SFS20 RAID5 and ADG performance B–7
Each array populated with twelve 250GB disks, configured as one 2TB LUN with ADG (RAID6)
redundancy
Voltaire InfiniBand interconnect
RAID5 configuration
Four SFS20 arrays attached to each Object Storage Server
Each array populated with eleven 250GB disks, configured as one 2TB LUN with RAID5
redundancy
Voltaire InfiniBand interconnect
All results are based on tests using new, empty file systems with default MDS and OST mount options and
without quotas enabled.
Each client node writes a single file of 4GB with one and four stripes to a single Object Storage Server.
As a rule of thumb, write operations are slower when ADG redundancy is used than when RAID5
redundancy is used; read operations are roughly equivalent.