Figure 12 T
he Port-LUN tab of the Auto LUN Window
When the Po
rt-LUN tab is active, the Auto LUN window contains the following items:
When Monitoring Switch is Enable, Performance Monitor is monitoring the storage system (a
Disable setting indicates that the system is not being monitored).
Gatherin
gInterval indicates that the statistics are collected at the interval displayed here. If the
number of
the CUs to be monitored are 64 or less, the value between 1 and 15 appears as a
gathering interval by minutes. For example, if 1min. is displayed, the information obtained every
one minute are displayed in the list and the graph. In case 65 or more CUs are monitored, the
statist
ics are displayed every 5, 10 or 15 minutes.
Thedrop-down list on theright of Monitoring Data indicates storing period of statistics (monitoring
data). The statistics displayed in the Port-LUN tab are stored only in short range. The range of
monitoring data that can be displayed in the window is between 8 hours and 15 days depending
on the g
athering interval.
For det
ails on the types of storing period of statistics, see
Understanding Statistical Storage Ranges”onpage15.
For details on the relationship between collection interval and the storing period of the statistics,
see Monitoring Options Windowon page 42.
Monit
oring Term let you narrow the range of statistics that should be displayed in the window.
The st
arting and ending time for collecting statistics are displayed on both sides of the slide bar.
Perfo
rmance Monitor stores the monitoring data between these times, and you can specify desired
term
within this range as the target of display in lists and graphs.
For e
xample, if you want to view statistics within the range of 10:30 July 1 2007 to 10:30 July
22007, youset 2007/07/01 10:30 to the From box, set 2007/07/02 10:30 to the To
box, and then click the Apply button.
To se
t a date and time to the From and To boxes, do either of the following:
Movethe slider to theleftorto the right.
In the text box, select the number that you want to change. Next, click the upward or
down
ward arrow button.
When you specify dates and time in From and To boxes, Performance Monitor calculates the
length (in minutes) of the specied period and displays the calculated length. When calculating
the length in minutes, Performance Monitor rounds up the fraction.
Note:
The From and To boxes are grayed out if the monitoring data (that is, obtained statistics)
is n
ot stored in the storage system.