Hp StorageWorks 500 G2 Modular Smart Array Manual do Utilizador Página 111

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 110
Troubleshooting 111
90 RIS Version Exceeded
Type: Error
Description: The controller has detected a version of the RIS that it does not
support.
Action: Remove the added volumes.
100 Volume #<n> State OK
Type: Informational
Description: The configured volume has returned to its normal operating state.
This condition typically occurs after a rebuild operation is complete.
Action: None
101 Volume #<n> State Failed
Type: Informational
Description: The controller failed the configured volume because too many
physical drives have failed, exceeding the fault tolerance level. The data on the
configured volume is no longer available.
Action: None