Table 35 iSCSI or iSCSI/FCoE module log messages (continued)
iSCSI session full feature login.InfoAppQLIS_LoginPduContinue:
[0x%x] SES_STATE_LOGGED_IN
NORMAL
53584
iSCSI session discovery login.InfoAppQLIS_LoginPduContinue:
[0x%x] SES_STATE_LOGGED_IN
DISCOVERY
53585
iSCSI login of Initiator: %s.InfoAppQLIS_LoginPduContinue:
Initiator: %s
53586
iSCSI login of Target: %s.InfoAppQLIS_LoginPduContinue:
Target: %s
53587
FC login occurred, origin xx (1 = adapter, 2 =
target, 3 = initiator), VP (virtual port) xx, ID (loop
ID) xx.
InfoAppQLFC_Login: Origin 0x%x, VP
Index 0x%x, Id 0x%x
54274
FC login occurred with port ID xx.xx.xx.InfoAppQLFC_Login: Port ID
%.2x%.2x%.2x
54275
FC login occurred with WWNN
xx.xx.xx.xx.xx.xx.xx.xx.
InfoAppQLFC_Login: Node Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54276
FC login occurred with WWPN
xx.xx.xx.xx.xx.xx.xx.xx.
InfoAppQLFC_Login: Port Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54277
QLFC_Logout: Origin 0x%x, VP Index 0x%x, Id
0x%x
InfoAppQLFC_Logout: Origin 0x%x,
VP Index 0x%x, Id 0x%x
54306
FC Logout: Port ID %.2x%.2x%.2x.InfoAppQLFC_Logout: Port ID
%.2x%.2x%.2x
54307
FC Logout: Node Name xx xx xx xx xx xx xx xx.InfoAppQLFC_Logout: Node Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54308
FC Logout: Port Name xx xx xx xx xx xx xx xx.InfoAppQLFC_Logout: Port Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54309
FC login event notification, VP (virtual port) xx.InfoAppQLFC_Logout: Port Name
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
54359
iSCSI target connection opened for port %d, data
description block (DDB) %d.
InfoAppQLIS_OpenConnectionNotification:
Target connection opened
(Port %d, DDB %d)
54683
Event notification; iSCSI open connection request.InfoAppQLIS_OpenConnectionNotification:
Target connection opened
(Port %d, DDB %d)
54938
Event notification; iSCSI close connection request
or connection closed.
InfoAppQLIS_HandleTeb:
UTM_EC_CLOSE_CONNECTION or
UTM_EC_CONNECTION_CLOSED
54939
Event notification; iSCSI connection closed.InfoAppQLIS_HandleTeb:
UTM_EC_CLOSE_CONNECTION or
UTM_EC_CONNECTION_CLOSED
54940
Event notification; connection opened with iSNS
server.
InfoAppQLIS_HandleTeb:iSNS Server
Open Connection succeeded
54941
Event notification; iSNS registered state change
notification (RSCN) received.
InfoAppQLIS_HandleTeb:
UTM_EC_ISNS_SCN
54943
Event notification; iSNS client discovered.InfoAppQLIS_HandleTeb:
UTM_EC_ISNS_CLIENT_DISCOVERED
54945
iSCSI processor SRAM test failed.FataliSCSI#%d: qlutm_init: Diagnostic
failed, invalid SRAM
69652
288 iSCSI and iSCSI/FCoE module log messages