HP ML370 - ProLiant - G3 Especificações

Consulte online ou descarregue Especificações para Servidores HP ML370 - ProLiant - G3. HP ML370 - ProLiant - G3 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 113
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
HP ProLiant ML370 Generation 3 Server
Maintenance and Service Guide
January 2004 (Sixth Edition)
Part Number 281778-006
Vista de página 0
1 2 3 4 5 6 ... 112 113

Resumo do Conteúdo

Página 1 - Part Number 281778-006

HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide January 2004 (Sixth Edition) Part Number 281778-006

Página 2

1 Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and a spare parts list for ProLiant ML370 Generation 3 servers. Figu

Página 3 - Contents

Specifications Tower Server Table 5-1: Tower Server Specifications Feature Metric Units English Units Dimensions Height Without feet 44.45

Página 4

Specifications Rack Server Table 5-2: Rack Server Specifications Feature Metric Units English Units Dimensions Height 22.07 cm 8.69 in Depth

Página 5

Specifications Memory Modules Table 5-3: Memory Module Specifications Feature Description DIMM sizes 256 MB, 512 MB, 1 GB, or 2 GB Maximum memory

Página 6

Specifications 1.44-MB Diskette Drive Table 5-4: 1.44-MB Diskette Drive Specifications Feature Description Size 8.89 cm (3.5 in) LEDs (front panel)

Página 7 - About This Guide

Specifications CD-ROM Drive Table 5-5: CD-ROM Drive Specifications Feature Description Applicable disk CD-ROM (modes 1 and 2); mixed mode (audio an

Página 8

Specifications Table 5-5: CD-ROM Drive Specifications continued Feature Description Operating conditions Temperature 5° to 45°C (41° to 113°F) Hum

Página 9 - Telephone Numbers

Specifications 5-8 HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide Wide Ultra3 Hot-Plug SCSI Hard Drive Table 5-6: Wide Ultra3

Página 10 - Illustrated Parts Catalog

Index bezel, rack part numbers 1-4 3 removing 2-15 3-device SCSI cable, part number 1-6 replacing 2-15 BIOS settings, reconfiguring 2-58 A

Página 11 - Mechanical Components

Index CDs diskette drive cable Management 3-3 disconnecting 2-42 SmartStart 3-3 part number 1-6 center wall replacing 2-43 part numbers 1-

Página 12 - System Components

Index G I grounding viii icons, symbols on equipment 2-2 grounding guidelines 2-1 IML See Integrated Management Log (IML) grounding plug

Página 13

Illustrated Parts Catalog Mechanical Components Figure 1-1: Mechanical components 1-2 HP ProLiant ML370 Generation 3 Server Maintenance and Service

Página 14

Index K media blanks part numbers 1-4 keyboard, part numbers 1-6 removing 2-21 kits replacing 2-21 country See country kit media latch hardw

Página 15

Index Power On/Standby button rack mounting kits LED 2-7 Telco option See Telco rack mounting option kit rack server 2-7 tower server 2-8 thir

Página 16 - Safety Considerations

Index power supplies, hot-plug 2-18 requirements power supply backplane 2-54 hot-plug procedures 2-11 power supply blank 2-17 local occupation

Página 17 - Rack Warnings and Cautions

Index system LEDs 4-1 removing front bezel 2-13 system power LED 2-7, 2-8 specifications 5-2 T U technician notes vii unit identification

Página 18 - Server Warnings and Cautions

Illustrated Parts Catalog System Components Figure 1-2: System components HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide 1-3

Página 19 - Preparation Procedures

Illustrated Parts Catalog Mechanical and System Spare Parts List Table 1-1: Mechanical and System Spare Parts List Item Description Assembly Number

Página 20

Illustrated Parts Catalog Table 1-1: Mechanical and System Spare Parts List continued Item Description Assembly Number Spare Part Number Boards 1

Página 21

Illustrated Parts Catalog 1-6 HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide Table 1-1: Mechanical and System Spare Parts List

Página 22 - Powering Down the Server

2 Removal and Replacement Procedures This chapter provides subassembly/module-level removal and replacement procedures for the server. After completin

Página 23

Removal and Replacement Procedures Symbols on Equipment up to 34 kg up to 75 lb Any product or assembly marked with these symbols indicates that the

Página 24

Removal and Replacement Procedures WARNING: To reduce the risk of personal injury or damage to the equipment, use two or more people to safely unlo

Página 25

Removal and Replacement Procedures Preparation Procedures To access some components and perform certain service procedures, you must do one or more of

Página 26 - Hot-Plug Procedures

© 2002, 2004 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the U.S. and othe

Página 27

Removal and Replacement Procedures Extending the Server from the Rack To extend the server from the rack: 1. Loosen the thumbscrews that secure the f

Página 28 - Front Bezel

Removal and Replacement Procedures After performing the installation or maintenance procedure: 1. Press the tabs on the ends of both sliding server r

Página 29 - Access Panel

Removal and Replacement Procedures Powering Down the Server System power for the server does not completely shut off with the front panel Power On/Sta

Página 30 - Rack Bezel

Removal and Replacement Procedures 6. Disconnect all external peripheral devices from the server. 7. Place the server on a sturdy, level surface. To

Página 31 - Rack Rails

Removal and Replacement Procedures Removing the Server from the Rack You need to remove the server from the rack when performing non-hot-plug removal

Página 32 - Power Supply Blank

Removal and Replacement Procedures 3. Disconnect all external peripheral devices from the server. 4. Remove the cable management arm from the server

Página 33 - Hot-Plug Power Supply

Removal and Replacement Procedures Hot-Plug Procedures You can perform hot-plug procedures without powering down the server. Before performing hot-plu

Página 34 - Hard Drive Blank

Removal and Replacement Procedures Feet NOTE: This procedure applies to tower servers only. To remove the feet: 1. Place the server on its side. 2

Página 35 - Hot-Plug SCSI Hard Drive

Removal and Replacement Procedures Front Bezel NOTE: This procedure applies to tower servers only. To remove the front bezel: 1. Unlock and open t

Página 36 - Removable Media Blanks

Removal and Replacement Procedures Access Panel WARNING: To reduce the risk of personal injury from hot surfaces, allow internal system components

Página 37 - System Fans

Contents About This Guide Audience Assumptions...

Página 38 - Bezel” in this chapter

Removal and Replacement Procedures Rack Bezel NOTE: This procedure applies to rack servers only. To remove the rack bezel: 1. Remove the access pa

Página 39 - Non-Hot-Plug Procedures

Removal and Replacement Procedures Rack Rails NOTE: This procedure applies to rack servers only. To remove the rack rails: 1. Use the Torx T-15 to

Página 40 - Redundant Fan Cage

Removal and Replacement Procedures Power Supply Blank To remove a power supply blank: 1. Remove the two screws with the Torx T-15 tool (1). NOTE:

Página 41

Removal and Replacement Procedures Hot-Plug Power Supply WARNING: To reduce the risk of electric shock, do not disassemble the power supply or atte

Página 42 - Hard Drive Cage

Removal and Replacement Procedures Hard Drive Blank IMPORTANT: A device or blank must occupy each bay during operation. To remove a hard drive blank

Página 43

Removal and Replacement Procedures Hot-Plug SCSI Hard Drive To remove a hot-plug SCSI hard drive: 1. Unlock and open the front bezel door (tower serv

Página 44 - PCI-X Expansion Board Slots

Removal and Replacement Procedures Removable Media Blanks NOTE: HP recommends that you remove or extend the CD-ROM drive to ease removable media bla

Página 45 - PCI-X Expansion Slot Cover

Removal and Replacement Procedures System Fans The server supports redundant hot-plug fans to provide proper airflow to the system. In the standard co

Página 46 - PCI-X Expansion Boards

Removal and Replacement Procedures For additional information, refer to the HP ProLiant ML370 Generation 3 Server Setup and Installation Guide. All f

Página 47

Removal and Replacement Procedures Non-Hot-Plug Procedures CAUTION: To avoid the risk of damage to the system or non-hot-plug expansion boards, dis

Página 48 - PCI-X Slot Release Lever

Contents PCI-X Expansion Board Slots...2-29 PC

Página 49 - PCI-X Guide Clips

Removal and Replacement Procedures Redundant Fan Cage To remove the optional redundant fan cage: 1. Power down and remove power from the server. Refe

Página 50 - Processor Air Baffle

Removal and Replacement Procedures Figure 2-23: Removing the redundant fan cage To replace the redundant fan cage, reverse steps 4 through 7. 2-26

Página 51 - Center Wall

Removal and Replacement Procedures Hard Drive Cage To remove the hard drive cage: 1. Power down and remove power from the server. Refer to “Powering

Página 52

Removal and Replacement Procedures Figure 2-25: Removing the hard drive cage To replace the hard drive cage, reverse steps 5 through 8. CAUTION:

Página 53 - IDE CD-ROM Drive

Removal and Replacement Procedures PCI-X Expansion Board Slots Figure 2-26: PCI-X expansion board slots Table 2-2: PCI-X Expansion Board Slots Ite

Página 54

Removal and Replacement Procedures PCI-X Expansion Slot Cover To remove a PCI-X expansion slot cover: 1. Power down the server. Refer to “Powering Do

Página 55 - Power Button/LED Assembly

Removal and Replacement Procedures PCI-X Expansion Boards CAUTION: To avoid the risk of damage to your system or expansion boards, disconnect all A

Página 56

Removal and Replacement Procedures 6. Press the PCI-X slot release lever (1) and swing the slot release lever upward (2). 7. Lift the expansion boar

Página 57 - Diskette Drive

Removal and Replacement Procedures PCI-X Slot Release Lever To remove a PCI-X slot release lever: 1. Power down and remove power from the server. Ref

Página 58

Removal and Replacement Procedures PCI-X Guide Clips To remove a PCI-X guide clip: 1. Power down and remove power from the server. Refer to “Powering

Página 59 - Processor Assembly

Contents Index HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide v

Página 60

Removal and Replacement Procedures Processor Air Baffle To remove the processor air baffle: 1. Power down and remove power from the server. Refer to

Página 61

Removal and Replacement Procedures Center Wall To remove the center wall: 1. Power down and remove power from the server. Refer to “Powering Down the

Página 62

Removal and Replacement Procedures 7. Disconnect the fan cable from the system board. Figure 2-34: Disconnecting the fan cable 8. Lift the center

Página 63

Removal and Replacement Procedures IDE CD-ROM Drive To remove the IDE CD-ROM drive: 1. Power down and remove power from the server. Refer to “Powerin

Página 64 - Processor Power Module

Removal and Replacement Procedures 5. Disconnect the IDE cable from the CD-ROM drive (1). 6. Disconnect the power cable from the CD-ROM drive (2).

Página 65 - To replace a PPM:

Removal and Replacement Procedures Power Button/LED Assembly To remove the power button/LED assembly: 1. Power down and remove power from the server.

Página 66 - Figure 2-48: DIMM slots

Removal and Replacement Procedures 9. Squeeze the two tabs from the inside (1) and slide the power button/LED assembly through the front of the serve

Página 67

Removal and Replacement Procedures Diskette Drive To remove the diskette drive: 1. Power down and remove power from the server. Refer to “Powering Do

Página 68

Removal and Replacement Procedures 10. Loosen the thumbscrew that secures the retaining bracket to the diskette chassis (1). 11. Pull the diskette ret

Página 69 - Power Supply Backplane

Removal and Replacement Procedures Processor Assembly CAUTION: Be sure that you have the current version of the system ROM. Failure to flash you

Página 71 - System Board

Removal and Replacement Procedures 7. Lift the processor retaining bracket (1). 8. Release the processor locking lever (2). Figure 2-42: Lifting t

Página 72 - Processor Cage Assembly

Removal and Replacement Procedures To replace the processor assembly: 1. Open the processor retaining bracket 2. Install the processor/heatsink asse

Página 73 - Battery

Removal and Replacement Procedures Figure 2-44: Installing the processor/heatsink assembly and securing the processor locking lever 3. Lower the pr

Página 74

Removal and Replacement Procedures Figure 2-46: Securing the processor retaining bracket lever. CAUTION: Before closing the processor retaining b

Página 75

Removal and Replacement Procedures Processor Power Module To remove a Power Processor Module (PPM): 1. Power down and remove power from the server. R

Página 76 - Diagnostic Tools

Removal and Replacement Procedures To replace a PPM: 1. Position the PPM above the slot. The PPM is keyed to fit only one way in the slot. 2. Press

Página 77 - Diagnostic Tools Overview

Removal and Replacement Procedures Memory Use Figure 2-48 and Table 2-3 to identify DIMM slots on the server system board. The slots are numbered sequ

Página 78

Removal and Replacement Procedures DIMM Installation Guidelines The following guidelines must be followed when installing or replacing memory: • • • A

Página 79

Removal and Replacement Procedures CAUTION: Use only HP or Compaq branded DIMMs. DIMMs from other sources may adversely affect data integrity. IMP

Página 80 - LED Indicators and Switches

Removal and Replacement Procedures Power Supply Backplane To remove the power supply backplane from the chassis: 1. Power down and remove power from

Página 81 - Front Panel LEDs

About This Guide This maintenance and service guide is a troubleshooting guide that can be used for reference when servicing the HP ProLiant ML370 Ge

Página 82

Removal and Replacement Procedures 9. Loosen the two thumbscrews securing the backplane to the chassis (1). 10. Grasp the backplane, pulling toward t

Página 83

Removal and Replacement Procedures System Board IMPORTANT: You must re-enter the server serial number through RBSU if you replace the system board.

Página 84 - RJ-45 Connector LEDs

Removal and Replacement Procedures To replace the system board and all components connected to it, reverse steps 4 through 11. NOTE: Be sure that yo

Página 85

Removal and Replacement Procedures 13. Remove the processor cage and the processor plate. To replace the processor cage, reverse steps 9 through 12.

Página 86 - Hot-Plug Power Supply LEDs

Removal and Replacement Procedures 3. Remove the access panel. Refer to “Access Panel” in this chapter. 4. Locate the battery and remove it from the

Página 87 - Hot-Plug Fan LEDs

Removal and Replacement Procedures 2-60 HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide Re-entering the Server Serial Number Afte

Página 88 - System Board LEDs

3 Diagnostic Tools This chapter is an overview of software and firmware diagnostic tools that are available for configuring, monitoring, and managing

Página 89

Diagnostic Tools Diagnostic Tools Overview Use the following tools to diagnose problems, test hardware, and monitor and manage server operations. Tab

Página 90 - External Health LED

Diagnostic Tools Table 3-1: Diagnostic Tools continued Tool Description How to run the tool SmartStart Software SmartStart software is the intell

Página 91

Diagnostic Tools 3-4 HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide Table 3-1: Diagnostic Tools continued Tool Description Ho

Página 92

CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server. CAUTION:

Página 93 - System Board Switches

4 LED Indicators and Switches This chapter provides information about locating and using system LEDs and switches in the server. For additional inform

Página 94

LED Indicators and Switches Front Panel LEDs The set of five LEDs on the front of the server indicates system health. Figure 4-1 and Table 4-1 identif

Página 95 - System Identification Switch

LED Indicators and Switches Hot-Plug SCSI Hard Drive LEDs Each hot-plug SCSI hard drive has three LEDs located on the front of the drive. They provide

Página 96 - System Maintenance Switch

LED Indicators and Switches Table 4-3: Hot-Plug SCSI Hard Drive LED Combinations Activity LED Online LED Fault LED Status On Off Off Do not remov

Página 97

LED Indicators and Switches RJ-45 Connector LEDs The RJ-45 connector on the server rear panel has two LEDs. Figure 4-3 and Table 4-4 identify the LED

Página 98

LED Indicators and Switches Rear Unit Identification LED Switch The server includes unit identification (UID) LEDs with switches on both the front and

Página 99 - Specifications

LED Indicators and Switches Hot-Plug Power Supply LEDs Determine the hot-plug power supply status by noting the color of the power supply LED located

Página 100 - Tower Server

LED Indicators and Switches Hot-Plug Fan LEDs Each hot-plug fan contains a dual-color LED. Figure 4-6: Hot-plug fan LED The hot-plug fan LED indicat

Página 101 - Rack Server

LED Indicators and Switches System Board LEDs The following LEDs are located on the system board: • • • • • • Processor status PPM status Memory statu

Página 102 - Memory Modules

LED Indicators and Switches Table 4-6: System Board LEDs continued Item Description Status 7 PPM 2 Amber = Processor or PPM failed Off = Normal 8

Página 103 - 1.44-MB Diskette Drive

Where to Go for Additional Help In addition to this guide, the following information sources are available: • User documentation • Service Quick Re

Página 104 - CD-ROM Drive

LED Indicators and Switches External Health LED Table 4-7: External Health LED System LED and Color External Health LED Color Status Red Primary

Página 105

LED Indicators and Switches System LEDs and Internal Health LED Status Combinations When the internal health LED on the front panel illuminates either

Página 106

LED Indicators and Switches Table 4-8: System LEDs and Internal Health LED Status Combinations continued System LED and Color Internal Health LED Co

Página 107

LED Indicators and Switches System Board Switches Some server operations, including adding or removing a component, changing a security feature, or re

Página 108

LED Indicators and Switches Non-Maskable Interrupt Switch Crash dump analysis is an essential part of eliminating reliability problems such as hangs o

Página 109

LED Indicators and Switches System Identification Switch The system identification switch (SW2) is a three-position switch that identifies the operati

Página 110

LED Indicators and Switches System Maintenance Switch The system maintenance switch (SW1) is a six-position switch that is used for system configurati

Página 111

LED Indicators and Switches System Configuration Settings It may be necessary at some time to clear and reset system configuration settings. When the

Página 112

LED Indicators and Switches HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide 4-19 ROMPaq Disaster Recovery Mode A corrupted system

Página 113

5 Specifications This chapter provides operating and performance specifications for the server and optional hardware, including the following: • • • •

Comentários a estes Manuais

Sem comentários