HP 4100 Enterprise Virtual Array Manual do Utilizador Página 158

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 180
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 157
Risks
Single path failure may result in data loss or disk corruption.
NOTE: For additional risks, see Table 63 (page 161).
Limitations
HP P6000 Continuous Access is not supported with single path configurations.
Single path HBA server is not part of a cluster.
Booting from the SAN is supported on single path HBA servers.
Figure 59 VMware configuration
5 SAN switch 11 Network interconnection
6 SAN switch 22 Single HBA server
7 Controller A3 Dual HBA server
8 Controller B4 Management server
Failure scenarios
HP-UX
Table 57 HP-UX failure scenarios
Failure effectFault stimulus
Extremely critical event on UNIX. Can cause loss of system disk.Server failure (host power-cycled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Switch failure (SAN switch disabled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller failure
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Controller restart
158 Single Path Implementation
Vista de página 157
1 2 ... 153 154 155 156 157 158 159 160 161 162 163 ... 179 180

Comentários a estes Manuais

Sem comentários