HP ProLiant ML370 G5 Model (tower)
Front View:
Rear View:
1.
System Insight Display (SID)
1.
Keyboard connector
2.
Media Bay Spacer (Tower)/Video Connector (Rack)
2.
Mouse connector
3.
DVD-ROM Drive
3.
USB connectors
4.
Removable Media Bays
4.
Integrated Lights-Out 2 (iLO 2) management connector
5.
Front Bezel (Tower Model Only)
5.
Video connector
6.
Hard Drive Bays 1-8 (Serial-attached SCSI (SAS) drives
supported - SFF)
6.
Serial connector
7.
NIC 2 connector
7.
Hard Drive Bays 9-16 - Optional Drive Cage (Serial-
attached SCSI (SAS) drives supported - SFF)
8.
PCI expansion slots
9.
Hot-plug power supply (primary bay)
8.
Integrated RAID Controller Slot
10.
Hot-plug power supply blank (redundant bay)
9.
(2) PCI-X 64 Bit/133MHz Slot
11.
NIC 1 connector
10.
(6) PCI-Express x4 Slot
12.
T-15 Torx screwdriver
11.
(8) PC2-5300 Fully Buffered DIMM Slots per memory card -
Standard
12.
(8) PC2-5300 Fully Buffered DIMM Slots per memory card -
Optional
13.
Dual-Core Intel Xeon processor - Optional
14.
Dual-Core Intel Xeon processor - Standard (2 processors
standard on all Performance Models)
15.
(3) Hot Plug Redundant Fans - Standard
16.
(3) Hot Plug Redundant Fans - Optional
QuickSpecs
HP ProLiant ML370 Generation 5
Overview
DA - 12478 Worldwide QuickSpecs — Version 45 — 7.13.2009
Page 1
Vista de página 0
1 2 3 4 5 6 ... 40 41

Resumo do Conteúdo

Página 1 - QuickSpecs

HP ProLiant ML370 G5 Model (tower)Front View:Rear View:1.System Insight Display (SID)1.Keyboard connector2.Media Bay Spacer (Tower)/Video Connector (R

Página 2

Industry StandardComplianceACPI 1.0b CompliantPCI 2.2 CompliantWOL SupportMicrosoft® Logo certificationsPXE SupportSecurityPower-on passwordKeyboard p

Página 3

Operating Systems andVirtualization SoftwareSupport for ProLiantServersMicrosoft Windows ServerMicrosoft Windows Server Hyper VRed Hat Enterprise Linu

Página 4

Factory Express Portfoliofor Servers and StorageHP Factory Express offers configuration, customization, integration and deployment services for HP ser

Página 5

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information – FactoryIntegrat

Página 6

HP ML370 G5 EntryModelsTower Models:Quad-Core:ML370T05 E5410458347-xx1Dual-Core:Rack Models:Quad-Core:ML370R05 E5410458348-xx1Processor(s)One of the f

Página 7

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Página 8

Step 2: Choose Required Options (only one of the following from each list)ProcessorsNOTE: If High Performance Model features are desired, 2nd processo

Página 9

Step 4: Choose Additional Options for Factory IntegrationNOTE: For additional options, please refer to the "Core Options" and "Addition

Página 10

NOTE: Some options may not be factory configurable. Please contact your local sales representative for additionalinformation. HP ProLiant ML370Unique

Página 11

Memory1 GB FBD PC2-5300 2 x 512 MB Single Rank Kit397409-B212 GB FBD PC2-5300 2 x 1 GB Dual Rank Kit397411-B212 GB FBD PC2-5300 2 x 1 GB Low Power Sin

Página 12

HP ProLiant ML370 G5 Model (Rack)Front View:Rear View:1.System Insight Display (SID)1.Keyboard connector2.Video Connector2.Mouse connector3.DVD/CD-ROM

Página 13

HP 160GB 3G SATA 7.2K 2.5in MDL HDD530888-B21SATA Hot Plug SFF Entry (ETY) Drives HP 250GB 3G SATA 5.4K SFF ETY HDD460355-B21HP 120GB 1.5G SATA 5.4K S

Página 14

HP Insight Control (ICE)suitesHP Insight Control suite (ICE)HP Insight Control suite, No Media 1-Server License including 1 year of 24x7Technical Supp

Página 15

HP Smart Array P600/256 BBWC ControllerNOTE: Supports external drive attach.337972-B21Smart Array P800 Controller HP Smart Array P800/512 BBWC Control

Página 16

SCSI HBA HP SC11Xe Host Bus AdapterNOTE: Recommended HBA for SCSI tape drive connect.412911-B21NOTE: Please see the QuickSpecs for Technical Specifica

Página 17

NOTE: Please reference the MSL Tape Library QuickSpecs at:http://www.hp.com/go/automation for additional information needed to create acomplete soluti

Página 18

HP StorageWorksModular Smart ArrayMSA SAN Storage Arrays HP StorageWorks 50 Modular Smart Array364430-B21NOTE: Please see the QuickSpecs for additiona

Página 19

HP R3000 VA UPS, 2U, High voltage L6-20, JPNAF424AHP R3000 VA UPS, 2U, Low voltage L5-30, JPNAF425ANOTE: Please see the QuickSpecs for Technical Speci

Página 20

3.6kVA Model - mPDU, 16A, High (WW)252663-B242.8 kVA Model - mPDU, 24A, Low (NA/JPN)252663-D714.9kVA Model - mPDU, 24A, High (NA/JPN)252663-D727.3kVA

Página 21

NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_d

Página 22

2x16 Server Console Switch with Virtual MediaAF600APS/2 Virtual Media Interface Adapter, 1 packNOTE: Requires PS/2 and one USB port on server.AF604ASe

Página 23

Advanced ECC capabilities including Online Spare and Mirrored Memory (8 FB DIMMs per memory card; up to 2supported)NOTE: Memory DIMMs in systems with

Página 24

Service and SupportOfferings(HP Care Pack Services)Hardware Services On-site Service 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electr

Página 25

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) r

Página 26

ADVD-ROM Drive (Performance Models)/48x IDE CD-ROM Drive (Base and Entry Models)B, CDVD-ROM Drive (Performance Models)/48x IDE CD-ROM Drive (Base and

Página 27

QuantitySupportedPositionSupportedController500GB 6G SAS 7.2K DPUp to 161-16HP Smart Array E200/64MB ControllerHP Smart Array E200/128 BBWC Controlle

Página 28

External Storage QuantitySupportedPositionSupportedHost Controller or Adapter50 Modular Smart Array1 per externalVHDCI SCSIconnectorExternalHP Smart A

Página 29

LTO-3 Ultrium 920LTO-4 Ultrium 1760LTO-4 Ultrium 1840DAT 40DAT 72DAT 1601U Rack-Mount Kit3U Rack-Mount Kit SAS Tape Drives, InternalDAT 160 SASLTO-2

Página 30

HP StorageWorks RDXRemovable Disk BackupSystem, InternalRDX160RDX320RDX500B,CUSB 2.0 PortN/A HP StorageWorks RDXRemovable Disk BackupSystem, Ex

Página 31

Part Number380622-001Spare Kit403781-001Operational Input VoltageRange (V rms)90 to 264Frequency Range(Nominal) (Hz)47 to 63 (50/60) Nominal Input Vo

Página 32

System UnitTower Dimensions(H x W x D) (with bezel)18.38 x 8.63 x 28.5 in (46.67 x 21.92 x 72.39 cm)Rack Dimensions(H x W x D) (with bezel)8.63 x 17.5

Página 33

10°C/hr (18°F/hr). The upper limit may belimited by the type and number of optionsinstalled.System performance may be reduced if operatingwith a fan f

Página 34

Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date ofpurchase. Support for software

Página 35

Smart Array P400ControllerDisk Drive and EnclosureInterface3G SAS (Serial Attached SCSI)1.5G SATA (Serial Advanced Technology Attachment)SAS Connector

Página 36

Two embedded NC373iMultifunction GigabitServer AdaptersNetwork Interface10Base-T/100Base-TX/1000Base-TXCompatibilityIEEE 802.3 10Base-TIEEE 802.3ab 10

Página 37

NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities andspecifications, please vis

Página 38

Memory ProtectionAdvanced ECC, Online Spare and MirroringNOTE: Mirroring requires optional 2nd memory card.MemoryOne of the followingdepending on Mode

Página 39

8PCIex4 x825Full length, fullheight slot9PCIex4 x822Full length, fullheight slotOptional x8 ifPCIEexpander isinstalled in slot8* Default bus assignmen

Página 40

InterfacesSerial1 (2nd serial and parallel port available via option Kit)Pointing Device (Mouse)1VGA1 (+1 front VGA on rack models)Keyboard1Network RJ

Página 41

Control suites, and the Insight Dynamics-VSE suite helping customers unlockthe value of the ProLiant platform and deliver the highest possible quality