Delete SAN profile
To delete a SAN profile:
1. Select any deactive SAN profile in the Manage SAN Profiles page.
2. Click Delete.
3. The Delete SAN Profile window is displayed with the following message:
Do you wish to delete the SAN Profile – XYZ (name of the SAN profile)
• Click Yes to delete the SAN profile.
• Click No to cancel the deletion.
NOTE: An active profile cannot be deleted.
Rescan SAN
Clicking on Rescan SAN initiates a data collection cycle for the active profile. This data collection
cycle is different than a system initiated cycle that occurs at an interval as set in the active profile.
Initiating a Rescan SAN request while the system initiated data collection cycle is in progress, the
system does not create a separate data collection cycle for rescan instead, the rescan is considered
as completed when the system initiated cycle ends.
To rescan a SAN profile, complete the following steps:
• Click Rescan SAN from the navigation menu.
NOTE:
• Rescan SAN works only on an active profile.
• Data collection timeout is 30 minutes. However, the GUI will timeout after 40 mins if the rescan
is not complete for any reason.
HP IIAS terminologies
Table 4 (page 23) lists the component types and their definitions. A component can be SAN Switch,
Host, or Storage.
Table 4 Component type and definition
DefinitionComponent type
Discovered Component
• A component is of vendor/model as per the “Support
Matrix” (page 53).
• The firmware version is not as per the requirements
mentioned in the Support Matrix.
• The component has current firmware version but not
selected by the user for monitoring.
Monitored Component
• A component is of vendor/model as per the Support
Matrix.
• The current firmware version as per the requirements
mentioned in Support Matrix is selected by the user for
monitoring.
A component connected to a ‘Discovered Switch’ or
‘Monitored Switch’ with any of the following conditions:
Inferred Component
• Is a switch without a valid IP address.
• Is a switch that contains only fiber channel connectivity.
• A switch has a valid IP address but the user credentials
entered in the profile does not apply to the switch.
Rescan SAN 23