HP ProLiant Generation ML310 Especificações Página 57

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 80
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 56
Removal and replacement procedures 57
7. Apply all the grease to the top of the processor in one of the following patterns to ensure even
distribution:
CAUTION: The heatsink is designed to fit one way in the server. Failure to install the heatsink
properly can result in thermal damage or equipment failure.
CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an
"X" pattern).
8. Align and install the heatsink with the arrow on the heatsink label pointing to the front of the server.
9. Connect the processor heatsink fan cable to the system board ("System board components" on page
68). When the heatsink is oriented properly, cable length is sufficient for the corresponding
connector.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
Vista de página 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 79 80

Comentários a estes Manuais

Sem comentários