set fcoe-connection
The -set fcoe-connection command modifies an existing FCoE connection.
Syntax
set fcoe-connection –profilename <profileName>
-portnumber <PortNumber>
[-fabric <FabricName>]
[-speedtype <1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]
[–customspeed <100–10000>]
[–bootpriority <priority>]
[–bootport <portName>]
[–bootlun <LUN>]
Parameters
Table 15 Parameter descriptions for -set fcoe-connection
OptionalRequiredDescriptionParameter
xThe name of the profile to
which the FcOE connection
will be assigned.
-profilename
xThe port number of the
connection.
-portnumber
xThe name of the FCoE SAN
fabric to associate with the
connection.
-fabric
xThe requested operational
speed for the server port.
-speedtype
Valid values include 1Gb,
2Gb, 4Gb,8Gb, custom,
and disabled. If the speed
type is custom, you can
configure any speed from
100Mb-10Gb in 100Mb
increments. The
-customspeed parameter
is required if the speed type
is custom and is the
user-defined speed for the
server port. Valid values
include 100Mb-10Gb
configured in 100Mb
increments The acceptable
value is 100 to 10000
Mb/s.
x
IMPORTANT: The
-customspeed parameter
is required if the speed type
is custom.
User-defined speed for the
server port. Valid values
include 100Mb-10Gb
configured in 100Mb
increments The acceptable
value is 100 to 10000
Mb/s.
-customspeed
xControls whether the FC
HBA port is enabled for
-bootpriority
SAN boot and affects the
BIOS boot order. Valid
values include the following:
• Usebios