Edge Switch Element Manager user guide 53
• 07 Non-HP switch at other end of the ISL—The cable is connected to a non-HP
switch, and interop mode is set to Open Fabric 1.0 mode.
• 08 ISL connection not allowed on this port—The port type configuration
does not match the actual port use. (The port is configured as an F_Port, but attaches to a
switch or director.)
• 10 Port binding violation - Unauthorized WWN—The WWN entered to
configure Port Binding for this port is not valid, or a nickname was used that is not
configured for the attached device in the Element Manager.
• 11 Unresponsive node connected to port—Possible causes are:
• Hardware problem on switch or on a connected node where ELP frames are not
delivered, the response is not received, or a fabric login (FLOGI) cannot be received.
There may be problems in the switch SBAR.
• Faulty or dirty cable connection.
• Faulty host bus adapters that do not send out FLOGI within a reasonable time frame.
• 0x0C ESA Security Mismatch—Processing of Exchange Security Attribute Frame
detected required security feature mismatch.
• 0x0D Fabric Binding Mismatch—Fabric Binding is enabled and detected a switch
connection with an incompatible fabric membership list. Could also be the result of
problems delivering EFMD ILS.
• 0x0E Authorization Failure Reject—The switch on the other side of the ISL
detected a security violation. This switch receives notification via a generic reject reason
code and sets its port to the invalid attachment state in sympathy.
• 0x0F Unauthorized Switch Binding WWN—A Switch Binding error was detected on
either an E_Port or F_Port.
• 0x10 Authentication Failure. ISL Authentication Check (CHAP) failed—If you wish
to allow the connection, update the authentication lists or disable authentication.
• 0x11 Fabric Mode Mismatch—A connection was not allowed because:
• An HP M-Series switch or director attempted to connect to an HP switch or director
running in Open Fabric mode.
• An HP M-Series switch or director running in Open Fabric mode attempted to connect to
another vendor’s switch or director with an incorrect ELP revision level.
• 0x12 CNT WAN Extension Mode Mismatch—The ELP maximum frame sizes were
incompatible because one product running in CNT WAN extension mode attempted to
connect to another product running in a normal mode.
Segmented E_Port messages:
• Incompatible operating parameters, such as resource allocation
time-out values (R_A_TOV) or error-detect time-out values
(E_D_TOV) are inconsistent—See ”Configuring operating parameters” on page 79
for more information.
• Duplicate domain IDs—See ”Configuring operating parameters” on page 79 for more
information.