Hp OneView for VMware vCenter Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Software Hp OneView for VMware vCenter. HP OneView for VMware vCenter User Manual [en] [es] [fr] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
HP Insight Control for VMware vCenter
Server User Guide
Abstract
This document contains detailed instructions for configuring and using HP Insight Control for VMware vCenter Server. It is
intended for system administrators who are experienced in virtual and physical IT infrastructure administration and understand
server virtualization, storage, and networking concepts.
HP Part Number: 678315-003
Published: May 2013
Edition: 1
Vista de página 0
1 2 3 4 5 6 ... 112 113

Resumo do Conteúdo

Página 1 - Server User Guide

HP Insight Control for VMware vCenterServer User GuideAbstractThis document contains detailed instructions for configuring and using HP Insight Contro

Página 2

The home page allows you to access the following server administration pages.• Server Password ManagementThe Server Password Management page allows yo

Página 3 - Contents

Action: Complete the following procedure:1. Open the configuration.json file, which is located in the install folder\uim(assuming that the default ins

Página 4 - 4 Contents

5. Select the following:• Operation: Restart• Controller type: Management• Controller: A or B, as determined in Step 36. Click Restart now.7. Log in t

Página 5 - Contents 5

3. Click Advanced Settings in the Software pane.4. Click Scsi in the list of advanced settings.5. Edit the Scsi.CompareLUNNumber value, and then click

Página 6 - 6 Contents

Cannot configure HP MSA P2000 G3 array when using user-created accountWhen configuring HP MSA P2000 G3 arrays, an Unable to Authenticate error occurs.

Página 7 - 1 Overview

7 Support and other resourcesThis chapter describes the support available for Insight Control for vCenter.Information to collect before contacting HPB

Página 8

HP authorized resellersFor the name of the nearest HP authorized reseller, see the following sources:• In the United States, see the HP U.S. service l

Página 9 - Role-based security

8 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve thedocumentation, send any errors, sugges

Página 10 - Manual association

A Firewall port requirementsTo achieve full functionality, an Insight Control for vCenter server requires that the firewall portsselected or configure

Página 11 - Accessing management tools

GlossaryCIM Common Information Model.CLI Command-line interface. An interface comprised of various commands which are used to controloperating system

Página 12

SMU Storage Management Utility. The web browser interface that system administrators can use toconfigure, monitor, and manage MSA2000 Family storage s

Página 13 - Storage Module” (page 46)

3. Enter the iLO IP address or host name, and a user name and password.Onboard Administrator Single Sign-OnTo enable SSO, you must upload the Insight

Página 14 - Adding HP 3PAR StoreServ

IndexAaccessing HP Insight Control for vCenter, 25adding arraysHP StoreOnce Backup, 19adding management serversHP EVA Command View, 15adding storage s

Página 15

health status, 97health status information missing, 97hostinfrastructure information, 39network information, 39overview page, 38viewing information, 3

Página 16 - Adding HP EVAs

portlets, 30portstroubleshooting, 100Power Control, 43power costsetting, 32power events, 89power subsystem events, 88, 89power supply events, 88, 89po

Página 17

datastore storage information, 55HBAs, 61host storage information, 51management servers, 19paths, 61replications, 64storage systems, 19storage volumes

Página 18 - Adding HP XP storage systems

new VMs, or cloning existing VMs on storage pools that are set to Full Access. For more information,see “Provisioning storage” (page 70).To access the

Página 19 - Adding HP StoreOnce Backup

4. Verify the configuration of the storage systems.For example, select a host, and navigate to the Storage Details page. Confirm that the HPInsight Ma

Página 20

Adding HP StoreVirtual storage systemsTo add an HP StoreVirtual storage system (also called a management group):1. Access the Storage Administrator Po

Página 21

6. Select the Full Access check box for one or more storage pools to enable provisioning by theStorage Module for vCenter.Storage pools do not need to

Página 22

Adding HP EVAsTo view information about an HP EVA, use the Storage Administrator Portal to add the storagesystem and associate it with a HP EVA Comman

Página 23

2. Ensure that the HP MSA 2000 G2 SMI-S proxy provider is installed on the same server as theStorage Module for vCenter.The Insight Control for vCente

Página 24

6. Click Next.The Add HP MSA P2000 G3 page appears, listing the storage pools on the selected HP MSAP2000 G3 System.7. Select the Full Access check bo

Página 25

6. Enter the Remote Web Console credentials, and then click Finish.The storage system is added to the Configured Storage Systems and Management Server

Página 26

© Copyright 2012, 2013 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or

Página 27

◦ HP EVA—Storage system WWN◦ HP MSA 2000 G2/HP MSA P2000 G3—Storage system serial number◦ HP XP/HP XP P9000—Storage system serial number◦ HP StoreOnce

Página 28 - HP Insight Management pages

data for that storage system or management server. Disks from the removed storage system aredisplayed as unmanaged disks in the vSphere Client.Conside

Página 29

• Login: Enter the login information for the system that runs the vSphere Client.• Password: Enter the password for the system that runs the vSphere C

Página 30

5. Enter the following information in the Certificate Info section:• Country• State• Locality• Organization• Common Name—The fully qualified vCenter S

Página 31

3 Using Insight Control for vCenterThis chapter describes the processes for accessing and using the software.You can access resource inventory, HP Ins

Página 32 - Prerequisites

Accessing Insight Control for vCenterAfter completing the installation and configuration procedures, you can access Insight Control forvCenter two way

Página 33

Figure 5 vSphere Web Client — OverviewComparing vSphere Client to vSphere Web Client integrationvSphere Web ClientvSphere ClientUses a series of tabsU

Página 34 - Managing clusters

NotesDifference compared to vSphere ClientvSphere Web Client itemxxxyyyyzzzz for the same event. Youcan use the Task portlet to view the taskdetails.U

Página 35

4. Click the HP Insight Management tab.An overview of the VMware component that you selected appears. While Insight Control forVMware vCenter collects

Página 36 - Viewing cluster information

• Storage• News Feed (a list of recent events)For detailed information about portlet items, do one of the following:• Click More at the bottom of the

Página 37 - Managing servers

Contents1 Overview...72 Configuring Insight Control for

Página 38 - Host Overview page

◦ Host◦ Cluster◦ Networking◦ Infrastructure◦ Storage◦ Software/FirmwareThe bottom of the HP Insight Management pages shows:• Links to launch HP Manage

Página 39 - Viewing host information

Navigating HP Insight Management with the Server ModuleInformation from iLO, Onboard Administrator, HP SNMP agents, HP CIM providers, and VirtualConne

Página 40 - Host network configuration

Setting the power cost for a clusterBefore entering the power cost settings for a cluster, ensure that the cluster meets the followingrequirements:• T

Página 41

4. For the network interface, do one of the following, and then click Next:• Select the DHCP check box.• Enter a static IP address, network domain, ga

Página 42 - Using the network diagram

A summary screen is displayed.4. Click Submit.Setting host network configuration preferencesThese settings are used to evaluate the network configurat

Página 43 - Rediscovering devices

Figure 6 Cluster overview page (vSphere Client)Figure 7 Cluster overview page (vSphere Web Client)The Overview page for Cluster Management displays st

Página 44 - Viewing news feed information

NOTE: With the exception of Virtual Connect Manager, administrators can launch tools withoutproviding login credentials.Cluster Overview pageThe Clust

Página 45 - Launching into HP tools

2. For detailed cluster infrastructure information, click More at the bottom of the Infrastructureportlet or do one of the following:• From the vSpher

Página 46 - Managing VMs

Figure 9 Host Overview page — vSphere Web Client viewDepending on the software installed, links are available to launch HP tools.Host Overview pageThe

Página 47 - Manually refreshing the cache

For more information, see “Navigating HP Insight Management with the Storage Module” (page 46).Viewing host informationTo view information about the h

Página 48 - Restarting a cache refresh

Viewing cluster infrastructure information...36Viewing software and firmware on

Página 49

1. Select a server in the inventory tree, and then access HP Insight Management.The Networking portlet on the Overview page provides an overview of th

Página 50 - ◦ Resized column widths

actions are included for configuring the VMware host network based on the network preferenceand Virtual Connect networks.• The Virtual Connect profile

Página 51 - Viewing summary information

NOTE:• This feature is available only on the vSphere Web Client.• Only blade servers are supported as a reference host.• Ensure that no host configura

Página 52

Figure 10 Virtual Connect Network DiagramViewing host software and firmwareNOTE: Firmware information is available for ESXi systems with the HP Offlin

Página 53 - Viewing detailed information

To use this feature, select Rediscover Node from the Actions drop-down list.Using HP VMware ESXi Smart ComponentsHP Smart Components can be used to up

Página 54

2. For detailed news feed information, click More at the bottom of the News Feed portlet or doone of the following:• From the vSphere Client, select N

Página 55

• Insight Control power management• Virtual Connect Enterprise Manager• HP storage system management utilitiesWhen configured for vCenter administrato

Página 56

Refreshing Storage Module for vCenter dataAfter installation, the Storage Module collects information about the VMware environment and theHP storage s

Página 57

Using HP Insight Management1. Click the cache refresh icon . In the vSphere Client this icon is located in the top rightcorner of any storage page.HP

Página 58 - Viewing storage volumes

Restarting a cache refresh using the Storage Administrator portal1. Click the Refresh Cache link in the top right corner of the Storage Administrator

Página 59

5 Viewing hardware alert notifications...87Insight Control for vCenter events...

Página 60 - Related topics

• In the vSphere Client, click the heading of a column and drag the column to a different locationin the table.• Click Save Column Settings to save th

Página 61 - Viewing paths

A list of the columns is displayed. See Figure 15 (page 51).• Check the box next to a column to display it. Click Select All to select all the columns

Página 62

NOTE: The HP Storage Used value can differ from the HP Storage Provisioned value if thinprovisioning or demand-allocated snapshots are used.• HP Stora

Página 63

DatastoresThis section lists the datastores provisioned from the selected host to VMs. For each datastore,move the cursor over the status bar to view

Página 64 - Viewing replications

• HP Storage ThP Savings—Amount of storage saved through the use of array-based thinprovisioning• Volumes overprovisioned—Number of over-provisioned v

Página 65 - Viewing VMs to volumes

This section lists the datastores provisioned from the selected host to VMs. For each datastore,move the cursor over the status bar to view storage in

Página 66

Provisioned from Datastore to Virtual Machines• Current storage inventory—Number of datastores, RDMs, and unused volumes provisionedto VMs• Datastore

Página 67

Viewing storage information of a virtual machineTo view storage information for a VM:1. Select a VM in the inventory tree and access HP Insight Manage

Página 68

• Used—Amount of storage used on the host as virtual disks (VMDKs or RDMs)• % Savings—Amount of storage saved through the use of VMware thin provision

Página 69

◦ HP XP P9000/HP XP—LDKC:CU:LDEV (for example, HP OPEN-V-CVS (00:04:3F))◦ HP StoreOnce Backup—Not applicable• Array NameHP StoreVirtual—Management gro

Página 70 - 4 Provisioning storage

7 Support and other resources...104Information to collect before contacting HP...

Página 71 - Creating a datastore

assumes all unallocated space is formatted the same as this volume. For all other volumetypes, no value is displayed.◦ HP 3PAR StoreServ—Unallocated s

Página 72 - 72 Provisioning storage

Viewing virtual disksThe virtual disks page displays the following information:• Virtual Disk Name—Virtual disk name assigned by VMware• Virtual Disk

Página 73 - 6. Click Next

◦ HP XP P9000/HP XP—Array serial number◦ HP StoreOnce Backup—Not applicable• Host HBA Port WWN/IQNHP StoreVirtual—IQN assigned to the host◦◦ HP 3PAR S

Página 74 - 74 Provisioning storage

◦ HP XP P9000/HP XP—Port number◦ HP StoreOnce Backup—Not applicable• Host GroupHP StoreVirtual—Name configured for the host's IQN in the manageme

Página 75 - Expanding a datastore

• Host ModeHP StoreVirtual—Not applicable◦◦ HP 3PAR StoreServ—Not applicable◦ HP EVA—Host mode assigned to the HP EVA host object◦ HP MSA 2000 G2/HP M

Página 76 - Deleting a datastore

• Replication GroupHP StoreVirtual—Not applicable◦◦ HP 3PAR StoreServ—Remote Copy group name◦ HP XP P9000/HP XP—Replica group ID◦ HP EVA—Data replicat

Página 77 - Creating a VM from a template

◦ HP XP P9000/HP XP—Emulation type and LDKC:CU:LDEV (for example, HP OPEN-V-CVS(00:04:3F))◦ HP StoreOnce Backup—Not applicable• Array Disk Type—Array

Página 78 - 78 Provisioning storage

NOTE: The HP XP P9000/HP XP array does not allow host access to be specified ona per-host or per-path basis.◦ HP StoreOnce Backup—Not applicable• Host

Página 79

• LUN Number—LUN used for presenting the storage disk from the storage system port to thehost HBA port• Path ID—Path ID assigned by VMware• Preferred

Página 80 - 80 Provisioning storage

Using the HP Infrastructure pageThe HP Infrastructure page displays information for all storage systems configured in the plug-in’senvironment. The nu

Página 81

1 OverviewHP Insight Control for VMware vCenter Server (Insight Control for vCenter) is a single integratedapplication that you use to manage ProLiant

Página 82 - Cloning a VM

4 Provisioning storageThe Storage Module for vCenter supports storage provisioning for HP 3PAR StoreServ, HPStoreVirtual, HP EVA, and HP MSA P2000 G3

Página 83 - Cloning a VM 83

Viewing the audit logThe Storage Module for vCenter provides an audit log for provisioning operations. The audit log,provisionAuditLog.txt, is availab

Página 84 - 84 Provisioning storage

3. Enter the following information:• Quantity: Enter the number of datastores to create.• Datastore Capacity: Enter the capacity for the new datastore

Página 85 - Cloning a VM 85

5. Select the copy space for the HP 3PAR StoreServ.6. Click Next.The Create Datastores – Specify New Names window opens.Creating a datastore 73

Página 86 - Client window

7. Enter the following information:• New Datastore Names: Enter the base name for the new datastores. The # symbol isrequired and represents the numer

Página 87 - Onboard Administrator events

11. Click Finish to create the specified datastores.You can view the progress of the task in the Recent Tasks pane at the bottom of the vSphereClient

Página 88

3. Enter the new capacity in the Requested Datastore Capacity box.The following rules apply when expanding datastores:• A datastore can be expanded on

Página 89

• In the vSphere Client, select Delete Datastore from the Actions drop-down list.• Select a datastore in the inventory tree, click Storage Tools in th

Página 90

NOTE: When VMware converts a VM to a template, all RDMs are converted to empty virtualdisks (VMDKs). Therefore, VMs created from this template will no

Página 91 - Alarm icon

4. Click Next.The Create Virtual Machines – Specify Storage window opens.5. Enter the following information:• Quantity: The number of datastores to cr

Página 92 - 6 Troubleshooting

2 Configuring Insight Control for vCenterInsight Control for vCenter is managed as a plug-in in the vCenter Server environment. Severalsettings can im

Página 93

7. Enter the following information:• VM Names: Enter the base name for the new VMs. The # symbol is required and representsthe numeric sequence for th

Página 94 - 94 Troubleshooting

9. Click Next to validate that it is possible to create the VMs.The Create Virtual Machines – Review and Validate window is updated with icons showing

Página 95

11. Click Finish to create the specified VMs and datastores.You can view the progress of the task in the Recent Tasks pane at the bottom of the vSpher

Página 96 - 96 Troubleshooting

• In the vSphere Client, select Clone VM from the Actions drop-down list.• Right-click a VM in any Storage Module for vCenter table, and then select C

Página 97

5. Enter the following information:• New VM Names: Enter the base name for the new VMs. The # symbol is required andrepresents the numeric sequence fo

Página 98 - 98 Troubleshooting

7. Click Next to validate that it is possible to create the cloned VMs.The Review and Validate window is updated with icons showing the success or fai

Página 99

9. Click Finish to create the specified VMs.You can view the progress of the task in the Recent Tasks pane at the bottom of the vSphereClient window.T

Página 100 - Module GUI

5 Viewing hardware alert notificationsThis chapter describes the Insight Control for vCenter hardware alert events and alarms.Insight Control for vCen

Página 101

For more information, see the HP BladeSystem Onboard Administrator User Guide, which isavailable on the HP website: http://www.hp.com/go/oa.vCenter Se

Página 102 - 102 Troubleshooting

Enclosure name: Blade in bay number: iLO deadInterconnect eventsEnclosure name: Interconnect in bay number status changed to unknown.Enclosure name: I

Página 103

IMPORTANT:• If you have a Proxy-enabled Windows client and an ESXi host using iLO or other managementsoftware, you must disable or bypass the Proxy Se

Página 104 - 7 Support and other resources

Enclosure name: Power subsystem status changed to non-recoverable error.Enclosure name: Power subsystem status changed to predictive failure.Enclosure

Página 105 - Related information

• Alarms associated with HP ProLiant and HP BladeSystem fan zonesThese alarms are triggered by an HP BladeSystem subsystem event. The alarm states are

Página 106 - 8 Documentation feedback

6 TroubleshootingBefore troubleshooting issues with Insight Control for vCenter, you must do the following:• Verify that the correct user name and pas

Página 107 - A Firewall port requirements

HP Insight Management tab not available in the vSphere Web ClientPossible cause: The vSphere Web Client has not deployed the plug-in.NOTE: The plug-in

Página 108 - Glossary

• HP Insight Control Storage Module for vCenter• HP Insight Control for vCenter UI ManagerSlow response in the vSphere ClientPossible cause: The syste

Página 109

Error Communicating with iLO at VM hostThe following error appears if the Windows Proxy Server is enabled and the ESX host is using iLO3:Error Communi

Página 110 - 110 Index

3. Rename <export folder>\icvc\uim\share\db_7.2 to <exportfolder>\icvc\uim\share\db4. Install Insight Control for vCenter version 7.2.Trou

Página 111

Health status or information is missing for specific hosts or clustersPossible cause: Active and properly authenticated communication between vCenter

Página 112 - 112 Index

Microsoft Windows 2008 Internet Explorer Enhanced Security can also block cookies. Be sure tochange the security settings to enable cookies in Server

Página 113

There are no firmware components to display. The HP ESXi Offline Bundle for VMware is not installed on this host.• If some other error occurs, the fol

Comentários a estes Manuais

Sem comentários