…

Página 114

Acronyms and abbreviations 114 NEMA National Electrical Manufacturers Association NFPA National Fire Protection Association NIC network interface…

Página 115

Acronyms and abbreviations 115 RBSU ROM-Based Setup Utility SAS serial attached SCSI SATA serial ATA SDRAM synchronous dynamic RAM SFF small…

Página 116 - Index 116

Index 116 A AC power supply 9, 11 access panel 20 ACU (Array Configuration Utility) 70 additional information 105 ADU (Array Diagnostic Utility) 75…

Página 117 - Index 117

Index 117 G general diagnosis flowchart 84 grounding methods 102 grounding requirements 27 H hard drive bezel blanks 41 hard drive LEDs 16 hard drives…

Página 118 - Index 118

Index 118 power supply LEDs 12, 13 powering down 18 powering up 18, 68 PPM failure LEDs 12, 13, 15 preparation procedures 82 problem diagnosis 79…

Mais documentos para Barebones PC/estação de trabalho HP ProLiant Smart Array E200

Perguntas sobre HP ProLiant Smart Array E200

Ainda não há perguntas sobre este manual. Faça a primeira.

Fazer uma pergunta

Respondemos a partir do manual e indicamos a página. A pergunta é publicada no site depois de verificada.

Todas as perguntas e respostas ›

Manuais e produtos relacionados com Barebones PC/estação de trabalho HP ProLiant Smart Array E200