HP 2312fc and 2324fc Modular Smart Array user guide 25
1. From your network administrator obtain an IP address, subnet mask, and gateway address for
controller A and controller B.
2. Use the provided micro-DB9 serial cable to connect controller A to a serial port on a host computer.
Your package contents include a micro-DB9-to-DB9 serial cable. If necessary, use a DB9-to-DB25 adapter
(not included) for connecting the serial cable to a DB25 serial port on the host computer.
3. Start and configure a terminal emulator, such as HyperTerminal or VT-100, using the display settings in
Table 3 and the connection settings in Table 4.
.
4. In the terminal emulator, connect to controller A.
5. Press Enter to display the CLI prompt (#).
Table 3 Terminal emulator display settings
Parameter Value
Terminal emulation mode VT-100 or ANSI (for color support)
Font Terminal
Translations None
Columns 80
Table 4 Terminal emulator connection settings
Parameter Value
Connector COM1 (typically)
Baud rate 115,200
Data bits 8
Parity None
Stop bits 1
Flow control None