332 Status Conditions and Sense Code Information
2F 00 Commands Cleared by Another Initiator
The controller received a Clear Queue message from another
initiator. This error is to notify the current initiator that the con-
troller cleared the current initiators commands if it had any out-
standing.
31 01 Format Command Failed
A Format Unit command issued to a drive returned an unrecov-
erable error.
32 00 Out of Alternates
A Re-assign Blocks command to a d rive failed.
3F 01 Drive micro-code changed
3F 0E Reported LUN’s data has changed.
Previously LUN data reported via a Report LUNs command has
changed (due to LUN creation/deletion or controller hot swap)
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation