Hp XP RAID Manager Software Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Armazenamento Hp XP RAID Manager Software. HP XP RAID Manager Software User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
HP XP P9000 RAID Manager Installation
and Configuration Guide
Abstract
This guide describes and provides instructions to install and configure HP XP P9000 RAID Manager Software on HP XP P9500
disk arrays. The intended audience is a storage system administrator or authorized service provider with independent knowledge
of HP XP P9000 disk arrays and the HP Remote Web Console.
HP Part Number: T1610-96062
Published: January 2014
Edition: Tenth
Vista de página 0
1 2 3 4 5 6 ... 94 95

Resumo do Conteúdo

Página 1 - Abstract

HP XP P9000 RAID Manager Installationand Configuration GuideAbstractThis guide describes and provides instructions to install and configure HP XP P900

Página 2

Supported Snapshot environmentsTable 5 Supported platforms for SnapshotI/O InterfaceVolume ManagerFailover SoftwareOperating SystemVendorFibreVxVM–Sol

Página 3 - Contents

Table 6 Supported Platforms for Data Retention (continued)I/O InterfaceVolume ManagerOperating SystemVendorSCSI/Fibre2–Red Hat Linux6.0/7.0/AS2.1, 3.0

Página 4 - 4 Contents

Supported guest OS for VMTable 8I/O interfaceVolume mappingRAID Manager supportconfirmationGuest OSLayerVM Vendor--ConfirmedWindows 2008 R2GuestVMware

Página 5 - 1 Installation requirements

Table 10 Supported Platforms: IPv4 vs IPv6RAID Manager / IPv6IPv4OpenVMSTru64LinuxWindowsAIXSolarisHP-UXN/AAVAVN/AAVAVAVHP-UXRAIDManager/ IPv4N/AAVAVN

Página 6 - 6 Installation requirements

Figure 1 Example of a RAID Manager configuration on z/LinuxThe restrictions for using RAID Manager with z/Linux are:• Command device. RAID Manager use

Página 7 - Supported environments

The following commands cannot be used because there is no PORT information:• raidscan -pd <device>, raidar -pd <device>, raidvchkscan -pd

Página 8

6. About running on SVC. The ESX Server 3.0 SVC (service console) is a limited distribution ofLinux based on Red Hat Enterprise Linux 3, Update 6 (RHE

Página 9

hdisk2 -> NOT supported INQ. [AIX ] [VDASD ]::hdisk19 -> NOT supported INQ. [AIX ] [VDASD

Página 10

3. Lun sharing between guest OS and console OS. It is not possible to share a command deviceas well as a normal Lun between a guest OS and a console O

Página 11

For Windows systems: Ws2_32.dllFor HP-UX (PA/IA) systems: /usr/lib/libc.slHowever, RAID Manager may need to specify a different PATH to use the librar

Página 12 - Supported guest OS for VM

© Copyright 2010, 2014 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or

Página 13

where Device:[directory] is defined as SYS$POSIX_ROOT(3) IPC method using MailBox driverAs an alternate method of the UNIX domain socket for IPC (Inte

Página 14

$$ horcmshutdown 0 1inst 0:HORCM Shutdown inst 0 !!!inst 1:HORCM Shutdown inst 1 !!!$(5) Command deviceRAID Manager uses the SCSI class driver for acc

Página 15

• -CLI or -CLIWP or -CLIWN or -CM for the inqraid options• Environmental variable name such as HORCMINST … controlled by CRTLAlso you need to define t

Página 16 - Restrictions on AIX VIO

$ PRODUCT INSTALL RM /source=Device:[directory]/LOG - _$ /destination=SYS$POSIX_ROOT:[000000]Device:[directory] where HITACHI-ARMVMS-RM-V0122-2-1.PC

Página 17

After making the S-VOL for Writing enable by using “pairsplit” or “horctakeover” command, youneed to perform the “mcr sysman” command in order to use

Página 18 - Environment variable

(5) Verify a physical mapping of the logical device.$ HORCMINST := 0$ raidscan -pi DKA145-151 -findDEVICE_FILE UID S/F PORT TARG LUN SE

Página 19 - Porting notice for OpenVMS

Command examples in DCL(1) Setting the environment variable by using Symbol.$ HORCMINST := 0$ HORCC_MRCF := 1$ raidqry -lNo Group Hostname

Página 20 - 20 Installation requirements

DKA146 URA URA_000 CL1-H 0 2 0 30009 146DKA147 URA URA_001 CL1-H 0 3 0 30009

Página 21 - (8) Startup log files

$1$DGA148 0 F CL2-H 0 4 30009 148 OPEN-9$ pairdisplay -g BCVG -fdcGroup PairVol(L/R) Device_File M ,Seq#,LDEV#..P/S

Página 22 - (12) Installation

(5) Verify a physical mapping of the logical device.bash$ export HORCMINST=0bash$ raidscan -pi DKA145-151 -findDEVICE_FILE UID S/F PORT TAR

Página 23 - Known issues

Contents1 Installation requirements...5System requirements...

Página 24 - 24 Installation requirements

Using RAID Manager with Hitachi and other storage systemsTable 11 (page 30) shows the related two controls between RAID Manager and the RAID storagesy

Página 25 - Porting notice for OpenVMS 25

Figure 6 Relationship between application, CCI, and storage systemUsing RAID Manager with Hitachi and other storage systems 31

Página 26 - Command examples in DCL

2 Installing and configuring RAID ManagerThis chapter describes and provides instructions for installing and configuring RAID Manager.Installing the R

Página 27

to UNIX commands that may be different on your platform. Please consult your operating systemdocumentation (for example, UNIX man pages) for platform-

Página 28 - Startup procedures in bash

1. Change the owner of the following RAID Manager files from the root user to the desired username:• /HORCM/etc/horcmgr• All RAID Manager commands in

Página 29 - Porting notice for OpenVMS 29

Windows installationMake sure to install RAID Manager on all servers involved in RAID Manager operations. If network(TCP/IP) is not established, insta

Página 30

Because the ACL (Access Control List) of the Device Objects is set every time Windows starts-up,the Device Objects are also required when Windows star

Página 31

2. Execute the following command:$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG -_$ /destination=SYS$POSIX_ROOT:[000000] Devic

Página 32 - UNIX installation

Setting up UDP portsThis section contains information that may be of assistance in setting up strict firewalls.If you do not have a HORCM_MON IP addre

Página 33

6. To set an alternate command device, repeat this procedure for another volume. For informationabout alternate command devices, see “About alternate

Página 34

5 Troubleshooting...47Troubleshooting...

Página 35 - Windows installation

available, all commands terminate abnormally, and the host cannot issue RAID Manager commandsto the storage system. To ensure that RAID Manager operat

Página 36 - OpenVMS installation

characteristics. And the RAID storage system determines whether it is a Fast Snap pair or a Snapshotpair based on the type of the pool to be used.Ther

Página 37 - Usage: raidqry [options]

Do not edit the configuration definition file while RAID Manager is running. Shut down RAIDManager, edit the configuration file as needed, and then re

Página 38 - Setting the command device

3 Upgrading RAID ManagerFor upgrading RAID Manager software, the RMuninst script on the CD-ROM is used.For other media, please use the instructions in

Página 39 - Setting the command device 39

6. Execute Setup.exe (\program\RM\WIN_NT\RMXP\Setup.exe or\program\RM\WIN_NT\RMXP_X64\Setup.exe on the CD) and follow the instruction on thescreen to

Página 40

4 Removing RAID ManagerThis chapter explains how to remove RAID Manager.Removing RAID Manager in a UNIX environmentTo remove the RAID Manager software

Página 41

2. You can remove the RAID Manager software only when RAID Manager is not running. If RAIDManager software is running, shut down RAID Manager using th

Página 42

5 TroubleshootingThis chapter provides troubleshooting information.TroubleshootingIf you have a problem installing or upgrading the RAID Manager softw

Página 43 - 3 Upgrading RAID Manager

6 Support and other resourcesContacting HPFor worldwide technical support information, see the HP support website:http://www.hp.com/supportBefore cont

Página 44 - 44 Upgrading RAID Manager

HP websitesFor additional information, see the following HP websites:• http://www.hp.com• http://www.hp.com/go/storage• http://www.hp.com/service_loca

Página 45 - 4 Removing RAID Manager

1 Installation requirementsThis chapter describes the installation requirements for the RAID Manager (RAID Manager) software.System requirementsRAID M

Página 46 - 46 Removing RAID Manager

Table 13 Document conventions (continued)ElementConventionMonospace text• File and directory names• System output• Code• Commands, their arguments, a

Página 47 - 5 Troubleshooting

A Fibre-to-SCSI address conversionDisks connected with Fibre Channel display as SCSI disks on UNIX hosts. Disks connected withFibre Channel connection

Página 48 - 6 Support and other resources

Example 6 Using Raidscan to display TID and LUN for Fibre Channel devicesC:\>raidscan -pd hd6 -x drivescan hd6Harddisk 6... Port[ 2] PhId[ 4] TId[

Página 49 - Typographic conventions

Figure 10 LUN configurationRAID Manager uses absolute LUNs to scan a port, whereas the LUNs on a group are mapped forthe host system so that the targe

Página 50

The conversion table for Windows systems is based on the Emulex driver. If a different FibreChannel adapter is used, the target ID indicated by the ra

Página 51 - LUNTIDLUNTIDLUNTIDPort

Table 16 Fibre address conversion table for Solaris and IRIX systems (Table1) (continued)C7C6C5C4C3C2C1C0TIDAL-PATIDAL-PATIDAL-PATIDAL-PATIDAL-PATIDAL

Página 52

B Sample configuration definition filesThis chapter describes sample configuration definition files for typical RAID Manager configurations.Sample con

Página 53

Example 9 Configuration File Example – UNIX-Based ServersHORCM_MON#ip_address service poll(10ms) timeout(10ms)HST1 horcm 1000

Página 54

• Poll: Specifies the interval for monitoring paired volumes in increments of 10 ms. To reducethe HORCM daemon load, make this interval longer. If set

Página 55

HORCM_CMD#dev_name dev_name dev_name \\.\CMD-30095-250-CL1-ATo allow more flexibility, RAID Manager allows the followi

Página 56

the description of the configuration file.It is necessity (Number of units ID×200 KB + Numberof LDEV×360B + Number of the entry×180B) in the minimum◦

Página 57 - (1) HORCM_MON

Example for minimum specification. Specifies to use any command device for Serial#30095:\\.\CMD-30095:/dev/rdsk/Example for under Multi Path Driver. S

Página 58 - (2) HORCM_CMD

The following ports can only be specified for XP12000 Disk Array/XP10000 Disk Array andXP24000/XP20000 Disk Array:OptionOptionOptionBasic-rnqnpnnnmnln

Página 59

• MU# for Continuous Access Synchronous/Continuous Access Journal: Defines the mirror unitnumber (0 - 3) if using redundant mirror for the identical L

Página 60 - (3) HORCM_DEV

For example:# horcctl -ND -g IP46GCurrent network address = 158.214.135.106,services = 50060# horcctl -NC -g IP46GChanged network address(158.214.135.

Página 61

In the case of mixed IPv4 and IPv6, it is possible to communicate between HORCM/IPv4 andHORCM/IPv6 and HORCM/IPv6 using IPv4 mapped to IPv6 and native

Página 62 - (4) HORCM_INST

oradb dev1 30095 02:40 0oradb dev2 30095 02:41 0• Specifying "CU:LDEV" in

Página 63 - # horcctl -ND -g IP46G

Examples of RAID Manager configurationsThe following examples show RAID Manager configurations, the configuration definition file(s) foreach configura

Página 64 - (5) HORCM_LDEV

Example of RAID Manager commands with HOSTA:• Designate a group name (Oradb) and a local host P-VOL a case.# paircreate -g Oradb -f never -vlThis c

Página 65 - (8)HORCM_ALLOW_INST

This command creates pairs for all LU designated as Oradb in the configuration definition file (twopairs for the configuration in the above figure).•

Página 66

Figure 19 Continuous Access Synchronous Local Configuration Example[Note 1] : Input the raw device (charactor device) name of UNIX/Windows system for

Página 67 - # pairdisplay -g Oradb

Supported environmentsThis section specifies the supported operating systems, failover software, and I/O interfaces fordata management operations usin

Página 68

Example of RAID Manager commands with HOSTA:• Designate a group name (Oradb) and a local host P- VOL a case.# paircreate -g Oradb -f never -vlThis

Página 69

If this restriction is exceeded, then use a different SCSI path for each instance. For example, thecommand devices for the following figure would be:•

Página 70

Figure 20 Continuous Access Synchronous Configuration Example for Two InstancesLegend[Note 1] : it describes raw device (charactor device) name of UNI

Página 71

For Windows: set HORCMINST=0• Designate a group name (Oradb) and a local instance P- VOL a case.# paircreate -g Oradb -f never -vlThis command crea

Página 72

This command creates pairs for all LU designated as Oradb in the configuration definition file (twopairs for the configuration in above figure).• Desi

Página 73

Figure 21 Business Copy Configuration Example (continues on the next page)Examples of RAID Manager configurations 75

Página 74 - # pairdisplay -g Oradb

Figure 22 Business Copy Configuration Example (continued)Legend[Note 1] : it describes raw device (charactor device) name of UNIX/Windows system forco

Página 75

Windows: set HORCC_MRCF=1• Designate a group name (Oradb) and a local host P-VOL a case.# paircreate -g Oradb -vlThis command creates pairs for all L

Página 76

For Windows: set HORCC_MRCF=1• Designate a group name (Oradb1) and a local host P-VOL a case.# paircreate -g Oradb1 -vlThis command creates pairs for

Página 77

For Windows: set HORCC_MRCF=1• Designate a group name (Oradb2) and a local host P-VOL a case.# paircreate -g Oradb2 -vlThis command creates pairs for

Página 78

Table 2 Supported platforms for Continuous Access Synchronous (continued)I/O InterfaceVolume ManagerFailover SoftwareOperating SystemVendorFibreLVM, S

Página 79 - # paircreate -g Oradb2 -vr

If this restriction is exceeded, then use a different SCSI path for each instance. For example, thecommand devices for the following figure would be:•

Página 80

Figure 23 Business Copy Configuration Example with Cascade PairsLegend[Note 1] : it describes raw device (charactor device) name of UNIX/Windows syste

Página 81

For Windows:set HORCMINST=0 set HORCC_MRCF=1• Designate a group name (Oradb) and a local instance P- VOL a case.# paircreate -g Oradb -vl# paircreat

Página 82 - # paircreate -g Oradb1 -vl

If this restriction is exceeded, then use a different SCSI path for each instance. For example, thecommand devices for the following figures would be:

Página 83

Figure 24 Cnt Ac-S/BC Configuration Example with Cascade PairsExample of RAID Manager commands with HOSTA and HOSTB:• Designate a group name (Oradb) o

Página 84

These commands create pairs for all LUs assigned to groups Oradb and Oradb1 in the configurationdefinition file (four pairs for the configuration in t

Página 85

# pairdisplay -g oradb1 -m casGroup PairVol(L/R) (Port#,TID,LU-M),Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# Moradb1 oradev11(L) (CL1-D , 2, 1-0)30053 2

Página 86

Correspondence of the configuration file and mirror descriptorsThe group name and MU# which are described in HORCM_DEV of a configuration definition f

Página 87

topics present examples of Business Copy and Business Copy/ Continuous Access Synchronouscascading configurations.Business CopyThe following figure sh

Página 88 - Business Copy

Figure 28 Pairdisplay -g on HORCMINST1Figure 29 Pairdisplay -d on HORCMINST0Cascading connections for Continuous Access Synchronous and Business CopyT

Página 89

Table 3 Supported platforms for Continuous Access Asynchronous (continued)I/O InterfaceVolume ManagerFailover SoftwareOperating SystemVendorFibreLDMMS

Página 90

Figure 30 Cnt Ac-S/BC Cascading Connection and Configuration FileThe following figures cascading configurations and the pairdisplay information for ea

Página 91

Figure 32 Pairdisplay for Continuous Access Synchronous on HOST2 (HORCMINST)Figure 33 Pairdisplay for Business Copy on HOST2 (HORCMINST)Figure 34 Pair

Página 92 - Glossary

GlossaryAL-PA Arbitrated loop physical address. A 1-byte value that the arbitrated loop topology uses to identifythe loop ports. This value becomes th

Página 93

LUSE Logical Unit Size Expansion. The LUSE feature is available when the HP StorageWorks LUNManager product is installed, and allows a LUN, normally a

Página 94 - 94 Index

IndexAaccess requirements, 5AIX VIO, restrictions, 16alternate command devices, 39Ccascading, configuration definitions, 86changing the userUNIX envir

Página 95

IIn-Band command execution, 37installing hardware, 32installing software, 32OpenVMS environment, 36UNIX environment, 32Windows environment, 35interact

Modelos relacionados XP P9500 Storage

Comentários a estes Manuais

Sem comentários