Power Over Ethernet (PoE) Operation
Configuring PoE Operation
Disabling or Re-Enabling PoE Port Operation
Syntax: [no] interface [e] < port-list > power
Re-enables PoE operation on < port-list > and restores the priority
setting in effect when PoE was disabled on < port-list >. The [no]
form of the command disables PoE operation on < port-list >.
(Default: All xl PoE ports on the module are enabled for PoE
operation at Low priority.)
Changing the Threshold for Generating a Power Notice
Syntax: power [slot < slot-identifier >] threshold < 1 - 99 >
This command specifies the PoE usage level (as a percentage of the
PoE power available on a module) at which the switch generates a
power usage notice. This notice appears as an SNMP trap and a
corresponding Event Log message, and occurs when an xl PoE
module’s power consumption crosses the configured threshold value.
That is, the switch generates a notice whenever the power
consumption on a module either exceeds or drops below the specified
percentage of the total PoE power available on the module.
This command configures the notification threshold for PoE power
usage on either a global or per-module (slot) basis.
Without the [slot < slot-identifier >] option, the switch applies one
power threshold setting on all PoE modules installed in the switch.
For example, suppose slots A, B, and C each have an xl PoE module
installed. In this case, executing the following command sets the
global notification threshold to 70% of available PoE power.
HPswitch(config)# power threshold 70
With this setting, if an increasing PoE power demand crosses this
threshold on the module in slot B, the switch sends an SNMP trap
and generates this Event Log message:
Slot B POE usage has exceeded threshold of 70 %.
If the switch is configured for debug logging, it also sends the Event
Log message to the configured debug destination(s).
On any PoE module, if an increasing PoE power load (1) exceeds
the configured power threshold (which triggers the log message and
SNMP trap), and then (2) later decreases and drops below the
threshold again, the switch generates another SNMP trap, plus a
message to the Event Log and any configured Debug destinations.
— Continued —
11-11
Vista de página 198
1 2 ... 194 195 196 197 198 199 200 201 202 203 204 ... 441 442

Comentários a estes Manuais

Sem comentários

Dirt Devil Factory M3330 manuales

Manuales del propietario y guías del usuario para Aspiradoras Dirt Devil Factory M3330.
Ofrecemos 1 manuales en pdf Dirt Devil Factory M3330 para descargar gratis por tipos de documentos: Manual de servicio






Más productos y manuales para Aspiradoras Dirt Devil

Modelos Tipo de documento
M680-1 Trendino Manual de servicio     Dirt Devil M680-1 Trendino, 27 paginas
Vito Plus Manual de servicio     Dirt Devil Vito Plus, 24 paginas
Platinum Force El manual del propietario   Dirt Devil Platinum Force Owner`s manual, 12 paginas
BD10167 Manual de uso y cuidado     Dirt Devil BD10167 Use and Care Manual, 2 paginas
BD20035RED Manual de uso y cuidado    Dirt Devil BD20035RED Use and Care Manual [en] [et] [it] [it] , 2 paginas
SD40050B Manual de uso y cuidado     Dirt Devil SD40050B Use and Care Manual, 14 paginas
UD70300B Manual de uso y cuidado     Dirt Devil UD70300B Use and Care Manual, 34 paginas
SD12000 Manual de uso y cuidado     Dirt Devil SD12000 Use and Care Manual, 12 paginas
UD20015 Manual de uso y cuidado     Dirt Devil UD20015 Use and Care Manual, 14 paginas
BD20050 Manual de uso y cuidado      Dirt Devil BD20050 Use and Care Manual, 8 paginas
SD12515B Manual de uso y cuidado     Dirt Devil SD12515B Use and Care Manual, 60 paginas
SD20000RED Manual de uso y cuidado    Dirt Devil SD20000RED Use and Care Manual, 2 paginas
UD70250B Manual de uso y cuidado    Dirt Devil UD70250B Use and Care Manual, 18 paginas
FD50110 Manual de uso y cuidado   Dirt Devil FD50110 Use and Care Manual, 20 paginas