Table 3-7 Get device status (continued)
Response Code 200 OK — success
401 Unauthorized access — if basic authentication fails
500 Internal Server Error — if too many requests are active. Retry recommended.
Schema Request
Response
?api=config&rschema=getDeviceStatus
Figure 3-8 Get device status, response example
Table 3-8 ADF Status possible values
Code Meaning Explanation
1 Ready There is paper for scan
0 Empty There is no paper for scan
-1 Initializing Device is still booting
–2 Unsupported Device does not support ADF/Flatbed status monitoring
-3 Not present Device has no ADF/Flatbed
3.2.3 Get solution info
Table 3-9 Get solution info
?api=config&method=getSolutionInfo
GET Description Returns solution information. Information returned includes:
Solution version
License information
Blocked for users (through the accessibility block command)
Log level (all, off)
AdvancedWorkflowSupport (true, false)