P2000/MSA2000—System name
P9000/XP—Array serial number
Array Type—HP array type
Datastore/RDM—Datastore name or the associated .vmdk name for the RDM
Type—Disk type (Datastore or RDM)
Paths—Number of paths to the disk
VMware Disk Identifier—Disk name assigned by VMware
Path ID—Path ID assigned by VMware
Array Disk RAID—RAID level of the array disk
Array Disk Total Capacity—Array disk capacity (in bytes)
Array Disk Allocated —Capacity allocated by the storage system (in bytes)
For a thin-provisioned disk, this value might differ from the Array Disk Total Capacity value.
Array Disk Provisioned—Specifies whether the disk is thin provisioned or normal (not supported
on P2000/MSA2000)
Array Disk Type—Array disk type
Storage Pool
P4000—Name of the cluster.
3PAR—Disk group where the vdisk is located.
P6000 EVA—Disk group where the vdisk is located.
This value is displayed only when demand allocated snapshots are used. For other volume
types, no value is displayed.
P2000/MSA2000—Name of the vdisk or snap pool where the volume is located.
P9000/XP—Disk group or storage pool used for allocating storage to the disk. This might
be a P9000 or XP Thin Provisioning pool, a P9000 or XP Snapshot pool, an internal
parity group, or an external group.
Storage Pool Available Capacity
P4000—Unallocated space in the storage pool (cluster) that can be used to meet storage
needs for a snapshot or thin-provisioned volume. The calculation of this value assumes
all unallocated space is formatted the same as this volume. For all other volume types,
no value is displayed.
3PAR—Unallocated space in the storage pool that can be used to meet storage needs
for a snapshot or thin-provisioned volume. For all other volume types, no value is displayed.
The calculation of this value assumes that all disk space uses the same RAID type as this
volume.
P6000 EVA—Unallocated space in the storage pool that can be used to meet storage
needs for a snapshot or thin-provisioned volume. For all other volume types, no value is
displayed. The calculation of this value assumes that all disk space uses the same RAID
type as this volume.
P2000/MSA2000—Unallocated space in the storage pool (cluster) that can be used to
meet storage needs for a snapshot or thin-provisioned volume. The calculation of this
50 Using Insight Control for vCenter