HP ProLiant DL370 Generation 6 Especificações

Consulte online ou descarregue Especificações para Servidores HP ProLiant DL370 Generation 6. HP ProLiant DL370 Generation 6 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 84
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
HP ProLiant ML370 Generation 4 Server
Maintenance and Service Guide
December 2005 (Seventh Edition)
Part Number 346895-007
Vista de página 0
1 2 3 4 5 6 ... 83 84

Resumo do Conteúdo

Página 1 - Part Number 346895-007

HP ProLiant ML370 Generation 4 Server Maintenance and Service Guide December 2005 (Seventh Edition) Part Number 346895-007

Página 2 - Audience assumptions

Illustrated parts catalog 10 Item Description Assembly Part Number Spare Part Number Customer Replaceable 21 Plastics kit — 365962-001 Yes a) Foot

Página 3 - Contents

Illustrated parts catalog 11 Item Description Assembly Part Number Spare Part Number Customer Replaceable c) Point-to-point SCSI cable* 166298-037

Página 4 - Contents 4

Illustrated parts catalog 12 Item Description Assembly Part Number Spare Part Number Customer Replaceable f) 36.4-GB, 15,000 rpm 286776-B22 289241

Página 5 - Contents 5

Removal and replacement procedures 13 Removal and replacement procedures In this section Required tools...

Página 6 - Illustrated parts catalog

Removal and replacement procedures 14 • T-15 Torx screwdriver (included with the server) • Diagnostics Utility (included on the SmartStart CD-ROM)

Página 7 - Mechanical components

Removal and replacement procedures 15 25-41 kg 55-90 lbs This symbol indicates that the component exceeds the recommended weight for one individu

Página 8 - System components

Removal and replacement procedures 16 If you must remove a server from a rack or a non-hot-plug component from a server, power down the server. • R

Página 9

Removal and replacement procedures 17 a. Press the server rail-release latches and slide the server fully into rack. b. Secure the server by tight

Página 10

Removal and replacement procedures 18 2. Remove the feet. To replace the component, slide it back onto the locking slot. Be sure that the foot snap

Página 11

Removal and replacement procedures 19 Front bezel Tower servers have a removable front bezel that must be unlocked and opened before accessing the h

Página 12

© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Página 13 - Required tools

Removal and replacement procedures 20 2. Lift up the front bezel and remove it from the chassis. To replace the component, reverse the removal proc

Página 14 - Safety considerations

Removal and replacement procedures 21 3. Loosen the two thumbscrews that secure the rack bezel to the chassis. 4. Remove the rack bezel. To repla

Página 15 - Preparation procedures

Removal and replacement procedures 22 4. Remove the tower hood cover. To replace the component, reverse the removal procedure. Rack rails NOTE:

Página 16 - Powering down the server

Removal and replacement procedures 23 Power supply blank WARNING: To reduce the risk of electric shock, do not disassemble the power supply or at

Página 17

Removal and replacement procedures 24 3. Remove the power supply. CAUTION: To prevent improper cooling and thermal damage, do not operate the se

Página 18 - Remove the feet

Removal and replacement procedures 25 Hard drives (SCSI) CAUTION: To prevent improper cooling and thermal damage, do not operate the server unles

Página 19 - Front bezel

Removal and replacement procedures 26 10. Disconnect the power cable from the SCSI hard drive backplane. 11. Remove the four (4) screws that secur

Página 20 - Access panel

Removal and replacement procedures 27 2. Remove the blank. To replace the component, reverse the removal procedure. Hard drives (SAS) CAUTION:

Página 21 - Tower hood cover

Removal and replacement procedures 28 Hard drive cage (SAS) 1. Power down the server ("Powering down the server" on page 16). 2. Unlock

Página 22 - Rack rails

Removal and replacement procedures 29 8. Unscrew and remove the four screws that secure the drive cage to the chassis and remove the SAS cage. To r

Página 23 - Hot-plug power supply

Contents 3 Contents Illustrated parts catalog ...

Página 24 - Hard drive blank (SCSI)

Removal and replacement procedures 30 4. Remove the fan. To replace the component, reverse the removal procedure. Redundant hot-plug fan cage For

Página 25 - Hard drive cage (SCSI)

Removal and replacement procedures 31 IMPORTANT: Do not discard the fan cage retaining bracket. The bracket is required for proper fan operation.

Página 26 - Hard drive blank (SAS)

Removal and replacement procedures 32 8. Reinstall the redundant fan cage retaining bracket. To replace the component, reverse the removal procedur

Página 27 - Hard drives (SAS)

Removal and replacement procedures 33 Slot release lever To remove the component: 1. Power down the server ("Powering down the server" on

Página 28 - Hard drive cage (SAS)

Removal and replacement procedures 34 * x8 PCI Express cards are supported, but will run at x4 speeds. CAUTION: To prevent damage to the server o

Página 29 - System fans

Removal and replacement procedures 35 6. Lift the air baffle up and out of the server. To replace the component, reverse the removal procedure. Ce

Página 30 - Redundant hot-plug fan cage

Removal and replacement procedures 36 8. Disconnect the fan cable from the system board. 9. Lift the center wall away from the chassis. To replace

Página 31

Removal and replacement procedures 37 CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are popu

Página 32 - Expansion slot cover

Removal and replacement procedures 38 8. Squeeze the two tabs securing the assembly from the inside, and slide the power button/LED assembly through

Página 33 - Expansion board

Removal and replacement procedures 39 8. Disconnect the diskette drive cable and power cable from the diskette drive. 9. Loosen the thumbscrews th

Página 34 - Processor air baffle

Contents 4 Cabling overview...

Página 35 - Center wall

Removal and replacement procedures 40 CAUTION: Do not mix the 2-MB L2 Cache processors with the 1-MB L2 Cache processors. To remove the component

Página 36 - CD-ROM drive

Removal and replacement procedures 41 a. Determine the correct processor orientation by observing the three guide pins on the processor retaining br

Página 37 - Power button/LED assembly

Removal and replacement procedures 42 3. Lower the processor retaining bracket into position over the processor. 4. Press the processor retaining

Página 38 - Diskette drive

Removal and replacement procedures 43 6. Remove the PPM. NOTE: The appearance of compatible PPMs may vary. CAUTION: Only install a PPM if the

Página 39 - Processor assembly

Removal and replacement procedures 44 6. Remove the DIMM. IMPORTANT: DIMMs do not seat fully if turned the wrong way. For DIMM configuration inf

Página 40

Removal and replacement procedures 45 7. Remove the SCSI backplane. To replace the component, reverse the removal procedure. Duplex SCSI board 1.

Página 41

Removal and replacement procedures 46 VHDCI or HD68 SCSI cable option The VHDCI or HD68 SCSI Cable connects the server to external SCSI-based storag

Página 42 - Processor power module (PPM)

Removal and replacement procedures 47 To replace the component, reverse the removal procedure. Power supply backplane To remove the component: 1.

Página 43

Removal and replacement procedures 48 10. Remove the power supply backplane. To replace the component, reverse the removal procedure. IMPORTANT:

Página 44 - SCSI backplane

Removal and replacement procedures 49 11. Lift the system board out of the chassis and tilt it to one side to clear the cable guide. To replace the

Página 45 - Duplex SCSI board

Contents 5 Acronyms and abbreviations... 79 Inde

Página 46

Removal and replacement procedures 50 5. Remove the battery. To replace the component, reverse the removal procedure. Run RBSU to configure the sys

Página 47 - Power supply backplane

Server cabling 51 Server cabling In this section Cabling overview...

Página 48 - System board

Server cabling 52 NOTE: The cables shown ship standard with the server. Item Component description SCSI IDs managed 1 SCSI cable (SCSI 1)

Página 49 - Battery

Server cabling 53 Item Component description SCSI IDs managed 2 SCSI cable (SCSI 2) * 4, 5 3 Duplex SCSI board N/A * One SCSI cable is provid

Página 50

Server cabling 54 Array controller simplex SCSI cabling In the array controller simplex SCSI cabling configuration, an optional PCI array controller

Página 51 - Server cabling

Server cabling 55 Item Component description SCSI IDs managed 2 SCSI cable * 4, 5 * One SCSI cable is provided with the server. Array controll

Página 52

Server cabling 56 • Power cables • Data cables

Página 53

Server cabling 57 CD-ROM drive cabling Item Cable description 1 CD-ROM drive power cable 2 CD-ROM drive data cable Diskette drive cabling

Página 54

Server cabling 58 External storage cabling With the optional cable kit, the server supports external storage devices through the Auxiliary VHDCI SCS

Página 55 - SAS cabling

Server cabling 59 IMPORTANT: Install the RILOE II board into slot 1 for ease of cabling.

Página 56 - Data cables

Illustrated parts catalog 6 Illustrated parts catalog In this section Customer self repair ...

Página 57 - Diskette drive cabling

Diagnostic tools 60 Diagnostic tools In this section Automatic Server Recovery...

Página 58 - RILOE II cabling

Diagnostic tools 61 • From within Survey Utility • From within operating system-specific IML viewers • For NetWare: IML Viewer • For Windows®: IM

Página 59 - Server cabling 59

Diagnostic tools 62 HP ROM-Based Setup Utility RBSU, an embedded configuration utility, performs a wide range of configuration activities that may i

Página 60 - Diagnostic tools

Diagnostic tools 63 • Preparing the system for installing "off-the-shelf" versions of leading operating system software • Installing opti

Página 61

Server component identification 64 Server component identification In this section Front panel components ...

Página 62 - SmartStart software

Server component identification 65 Item Description 8 Removable media bays 9 Hot-plug SCSI hard drive bays (SCSI IDs 0 through 5) 10 Optional SAS-

Página 63 - HP Insight Diagnostics

Server component identification 66 Rear panel components Item Description Item Description 1 x4 PCI Express expansion slots 9 Auxiliary VHDCI

Página 64 - Front panel components

Server component identification 67 Item Description LED color Status 1 Unit ID LED Blue On = Activated Flashing = System remotely managed Off

Página 65 - Front panel LEDs and buttons

Server component identification 68 System board components Item Description Item Description 1 Redundant fan 2 connector 13 Power supply conn

Página 66 - Rear panel LEDs and buttons

Server component identification 69 Position Description Function S1 iLO security Off = iLO security is enabled On = iLO security is disabled S2

Página 67

Illustrated parts catalog 7 Mechanical components Item Description Assembly Part Number Spare Part Number Customer Replaceable 1 Access panel

Página 68 - System board components

Server component identification 70 DIMM slots DIMM slots are numbered sequentially (1 through 8) and the paired banks are identified by the letters A

Página 69 - Power supply backplane LED

Server component identification 71 Item LED description Status 1 Processor error Off = Normal Amber = Processor failed or missing 2 System temp

Página 70 - System board LEDs

Server component identification 72 System LED and color Internal health LED color Status DIMM failure (all slots, Amber) Red • No valid or usable m

Página 71

Server component identification 73 SATA or SAS hard drive LEDs Item LED description Status 1 Fault/UID status Amber = Drive failure Flashing a

Página 72

Server component identification 74 Item Description Configuration 1 Fan 1 Primary 2 Fan 2 Redundant 3 Fan 3 Primary 4 Fan 4 Redundant 5 Fan 5

Página 73 - SATA or SAS hard drive LEDs

Specifications 75 Specifications In this section Server specifications...

Página 74 - Hot-plug fan LEDs

Specifications 76 Specification Value Relative humidity (noncondensing)** Operating 10% to 90% Non-operating 5% to 95% * All temperature ratings

Página 75 - Specifications

Specifications 77 Specification Value Sectors per track (high/low) 18/9 Tracks per side (high/low) 80/80 Access times Track-to-track (high/low) 3

Página 76

Specifications 78 Specification Value Divergence angle 53.5° ± 1.5° Output power 0.14 mW Operating conditions Temperature 5°C to 45°C (41°F to 11

Página 77 - CD-ROM drive specifications

Acronyms and abbreviations 79 Acronyms and abbreviations ABEND abnormal end ASR Automatic Server Recovery BIOS Basic Input/Output System DDR doub

Página 78

Illustrated parts catalog 8 System components Item Description Assembly Part Number Spare Part Number Customer Replaceable System Components

Página 79 - Acronyms and abbreviations

Acronyms and abbreviations 80 NMI non-maskable interrupt NVRAM non-volatile memory ORCA Option ROM Configuration for Arrays PCI Express periphera

Página 80

Acronyms and abbreviations 81 SDRAM synchronous dynamic RAM SIM Systems Insight Manager SNMP Simple Network Management Protocol UID unit identifi

Página 81

Index 82 A AC power supply 66 access panel 20 air baffle 15 array configuration 58 ASR (Automatic Server Recovery) 60, 79 Automatic Server

Página 82 - Index 82

Index 83 internal health LED 65, 71 K keyboard connector 66 L LED, fan 72, 74 LEDs 64, 72, 73, 74 LEDs, hard drive 72, 73 LEDs, SAS hard dr

Página 83 - Index 83

Index 84 system maintenance switch 68 system power connector 68 system power LED 65 Systems Insight Manager 60 T telco racks 15 temperature

Página 84 - Index 84

Illustrated parts catalog 9 Item Description Assembly Part Number Spare Part Number Customer Replaceable b) Intel® Xeon™ 3.2-GHz 1-MB L2 cache* 34

Comentários a estes Manuais

Sem comentários