HP StorageWorks
XP24000/XP20000 LUN Manager User
Guide
Abstract
This guide explains how to define paths between hosts and logical volumes, a prerequisite for storing data on an HP
StorageWorks XP24000/XP20000 storage system. Other topics include configuring ports, controlling host access to volumes,
specifying command devices, and using spreadsheets to configure the storage system. The intended audience is a storage
system administrator or authorized service provider with independent knowledge of HP StorageWorks XP storage systems and
Remote Web Console.
HP Part Number: T5214-96092
Published: May 2011
Edition: Twelfth
Vista de página 0
1 2 3 4 5 6 ... 111 112

Resumo do Conteúdo

Página 1 - HP StorageWorks

HP StorageWorksXP24000/XP20000 LUN Manager UserGuideAbstractThis guide explains how to define paths between hosts and logical volumes, a prerequisite

Página 2

Figure 2 Enabling LUN SecurityUsually, you do not need to disable LUN security on ports. If LUN security is disabled on a port,the connected hosts wil

Página 3 - Contents

Figure 53 Concept of Host Mode OptionFigure 54 Example of Host Mode OptionTable 16 Binary to Hexadecimal ConversionHexadecimalNumberBinary NumberHexad

Página 4 - 4 Contents

Table 17 Available Configuration Values for the [WWN] TagAvailable ValuesItemColumnOne of the following can be set (Maximum number of ports is 256):1A

Página 5 - Contents 5

Table 18 Available Configuration Values for the [LUN] TagAvailable ValuesItemColumnOne of the following can be set (Maximum number of ports is 256):1A

Página 6 - Overview of LUN Security

Table 19 Available Configuration Values for the [LDEV] TagAvailable ValueItemColumn00Ldkc1st, 11th (Index)00 - FE. Set with hexadecimal numbers in one

Página 7

Second Error CheckIn the second check, the spreadsheet settings are verified. Any errors found are displayed on theError Information list. This second

Página 8

Figure 55 Second Error Check Flow ChartThird Error CheckThe third check is performed after the Apply button is selected. Errors detected at this third

Página 9 - Configuring LUN Security

7 TroubleshootingThis chapter describes how to troubleshoot LUN Manager problems.• “Troubleshooting” (page 106)• “Calling HP Technical Support” (page

Página 10

8 Support and Other ResourcesRelated Documentation• HP StorageWorks XP24000/XP20000 Audit Log User and Reference Guide• Hitachi Cache Manager User Gui

Página 11

http://www.hp.com/support/manualsIn the Storage section, click Storage Software and then select a product.Conventions for Storage Capacity ValuesHP XP

Página 12 - Notes on Using LUN Manager

HP WebsitesFor additional information, see the following HP websites:• http://www.hp.com• http://www.hp.com/go/storage• http://www.hp.com/support/manu

Página 13 - 4 Using the LUN Manager GUI

entered from open-system hosts. When the administrator enters an RAID Manager command froman open-system host, the RAID Manager command is transferred

Página 14 - LU Path Tree

GlossaryCCHAP Challenge-Handshake authentication protocol.CU Control unit.CV, CVS Custom-sized volume, also called customized volume.DDASD Direct acce

Página 15 - LU Path List

UUUID User-definable LUN ID or logical volume ID.WWWN Worldwide Name, which is a unique identifier for a host bus adapter of a particular open-systemh

Página 16 - The WWN List

IndexAAIXfinding WWN, 33Cconventionsstorage capacity values, 108Ddocumentrelated documentation, 107documentationHP website, 107providing feedback, 109

Página 17 - LDEV List

3 Preparing for LUN Manager OperationsThis chapter describes the system requirements, instructions for configuring Remote Web Console,enabling the req

Página 18

4 Using the LUN Manager GUIThis chapter describes the windows in the LUN Manager GUI.• “LUN Manager Window” (page 13)• “Port Window” (page 19)• “Authe

Página 19 - Port Window

DescriptionItemThe WWN list is available when you select an item relatedto a Fibre Channel port from the tree. For details, see “TheWWN List” (page 16

Página 20 - Port List

When you double-click a port for which LUN security is disabled, the host groups, except for thefirst host group (host group 0), are unavailable.LU Pa

Página 21 - Change Port Mode Box

DescriptionItemSize of each logical volume.CapacityRAID level for each logical volume.If the logical volume is an external volume or a virtual volume,

Página 22

Figure 7 WWN ListThe WWN list provides information about host bus adapters that are connected to Fibre Channelports of the storage system.DescriptionI

Página 23 - Port Tree

DescriptionItemLDKC number, CU image number, and LDEV number of a logical volume.These numbers are delimited by colon (:). indicates a normal logical

Página 24 - Port Information List

The LDEV list does not contain any volume reserved by XP Auto LUN. For more information, seeHP StorageWorks XP24000/XP20000 Auto LUN Software User Gui

Página 25 - FC Switch Information List

© Copyright 2007, 2011 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or

Página 26

Figure 10 Package TreeWhen you double-click the Fibre folder, the folder opens and lists Fibre Channel adapters (CHAs).When you double-click a channel

Página 27

Figure 11 Port List Displaying Information about Fibre Channel PortsDescriptionItemPort names. For details, see “Port Serial Numbers and Port Names (4

Página 28

Figure 12 Change Port Mode Box Displaying Information about Fibre Channel PortsDescriptionItemTo change settings for a port, select the port from this

Página 29

Authentication Window, Fibre Folder SelectedWhen you launch LUN Manager and click the Authentication tab, the Authentication windowappears. This windo

Página 30 - Finding WWNs

Figure 14 Fibre FolderDescriptionIconIndicates a Fibre Channel port.Port Information ListThe Port Information list provides port information about the

Página 31 - Finding WWN for HP-UX

FC Switch Information ListFigure 16 FC Switch Information ListDescriptionColumnFibre Channel port names. For details, see “Port Serial Numbers and Por

Página 32 - Finding WWN for Solaris

Figure 17 Authentication Window (When Selecting Port Icon under Fibre Folder)DescriptionItemUse this tree to find information about user authenticatio

Página 33 - Creating Host Groups

Figure 18 Fibre FolderDescriptionIconsIndicates a Fibre Channel port.CLX-YIndicates that the host group performs authentication of hosts.host group na

Página 34

Figure 20 Authentication Information (Host) ListDescriptionColumnNames of host groups.Group NameUser names of hosts. When the user name is not defined

Página 35

5 Performing LUN Manager OperationsThis chapter provides instructions for performing LUN Manager operations.• “Launching LUN Manager for Fibre Channel

Página 36 - Table 2 Host Mode Options

Contents1 Overview of LUN Manager Operations...6Overview of LUN Manager...

Página 37

3. Group open-system hosts by host group (see “Registering Hosts in Host Groups” (page 37)).4. Associate host groups with LUs (see “Defining LU Paths

Página 38

Figure 21 LightPulse Utility/NT WindowFinding WWN for HP-UXTo find the WWN in an HP-UX environment (see “HP-UX Worldwide Name” (page 32)):1. Verify th

Página 39

Figure 22 HP-UX Worldwide NameFinding WWN for SolarisHP currently supports the JNI Fibre Channel adapter in a Sun Solaris environment. This documentwi

Página 40

Figure 23 Sun Solaris Worldwide NameFinding WWN for AIX, IRIX, or SequentTo find the WWN in an AIX, SGI Irix, or Sequent environment, use the fibre sw

Página 41 - Overview

4. Select a host mode from the Host Mode list. When selecting a host mode, you must considerthe platform and some other factors (see “Host Modes for H

Página 42

Table 1 Host Modes for Host Groups (continued)When to select this modeHost modeWhen registering Solaris server hosts in the host group09 SolarisWhen r

Página 43

Table 2 Host Mode OptionsWhen to select this optionHost mode optionsNo.When VERITAS Database Edition/Advanced Cluster for Real Application Clustersor

Página 44

Table 2 Host Mode Options (continued)When to select this optionHost mode optionsNo.When all the following conditions are satisfied:• The host mode 0C

Página 45

will be more helpful because you can name host bus adapters after the host installation site or thehost owners.NOTE:• A nickname can consist of up to

Página 46 - Switch Authentication

3. Click Apply in the LUN Manager window.A message appears and asks if you want to apply the setting to the storage system.4. Click the OK button to c

Página 47

Overview...41Host and Host Grou

Página 48

• Windows Server 2003 SP1 or later• Red Hat Enterprise Linux AS 4 Update 1 or laterIf you use other operating system than these, make sure that a logi

Página 49

This section describes the following operations on host groups, Fibre Channel ports, and FibreChannel switches for user authentication:• Settings and

Página 50

1. A host group of the storage system authenticates a host that attempts to connect (authenticationof hosts).2. The host authenticates the connection-

Página 51

(user name and secret) of the port specified on the port side matches that stored on the host, thehost allows the host group to connect.Host and Host

Página 52

If the host is not configured for authentication by host groups with CHAP, the authenticationfails and the host cannot connect to the storage system.◦

Página 53

Figure 29 Example of Authentication of HostsIn “Example of Authentication of Hosts” (page 45), host group 1 performs authentication of hosts,but host

Página 54 - Port Authentication

“Combinations of port settings and connection results” (page 46) shows the relationship betweenthe combinations of host group settings and the connect

Página 55 - Setting Port User Information

Figure 30 Flow of Authentication of Fibre Channel SwitchEach case in the flow is explained as follows. Case A to Case D in “Flow of Authentication of

Página 56

If the Fibre Channel switch of the port is not configured for authentication with CHAP,the authentication fails and the Fibre Channel switch cannot co

Página 57

and secret) specified on the port side matches that stored on the host, the host allows the hostgroup to connect.Configuring Fibre Channel Authenticat

Página 58

Configuration Definitions...93Comments...

Página 59

3. In the Port tree, select a port or host group on which you want to register user information fora host.The user information for hosts currently reg

Página 60

You should register user information for all the hosts to be connected with a host group that performsauthentication of hosts. To allow a specific hos

Página 61

1. Make sure that Remote Web Console is in Modify mode.2. Start LUN Manager and display the Authentication window (“Authentication Window (WhenSelecti

Página 62 - Deleting Host Groups

4. Right-click any point in the Authentication Information (Target) list and select SpecifyAuthentication information from the pop-up menu.The Specify

Página 63

4. Right-click any point in the Authentication Information (Target) list and select Clear Authenticationinformation from the pop-up menu.Clear Authent

Página 64

Figure 35 Set Port Information Dialog BoxSetting Port User InformationTo register user information on a Fibre Channel port:1. Make sure that Remote We

Página 65

Figure 36 Default Setting(User Name/Secret) Dialog BoxSwitch AuthenticationSetting Switch User InformationTo register user information on a Fibre Chan

Página 66

8. Click the Apply button in the Authentication window.A message appears and asks if you want to apply the setting to the storage system.9. Click the

Página 67 - Mix Mode

Figure 38 Clear Authentication Information Dialog BoxSetting the Switch Authentication ModeTo specify the authentication mode of a Fibre Channel switc

Página 68

6. Click the Apply button in the Authentication window.A message appears and asks if you want to apply the setting to the storage system.7. Click the

Página 69

1 Overview of LUN Manager OperationsThis chapter provides a very brief overview of the LUN Manager functions.• “Overview of LUN Manager” (page 6)• “Ov

Página 70

NOTE: If you check Apply this change to other ports, too and click the OK button, a dialogbox appears (“Dialog Box that Displays the Host Bus Adapters

Página 71

1. Start LUN Manager and display the LUN Manager window (“LUN Manager Window (WhenSelecting Icon under Fibre Folder)” (page 13)).2. In the tree, selec

Página 72

4. Do either of the following:• If you want to change the name of the host group, enter a new name in the Group Namebox.• If you want to change the ho

Página 73

1. Start LUN Manager and display the LUN Manager window (“LUN Manager Window (WhenSelecting Icon under Fibre Folder)” (page 13)).2. In the tree, selec

Página 74

• Specifying topology (see “Setting the Fibre Channel Topology” (page 66))• Choosing between standard mode and the high speed mode (see “ Changing the

Página 75

Table 5 Available Addresses for Fibre Channel Ports (continued)LoopIDPortAddress(AL-PA)LoopIDPortAddress(AL-PA)LoopIDPortAddress(AL-PA)LoopIDPortAddre

Página 76

1. Start LUN Manager and display the Port window (“Port Window (When Selecting Icon underFibre Folder)” (page 19)).2. In the Package tree, select the

Página 77

If a fabric switch is used, specify FC-AL or point-to-point in the LUN Manager window (by default,FC-AL is specified). If a fabric switch is used, con

Página 78

You must apply High Speed mode or Initiator/External MIX mode to groups of four ports, not toindividual ports. In LUN Manager terminology, each group

Página 79

Figure 43 Ports in High Speed Mode or Initiator/External MIX modeIf High Speed mode is applied to the four ports in a port block, only two of the port

Página 80 - Deleting LU Paths

2 About LUN Manager OperationsThis chapter provides an introduction to Fibre Channel operations, LUN Security, and HPStorageWorks RAID Manager.• “Over

Página 81

To improve the I/O processing speed by applying High Speed mode, a path definition is alsonecessary for a port that cannot be used for the connection

Página 82

Table 6 Port Serial Numbers and Port Names (4-port Fibre Channel Adapter) (continued)High Speed mode orInitiator/ExternalMIX modeStandard modePort ser

Página 83 - Using LUN Security

High Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberHigh Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumber--

Página 84 - Disabling LUN Security

High Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberHigh Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumber--

Página 85 - Deleting Command Devices

High Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberHigh Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberCL

Página 86 - Setting UUID

Table 7 Port Serial Numbers and Port Names (8-port Fibre Channel Adapter) (continued)High Speed mode orInitiator/ExternalMIX modeStandard modePort ser

Página 87

High Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberHigh Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberCL

Página 88 - Clearing the setting of UUID

High Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberHigh Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberCL

Página 89 - File Loader

High Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberHigh Speed mode orInitiator/ExternalMIX modeStandard modePort serialnumberCL

Página 90 - Spreadsheet File Requirements

Table 8 Port Serial Numbers and Port Names (HP StorageWorks XP20000 Disk Array)(continued)High Speed mode,Initiator/ExternalMIX modeStandard modePort

Página 91 - Spreadsheet Components

A host group can only contain hosts that are connected to the same port, and cannot contain hoststhat are connected to different ports. For example, i

Página 92 - Function Tags

To view a list of concatenated parity groups:1. Start LUN Manager and display the LUN Manager window (“LUN Manager Window (WhenSelecting Icon under Fi

Página 93 - Configuration Definitions

Figure 45 Information about LU Paths to be DeletedNOTE: If you delete numerous paths at one time, the deletion may take time and the dialog boxmay see

Página 94

NOTE: You cannot paste paths to initiator ports.To copy one or more (but not all) LU paths defied to a host group, take the following steps:a. Select

Página 95 - Column Format

Figure 46 Alternate Paths Dialog BoxNOTE: The Group ID column indicates group numbers (G-IDs) of the host group.Using LUN SecurityTo protect mission-c

Página 96 - Setting the CHA Mode

7. Click the Apply button in the LUN Manager window.A message appears and asks if you want to apply the setting to the storage system.8. Click the OK

Página 97 - Port Settings

1. Start LUN Manager and display the LUN Manager window (“LUN Manager Window (WhenSelecting Icon under Fibre Folder)” (page 13)).2. In the upper-right

Página 98 - Setting the Host Group

3. Select Cmd. Dev. Security: Disable -> Enable from the pop-up menu.A message appears asking if you want to apply command device security.4. Click

Página 99

(page 88)), enter a UUID in the UUID box. If a UUID is already specified in the UUID box,you can change it. However, if multiple LUNs, or N/As are sel

Página 100 - Setting the WWN Information

Figure 48 Set UUID Window (When a Server Host Other Than OpenVMS is Used)NOTE: When the host mode 05 OpenVMS is used, the disk storage system version

Página 101 - Setting the LU Path

6 Performing LUN Manager Operations Using ConfigurationFile LoaderThis chapter provides instructions for performing LUN Manager operations using Confi

Página 102

You can add, change, and delete LU paths when the system is in operation. For example, if newdisks or server hosts are added to your storage system, y

Página 103 - Error Check

Figure 49 Configuration File Loader Operation Flow ChartThis chapter provides an overview of LUN Manager spreadsheets that are required for settingsus

Página 104 - Second Error Check

Figure 50 Sample SpreadsheetAll of the formatting requirements in “Spreadsheet File Formatting Requirements” (page 91) mustbe satisfied.Table 10 Sprea

Página 105 - Third Error Check

Spreadsheet DeclarationThe spreadsheet declaration is required, and is written at the beginning of the spreadsheet. Certainparts of the declaration wi

Página 106 - 7 Troubleshooting

• The row after the function tag indicates the required setting items (Cha and PcbMode in theexample) for the function. The setting items are separate

Página 107 - 8 Support and Other Resources

parameters (adding, deleting, or changing) for the storage system. A row of configuration definitionscan be divided into the current settings area, a

Página 108 - HP Technical Support

CommentsYou can also type comment rows in the spreadsheet by beginning a row with the # character. Thecomment row can consist of any characters in any

Página 109 - Documentation Feedback

Table 12 LUN Manager Spreadsheet FormatFunction Tag[LDEV][LUN][WWN][HostGroup][Port][Cha]ColumnLdkcPortPortPortPortCha1stCuGroup IdGroup IdGroup IdSec

Página 110 - Glossary

Table 13 Available Configuration Values for the [CHA] TagAvailable ValuesItemColumnOne of the following can be set:CHA-1AL,CHA-1AU,CHA-1BL,CHA-1BU,CHA

Página 111

Table 14 Available [Port] Tag Configuration ValuesAvailable ValueItemColumnSet one of the following (Maximum number of ports is 256):1A, 1B, 1C, 1D, 1

Página 112 - 112 Index

Table 15 Available Configuration Values for the [HostGroup] TagAvailable ValuesItemColumnOne of the following can be set (Maximum number of ports is 2

Comentários a estes Manuais