DP2 FCHECK User’s Guide August 25, 2005
Hewlett-Packard Development Company L.P.
1
1
of
1
3
NTL Support and Service Library
9. Detailed Information for Broken Files
The FCHECK utility displays information about three major file-structure
problems:
o Broken block
o Block checksum error
o Broken key-sequenced B-tree structure
For a broken block header or block checksum error, FCHECK displays:
>>> Bad Block code: BLK^19
Block RSN: 0 Expected RSN: 0
Flags: %100000 Expected Flags: %006400
Records: 31309 Error Recnum: ----------
Blk Level: 0 File Levels: 0
Prev RSN: -1 Next RSN: -1
>>>>>>> KS: wrong block type
The block code equates to an internal symptom string generated by the
disk process and is translated in the last line of the preceding display. In
this case, the block flags do not match what is expected.