Microsoft Windows Event ID and SNMP Traps Reference Guide For use with SmartStart version 8.25 Part number: 347870-009 Ninth edition: June 2009

Página 2

Foundation agents 10 • cpqMeAlarmVariable • cpqMeAlarmSampleType • cpqMeAlarmValue • cpqMeAlarmRisingThreshold • cpqMeAlarmOwner • cpqMeAl

Página 3 - Contents

Server agents 100 Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeFltTolFanChassis Supporting SNMP Trap Description: “The Fans a

Página 4 - Introduction

Server agents 101 • cpqHoTrapFlags • cpqHeTemperatureChassis • cpqHeTemperatureLocale Supporting SNMP Trap Description: “Temperature Exceeded

Página 5 - Telephone numbers

Server agents 102 Symptom: The DC-DC Power Converter condition has been set to degraded for the specified chassis, slot, and socket. Supporting

Página 6 - Foundation agents

Server agents 103 Log Message: Hot Plug PCI Board Removed. A hot plug PCI adapter has been removed from the system. SNMP Trap: cpqSiHotPlugSlotB

Página 7 - Foundation agents 7

Server agents 104 • cpqSiHotPlugSlotIndex • cpqSiHotPlugSlotErrorStatus Supporting SNMP Trap Description: “Hot Plug Slot Board Failed in Chass

Página 8 - Foundation agents 8

Server agents 105 Supporting SNMP Trap Description: “The enclosure name has changed to [cpqRackCommonEnclosureName] in rack [cpqRackName].” NT E

Página 9 - Event Identifiers 1105-1808

Server agents 106 Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] has been inserted into rack [cpqRackName].” NT E

Página 10 - Foundation agents 10

Server agents 107 • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTempLocation • cpqRackCommonEnclosureSparePartNumber • cpqRackCo

Página 11 - Foundation agents 11

Server agents 108 • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureFanLocation • cpqRack

Página 12 - Foundation agents 12

Server agents 109 • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackComm

Página 13 - Foundation agents 13

Foundation agents 11 • cpqMeAlarmRisingThreshold • cpqMeAlarmOwner • cpqMeAlarmSeverity • cpqMeAlarmExtendedDescription Supporting SNMP Trap

Página 14 - Foundation agents 14

Server agents 110 • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureFanLoca

Página 15 - Foundation agents 15

Server agents 111 Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackPowerSupplyEnclosureName • cpq

Página 16 - Foundation agents 16

Server agents 112 SNMP Trap: cpqRackPowerSupplyRemoved - 22016 in CPQRACK.MIB Symptom: The power supply has been removed. User Action: None. Sup

Página 17 - Event Identifiers 2048-2359

Server agents 113 Event Title: Rack Power Subsystem Not Redundant Log Message: The rack power subsystem is no longer in a redundant state. SNMP

Página 18 - Foundation agents 18

Server agents 114 Log Severity: Warning (2) Event Title: Rack Power Subsystem Overload Log Message: The rack power subsystem overload condition.

Página 19 - Foundation agents 19

Server agents 115 Log Severity: Error (3) Event Title: Server Power On Prevented Log Message: Server power on prevented to preserve redundancy.

Página 20 - Foundation agents 20

Server agents 116 NT Event ID: 1166 (Hex)0xc435048e (cpqsvmsg.dll) Log Severity: Error (3) Event Title: Inadequate Power To Power On Log Message

Página 21 - Event Identifiers 3072-3876

Server agents 117 • cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: “Inadequate power to power on blade [cpqRackServerB

Página 22 - Foundation agents 22

Server agents 118 • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: “Fuse open fuse

Página 23 - Foundation agents 23

Server agents 119 • cpqRackServerBladePosition • cpqRackServerBladeSparePartNumber • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosur

Página 24 - Foundation agents 24

Foundation agents 12 Symptom: This trap is sent any time the condition of a cluster resource becomes degraded. User Action: Make a note of the c

Página 25 - Event Identifiers 4352-4626

Server agents 120 • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureSparePartNumber • cpq

Página 26

Server agents 121 • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: “Unknown power c

Página 27 - Foundation agents 27

Server agents 122 Supporting SNMP Trap Description: “Power subsystem has too may power enclosures [cpqRackCommonEnclosureName], in rack [cpqRack

Página 28 - Foundation agents 28

Server agents 123 User action: None Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: “The Management pr

Página 29 - Storage agents

Server agents 124 • sysName • cpqHoTrapFlags • cpqSeUSBDeviceType • cpqSeUSBDeviceName Supporting SNMP Trap Description: This trap is sent w

Página 30 - Storage agents 30

Server agents 125 Log Severity: Warning (2) Log Message: The %1 Agent is older than other components. The %1 Agent is older than the other compo

Página 31 - Storage agents 31

Server agents 126 Event identifier: cpqsvmsg.dll - 3332 (Hex)0x84350d04 (Service Event) Log Severity: Warning (2) Log Message: Could not read th

Página 32 - Event Identifiers 1061-1098

Server agents 127 Log Severity: Warning (2) Log Message: “%1”. The data contains the error code. Event identifier: cpqsvmsg.dll - 5636 (Hex)0x84

Página 33 - Storage agents 33

Server agents 128 Event identifier: cpqsvmsg.dll - 5645 (Hex)0x8435160d (Service Event) Log Severity: Warning (2) Log Message: The Rack And Encl

Página 34 - Storage agents 34

NIC agents 129 NIC agents Event Identifiers 256-299 Event identifier: cpqnimsg.dll - 256 (Hex)0x84350100 (Service Event) Log Severity: Warning (

Página 35 - Storage agents 35

Foundation agents 13 Symptom: This trap is sent any time the condition of a cluster network has failed. User Action: Make a note of the cluster

Página 36 - Storage agents 36

NIC agents 130 Event identifier: cpqnimsg.dll - 264 (Hex)0x84350108 (Service Event) Log Severity: Warning (2) Log Message: Unable to open the re

Página 37 - Storage agents 37

NIC agents 131 Log Severity: Warning (2) Log Message: There were no physical adapters in team: “%1.” This error can be caused by improperly inst

Página 38 - Event Identifiers 1101-1199

NIC agents 132 Log Severity: Warning (2) Log Message: The NIC Agent service could not load the module “%1”. The data contain the error code. Eve

Página 39 - Storage agents 39

NIC agents 133 Cause: WMI service is probably not running. Starting WMI service or NIC agent might solve this problem. Event identifier: cpqnims

Página 40 - Storage agents 40

NIC agents 134 Log Message: The NIC SNMP Management Agent was unable to process a SNMP request because the Insight Agents Service is not up and

Página 41 - Storage agents 41

NIC agents 135 Log Message: The NIC SNMP Management Agent has determined the Insight Agent Management service is running. Event identifier: cpqn

Página 42 - Storage agents 42

NIC agents 136 • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqNicIfLogMapAdapterOKCount Supporting SNMP Trap Desc

Página 43 - Storage agents 43

NIC agents 137 • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqSiServerSystemId • cpqNicIfPhysAdapterStatus • cp

Página 44 - Storage agents 44

NIC agents 138 Symptom: This trap is sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least o

Página 45 - Storage agents 45

Foundation agents 14 Symptom: The Processor Time performance property is set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlag

Página 46 - Storage agents 46

Foundation agents 15 Log Message: The Cache Performance Instance, '%4' is failed with Cache Copy Read Hits of %5 percent. SNMP Trap: c

Página 47 - Storage agents 47

Foundation agents 16 Supporting SNMP Trap Description: “The PagingFile performance instance, [cpqOsPagingFileInstance] is critical with PagingFi

Página 48 - Storage agents 48

Foundation agents 17 • cpqHoTrapFlags • cpqHoCriticalSoftwareUpdateData Supporting SNMP Trap Description: “[cpqHoCriticalSoftwareUpdateData]”

Página 49 - Storage agents 49

Foundation agents 18 Log Severity: Warning (2) Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the syst

Página 50 - Storage agents 50

Foundation agents 19 Log Message: Unable to acquire the current process list. This error can be caused by a low memory condition. Rebooting the

Página 51 - Storage agents 51

Legal notices © Copyright 2003, 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without noti

Página 52 - Storage agents 52

Foundation agents 20 Log Message: The Threshold Agent could not create its main thread of execution. The data contains the error code. Event ide

Página 53 - Storage agents 53

Foundation agents 21 Log Message: The Threshold Agent could not set the variable because the value is invalid or out of range. The data contains

Página 54 - Storage agents 54

Foundation agents 22 Event identifier: cpqhsmsg.dll - 3086 (Hex)0x84350c0e (Service Event) Log Severity: Warning (2) Log Message: Unable to load

Página 55 - Storage agents 55

Foundation agents 23 Log Severity: Warning (2) Log Message: Could not enumerate all of the nodes in the cluster. The data contains the error cod

Página 56 - Storage agents 56

Foundation agents 24 Log Message: Resource status is online pending. The resource is being put back online. Event identifier: cpqhsmsg.dll - 386

Página 57 - Storage agents 57

Foundation agents 25 Log Message: Could not enumerate the cluster's networks. The Cluster service may not be running. Try to restart the Cl

Página 58 - Storage agents 58

Foundation agents 26 Event identifier: cpqhsmsg.dll - 4361 (Hex)0x84351109 (Service Event) Log Severity: Warning (2) Log Message: The External S

Página 59 - Storage agents 59

Foundation agents 27 Event identifier: cpqhsmsg.dll - 4407 (Hex)0x84351137 (Service Event) Log Severity: Warning (2) Log Message: The External S

Página 60 - Storage agents 60

Foundation agents 28 Log Message: The Agent failed to initialize WMI. WMI service may not have started or may still be in the starting state. Ev

Página 61 - Storage agents 61

Storage agents 29 Storage agents Event Identifiers 256-774 Event identifier: cpqstmsg.dll - 256 (Hex)0x84350100 (Service Event) Log Severity: Wa

Página 62 - Storage agents 62

Contents 3 Contents Introduction ...

Página 63 - Storage agents 63

Storage agents 30 Event identifier: cpqstmsg.dll - 264 (Hex)0x84350108 (Service Event) Log Severity: Warning (2) Log Message: The Storage Agents

Página 64 - Event Identifiers 1200-1294

Storage agents 31 Log Message: The Storage Agents service encountered a fatal error. The service is terminating. The data contains the error cod

Página 65 - Storage agents 65

Storage agents 32 Log Message: The Drive Array Agent storage system table is full. Event identifier: cpqstmsg.dll - 574 (Hex)0x8435023e (Service

Página 66 - Storage agents 66

Storage agents 33 User Action: Replace the physical drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaPhyDrvCntlrIndex • c

Página 67 - Storage agents 67

Storage agents 34 • cpqDaSpareBay Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].” NT Event ID: 1064 (Hex)0xc4350428

Página 68 - Storage agents 68

Storage agents 35 • cpqDaAccelSerialNumber • cpqDaAccelTotalMemory • cpqDaAccelStatus • cpqDaAccelErrCode Supporting SNMP Trap Description:

Página 69 - Storage agents 69

Storage agents 36 Supporting SNMP Trap Description: “Battery status is failed.” NT Event ID: 1068 (Hex)0xc435042c (cpqstmsg.dll) Log Severity: E

Página 70 - Storage agents 70

Storage agents 37 • sysName • cpqHoTrapFlags • cpqScsiPhyDrvStatus • cpqScsiPhyDrvCntlrIndex • cpqScsiPhyDrvBusIndex • cpqScsiPhyDrvIndex

Página 71 - Storage agents 71

Storage agents 38 Supporting SNMP Trap Description: “Storage System will be shut down.” NT Event ID: 1077 (Hex)0x84350435 (cpqstmsg.dll) Log Sev

Página 72 - Storage agents 72

Storage agents 39 Log Severity: Warning (2) Event Title: Storage System Side Panel Removed. Log Message: The side panel has been removed on the

Página 73 - Storage agents 73

Introduction 4 Introduction This document contains a listing of the Microsoft® Windows Server® 2003 Event Log messages associated with SNMP traps

Página 74 - Storage agents 74

Storage agents 40 • cpqHoTrapFlags • cpqSsBoxFltTolPwrSupplyStatus Supporting SNMP Trap Description: “A storage system power supply unit has b

Página 75 - Storage agents 75

Storage agents 41 Symptom: Tape Drive Cleaning Tape Needs Replacing. The Insight Agent has detected that an autoloader tape unit has a cleaning

Página 76 - Storage agents 76

Storage agents 42 NT Event ID: 1145 (Hex)0xc4350479 (cpqstmsg.dll) Log Severity: Error (3) Event Title: External Array Logical Drive Status Chan

Página 77 - Event Identifiers 1343-4613

Storage agents 43 • cpqFcaPhyDrvModel • cpqFcaPhyDrvSerialNum • cpqFcaPhyDrvFWRev • cpqFcaPhyDrvFailureCode Supporting SNMP Trap Description

Página 78 - Storage agents 78

Storage agents 44 • cpqSsChassisName • cpqSsChassisTime • cpqFcaAccelBoxIoSlot • cpqFcaAccelStatus • cpqFcaCntlrModel • cpqFcaAccelSerialN

Página 79 - Storage agents 79

Storage agents 45 • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqFcaAccelBoxIoSlot • cpqFcaCntlrModel • cpqFcaAccelSerialNumb

Página 80 - Storage agents 80

Storage agents 46 • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsFanModuleLocation • cpqSsFanModuleStatus • cpqSsFanModuleS

Página 81 - Storage agents 81

Storage agents 47 • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsPowerSupplyBay • cpqSsPowerSupplyUpsStatus Supporting SNMP

Página 82 - Server agents

Storage agents 48 • cpqTapeLibrarySerialNumber Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] is not operational.

Página 83 - Server agents 83

Storage agents 49 • cpqHoTrapFlags • cpqTapeLibrarySerialNumber Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] d

Página 84 - Server agents 84

Introduction 5 Where to go for additional help In addition to this guide, the following information sources are available: • User documentation

Página 85 - Event Identifiers 1024-1092

Storage agents 50 Symptom: Controller Status Change. This trap indicates that the agent has detected a change in the status of a drive array con

Página 86 - Server agents 86

Storage agents 51 cpqFcTapeCntlrStatus indicates the current tape controller status. The variable cpqFcTapeCntlrWWN indicates the unique tape co

Página 87 - Server agents 87

Storage agents 52 cpqFcTapeLibraryDoorStatus indicates the current tape library door status. The variable cpqFcTapeLibraryScsiTarget indicates t

Página 88 - Server agents 88

Storage agents 53 Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeCntlrWWN • cpqFcTapeDriveScsiBus • cpqFcTapeDriveScsiTar

Página 89 - Server agents 89

Storage agents 54 • cpqFcaCntlrBoxIoSlot Supporting SNMP Trap Description: “Controller in I/O slot [cpqFcaCntlrBoxIoSlot] is now active on chas

Página 90 - Server agents 90

Storage agents 55 • cpqDaTapeLibraryScsiLun • cpqDaTapeLibraryDoorStatus Supporting SNMP Trap Description: “The door is [cpqDaTapeLibraryDoorS

Página 91 - Server agents 91

Storage agents 56 NT Event ID: 1184 (Hex)0x843504a0 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Replace Cleanin

Página 92 - Server agents 92

Storage agents 57 SNMP Trap: cpqIdeAtaDiskStatusChange - 14004 in CPQIDE.MIB Symptom: ATA Disk Status Change. This trap indicates that the agent

Página 93 - Event Identifiers 1103-1183

Storage agents 58 Log Message: An enclosure attached to port %5 of storage system “%4” has a new fan status of %7. The enclosure model is “%6”.

Página 94 - Server agents 94

Storage agents 59 Supporting SNMP Trap Description: “Storage system temperature status changed to [cpqSsBackplaneTempStatus].” NT Event ID: 1190

Página 95 - Server agents 95

Foundation agents 6 Foundation agents Event Identifiers 256-774 Event identifier: cpqhsmsg.dll - 256 (Hex)0x84350100 (Service Event) Log Severit

Página 96 - Server agents 96

Storage agents 60 • cpqTapeLibraryFwRev • cpqTapeLibrarySerialNumber • cpqTapeLibraryState Supporting SNMP Trap Description: “Status is now [

Página 97 - Server agents 97

Storage agents 61 • cpqFcTapeDriveModel • cpqFcTapeDriveFWRev • cpqFcTapeDriveSerialNumber • cpqFcTapeDriveLocation • cpqFcTapeDriveStatus

Página 98 - Server agents 98

Storage agents 62 • cpqFcTapeDriveModel • cpqFcTapeDriveFWRev • cpqFcTapeDriveSerialNumber • cpqFcTapeDriveLocation Supporting SNMP Trap Des

Página 99 - Server agents 99

Storage agents 63 • cpqFcTapeLibraryScsiTarget • cpqFcTapeLibraryScsiLun • cpqFcTapeLibraryModel • cpqFcTapeLibraryFWRev • cpqFcTapeLibrary

Página 100 - Server agents 100

Storage agents 64 User Action: If the board status is generalFailure(3), you may need to replace the controller. If the board status is cablePro

Página 101 - Server agents 101

Storage agents 65 User Action: If the spare drive status is failed, replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags •

Página 102 - Server agents 102

Storage agents 66 SNMP Trap: cpqDa6PhyDrvThreshPassedTrap - 3037 in CPQIDA.MIB Symptom: Physical Drive Threshold Passed. This trap indicates tha

Página 103 - Server agents 103

Storage agents 67 Event Title: Drive Array Accelerator Bad Data. Log Message: The array accelerator board attached to the array controller in %4

Página 104 - Server agents 104

Storage agents 68 NT Event ID: 1207 (Hex)0x843504b7 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Library Status Change

Página 105 - Server agents 105

Storage agents 69 • cpqDaTapeLibraryModel • cpqDaTapeLibraryFWRev • cpqDaTapeLibrarySerialNumber • cpqDaTapeLibraryDoorStatus Supporting SNM

Página 106 - Server agents 106

Foundation agents 7 Event identifier: cpqhsmsg.dll - 264 (Hex)0x84350108 (Service Event) Log Severity: Warning (2) Log Message: The Foundation A

Página 107 - Server agents 107

Storage agents 70 • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex • cpqDaTapeDrvName • cpqDaTapeDrvFwRev • cpqDaTa

Página 108 - Server agents 108

Storage agents 71 • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor • cpqSsBoxModel • cpqSsBoxSerialNumbe

Página 109 - Server agents 109

Storage agents 72 User Action: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Da

Página 110 - Server agents 110

Storage agents 73 Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array

Página 111 - Server agents 111

Storage agents 74 NT Event ID: 1218 (Hex)0x843504c2 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Storage System Fan Status Change. Log

Página 112 - Server agents 112

Storage agents 75 • cpqSsBoxModel • cpqSsBoxSerialNumber • cpqSsBoxTempStatus • cpqSsBoxLocationString Supporting SNMP Trap Description: “St

Página 113 - Server agents 113

Storage agents 76 • cpqSasHbaHwLocation • cpqSasPhyDrvLocationString • cpqSasPhyDrvHbaIndex • cpqSasPhyDrvIndex • cpqSasPhyDrvStatus • cpq

Página 114 - Server agents 114

Storage agents 77 Event identifier: cpqstmsg.dll - 1283 (Hex)0x84350503 (Service Event) Log Severity: Warning (2) Log Message: Could not read th

Página 115 - Server agents 115

Storage agents 78 Log Message: The SNMP Agent is older than other components. The SNMP Agent is older than the other components of the Storage A

Página 116 - Server agents 116

Storage agents 79 Log Message: The IDE Agent could not allocate memory. The data contains the error code. Event identifier: cpqstmsg.dll - 3585

Página 117 - Server agents 117

Foundation agents 8 Log Message: The Foundation Agents service could not write the registry value “%1”. The data contains the error code. Event

Página 118 - Server agents 118

Storage agents 80 Log Message: The IDE Agent could not create its main thread of execution. The data contains the error code. Event identifier:

Página 119 - Server agents 119

Storage agents 81 Log Severity: Warning (2) Log Message: Could not read the registry subkey: “%1”. This error can be caused by a corrupt registr

Página 120 - Server agents 120

Server agents 82 Server agents Event Identifiers 256-774 Event identifier: cpqsvmsg.dll - 256 (Hex)0x84350100 (Service Event) Log Severity: Warn

Página 121 - Server agents 121

Server agents 83 Log Severity: Warning (2) Log Message: The Server Agents service could not load the module “%1”. The data contains the error co

Página 122 - Server agents 122

Server agents 84 Log Severity: Error (3) Log Message: The Server Agents service encountered a fatal error. The service is terminating. The data

Página 123 - Server agents 123

Server agents 85 Event Identifiers 1024-1092 NT Event ID: 1024 (Hex)0xc4350400 (cpqsvmsg.dll) Log Severity: Error (3) Log Message: A cache accel

Página 124 - Event Identifiers 1539-3352

Server agents 86 NT Event ID: 1027 (Hex)0x84350403 (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: The Advanced Memory Protection sub-syst

Página 125 - Server agents 125

Server agents 87 NT Event ID: 1030 (Hex) 0x44350406 (cpqsvmsg.dll) Log Severity: Information (1) Log Message: The Fan Sub-system has returned to

Página 126 - Event Identifiers 5632-5684

Server agents 88 User Action: Be sure that the board, cartridge, or riser memory is installed correctly, and then re-install the memory board, c

Página 127 - Server agents 127

Server agents 89 • cpqHeResMem2BoardRiserNum Supporting SNMP Trap Description: “Memory Board or Cartridge Inserted into Slot [cpqHeResMem2Board

Página 128 - Server agents 128

Foundation agents 9 Log Message: The Host Remote Alerter received an error on WaitForMultipleObjects call. The data contains the error code. Eve

Página 129 - NIC agents

Server agents 90 • cpqHoTrapFlags Supporting SNMP Trap Description: “System will be shut down due to this thermal condition.” NT Event ID: 1083

Página 130 - NIC agents 130

Server agents 91 NT Event ID: 1086 (Hex)0x8435043e (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: A System Fan Condition has been set to

Página 131 - NIC agents 131

Server agents 92 SNMP Trap: cpqHe3ThermalCpuFanOk - 6024 in CPQHLTH.MIB Symptom: The CPU fan status has been set to OK. Any previously non-opera

Página 132 - NIC agents 132

Server agents 93 Supporting SNMP Trap Description: “Errors occurred during server restart.” Event Identifiers 1103-1183 NT Event ID: 1103 (Hex)0

Página 133 - Event Identifiers 300-1293

Server agents 94 Log Message: The Remote Insight Board has detected self test error '%4'. SNMP Trap: cpqSm2SelfTestError - 9005 in CPQ

Página 134 - NIC agents 134

Server agents 95 • cpqHoTrapFlags Supporting SNMP Trap Description: “Remote Insight keyboard cable disconnected.” NT Event ID: 1114 (Hex)0x8435

Página 135 - NIC agents 135

Server agents 96 Supporting SNMP Trap Description: “Remote Insight mouse cable disconnected.” NT Event ID: 1117 (Hex)0x8435045d (cpqsvmsg.dll) L

Página 136 - NIC agents 136

Server agents 97 Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: “Errors occurred during server restar

Página 137 - NIC agents 137

Server agents 98 • cpqHeFltTolPowerSupplySerialNumber • cpqHeFltTolPowerSupplyAutoRev • cpqHeFltTolPowerSupplyFirmwareRev • cpqHeFltTolPower

Página 138 - NIC agents 138

Server agents 99 Symptom: A Fault Tolerant Power Supply has been removed from the specified chassis and bay location. Supporting SNMP Trap Data: