Hp ProLiant DL560 Server Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware de computador Hp ProLiant DL560 Server. HP ProLiant DL560 Server User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 136
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - User Guide

HP ProLiant DL560 Server User Guide

Página 2 - Audience Assumptions

10 HP ProLiant DL560 Server User Guide Item Description Status 1 CD-ROM drive ejector button NA 2 UID LED button Blue = Activated Flashing =

Página 3 - Contents

100 HP ProLiant DL560 Server User Guide Server Error Messages The following POST error messages are new to some ProLiant servers. For a complete lis

Página 4

Server Specific Troubleshooting 101 − Check the status using the power supply LEDs on the rear panel ("Rear Panel LEDs and Buttons" on

Página 5

102 HP ProLiant DL560 Server User Guide The operating system loads to complete the boot process. If the server completes POST and attempts to load t

Página 6

Server Specific Troubleshooting 103 Is the System Power LED Amber? Answer Possible Reasons Possible Solutions No The server is not connected to

Página 7

104 HP ProLiant DL560 Server User Guide Is the System Power LED Green? Answer Possible Reasons Possible Solutions No Power On/Standby button has

Página 8 - Front Panel Components

Server Specific Troubleshooting 105 Is the Internal Health LED Green? Answer Possible Reasons Possible Solutions No, it is amber A processor or

Página 9 - Front Panel LEDs and Buttons

106 HP ProLiant DL560 Server User Guide Is the Monitor Displaying Information? Answer Possible Reasons Possible Solutions No The monitor may not

Página 10 - HP CONFIDENTIAL

Server Specific Troubleshooting 107 System Cannot Load SmartStart Possible Cause Possible Solution A SmartStart requirement is not met. Check

Página 11 - Rear Panel Components

108 HP ProLiant DL560 Server User Guide SmartStart Cannot Load Operating System Possible Cause Possible Solution Required operating system step

Página 12 - Rear Panel LEDs and Buttons

Server Specific Troubleshooting 109 3. Insert the ROMPaq diskette. 4. Power up the server ("Powering Up the Server" on page 29). a. T

Página 13 - System Board Components

Server Component Identification 11 Rear Panel Components Item Description Connector Color 1 Slot 1, 64-bit/133-MHz PCI-X, bus 3 N/A 2 Slot

Página 14 - NMI Switch

110 HP ProLiant DL560 Server User Guide For information on warranties and service and support upgrades (CarePaq services), refer to the HP website (

Página 15 - DIMM Slots

111 Battery Replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provi

Página 16 - System Maintenance Switch

112 HP ProLiant DL560 Server User Guide 5. Remove the battery. IMPORTANT: Replacing the system board battery resets the system ROM to its defaul

Página 17 - System Board LEDs

113 Regulatory Compliance Notices In This Section Regulatory Compliance Identification Numbers ...

Página 18

114 HP ProLiant DL560 Server User Guide Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Re

Página 19

Regulatory Compliance Notices 115 Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device,

Página 20

116 HP ProLiant DL560 Server User Guide • • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 1-281-514-3333 To i

Página 21

Regulatory Compliance Notices 117 Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Can

Página 22 - SCSI Backplane Components

118 HP ProLiant DL560 Server User Guide Japanese Notice Taiwanese Notice HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02

Página 23

Regulatory Compliance Notices 119 Laser Device Notices All HP systems equipped with a laser device comply with safety standards, including Internati

Página 24

12 HP ProLiant DL560 Server User Guide Rear Panel LEDs and Buttons Item Description LED Color Status 1 RJ-45 activity LED Green On or flash

Página 25 - Remote Management Connector

120 HP ProLiant DL560 Server User Guide Laser Product Label The following label or equivalent is located on the surface of the laser product. This

Página 26 - Hot-Plug Fans

Regulatory Compliance Notices 121 Battery Replacement Notice WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pen

Página 28 - Off = No power

123 Electrostatic Discharge In This Section Preventing Electrostatic Discharge...

Página 29 - Server Operations

124 HP ProLiant DL560 Server User Guide Grounding Methods to Prevent Electrostatic Discharge Several methods are used for grounding. Use one or more

Página 30

125 Server Specifications In This Section Server Dimensions and Weight ...

Página 31 - Server Operations 31

126 HP ProLiant DL560 Server User Guide Environmental Specifications Temperature range Operating 10°C to 35°C (50°F to 95°F) Shipping -40°C to

Página 32 - Removing the PCI Riser Cage

127 Technical Support In This Section Related Documents...

Página 33 - Server Operations 33

128 HP ProLiant DL560 Server User Guide • • • • Applicable error messages Add-on boards or hardware Third-party hardware or software Operating syste

Página 34 - Removing the Power Module

129 Acronyms and Abbreviations A ABEND abnormal end ASR Automatic Server Recovery D DDR double data rate DIMM dual inline memory module E ECC

Página 35 - 3. Remove power module

Server Component Identification 13 System Board Components HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM

Página 36 - Installing the Power Module

130 HP ProLiant DL560 Server User Guide I IML Integrated Management Log N NEMA National Electrical Manufacturers Association NFPA National Fire Pr

Página 37 - Server Setup

Acronyms and Abbreviations 131 PDU power distribution unit POST Power-On Self-Test PPM Processor Power Module PXE preboot execution environment

Página 38 - Rack Planning Resources

132 HP ProLiant DL560 Server User Guide U UID unit identification HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM

Página 39 - Optimum Environment

133 crash dump analysis 14 Index D DC-to-DC converter 55 deployment software 90 A diagnostic steps 102 diagnostic tools 83, 89, 90, 93,

Página 40 - Temperature Requirements

134 HP ProLiant DL560 Server User Guide L front panel buttons 9 front panel components 8 laser devices 119 front panel LEDs 9 LEDs 7 G M g

Página 41 - Power Requirements

Index 135 PCI slots 11 rear panel buttons 12 PCI-X boards 11, 75 rear panel connectors 11 peripheral board interlock LED 17, 19 rear pane

Página 42 - Rack Warnings

HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM 136 HP ProLiant DL560 Server User Guide system board battery 111, 12

Página 43 - Installing Hardware Options

14 HP ProLiant DL560 Server User Guide Item Description Item Description 1 DIMM slots (1-6) 12 Processor socket 4 2 Smart Array 5i Plus Memo

Página 44

Server Component Identification 15 Chassis ID Switch The chassis ID switch on the system board is reserved for use by authorized technicians only. D

Página 45 - 1. Mark the rack

16 HP ProLiant DL560 Server User Guide System Maintenance Switch Position Default Function S1 Off Reserved S2 Off Off = System configuration ca

Página 46

Server Component Identification 17 System Board LEDs HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM

Página 47 - Server Setup 47

18 HP ProLiant DL560 Server User Guide Item LED Description Status 1 Processor 1 failure Amber = Processor failed Off = Normal 2 Processor 2

Página 48

Server Component Identification 19 Item LED Description Status 14 PPM 4 failure Amber = PPM failed Off = Normal 15 PPM 3 failure Amber = PPM f

Página 49 - Server Setup 49

© 2002 Hewlett-Packard Development Company, L.P. Microsoft, MS-DOS, Windows, and Windows NT are trademarks of Microsoft Corporation in the U.S. and o

Página 50

20 HP ProLiant DL560 Server User Guide The front panel health LEDs indicate only the current hardware status. In some situations, Insight Manager 7

Página 51 - Server Setup 51

Server Component Identification 21 System LED and Color Internal Health LED Color Status Processor failure, socket X (Amber) Red • • • • • Process

Página 52

22 HP ProLiant DL560 Server User Guide System LED and Color Internal Health LED Color Status Online spare memory (Amber) Amber Bank X failed over to

Página 53 - Registering the Server

Server Component Identification 23 Hot-Plug SCSI Hard Drive LEDs Item LED Description Status 1 Activity status On = Drive activity Flashing

Página 54

24 HP ProLiant DL560 Server User Guide Hot-Plug SCSI Hard Drive LED Combinations Activity LED Online LED Fault LED Means On Off Off Do not remove

Página 55 - Processor Option

Server Component Identification 25 PCI Riser Cage LED Status On = system power connected Off = system power disconnected CAUTION: To pr

Página 56

26 HP ProLiant DL560 Server User Guide Hot-Plug Fans HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM

Página 57

Server Component Identification 27 Item Description Fan Zone 1 Fan 1 Processor 2 Fan 2 Processor 3 Fan 3 Processor 4 Fan 4 Processor 5 Fan 5

Página 58 - 8. Install the PPM

28 HP ProLiant DL560 Server User Guide Status Green = Operating normally Amber = Failed Off = No power HP CONFIDENTIAL File Name: 303212-1new.d

Página 59 - Memory Options

29 Server Operations In This Section Powering Up the Server...

Página 60 - DIMM Installation Guidelines

3 Contents Server Component Identification 7 Front Panel Components...

Página 61 - Installing DIMMs

30 HP ProLiant DL560 Server User Guide 4. Press the Power On/Standby button to place the server in standby mode (2). When the server activates stan

Página 62

Server Operations 31 WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized before ex

Página 63 - Removing a Hard Drive Blank

32 HP ProLiant DL560 Server User Guide Removing the Access Panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the driv

Página 64

Server Operations 33 5. Remove the PCI riser cage. Installing the PCI Riser Cage CAUTION: To prevent damage to the server or expansion boards,

Página 65 - Hot-Plug Tape Drive Option

34 HP ProLiant DL560 Server User Guide 2. Tighten the thumbscrews to secure the PCI riser cage: a. Lift the thumbscrew knobs (1). b. Turn the thu

Página 66

Server Operations 35 2. Disconnect internal power cables. 3. Remove power module. HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On:

Página 67

36 HP ProLiant DL560 Server User Guide Installing the Power Module 1. Install the power module. 2. Connect internal power cables ("Internal

Página 68

HP CONFIDENTIAL File Name: 303212-1.doc Last Saved On: 11/4/02 2:36 PM 37 Server Setup In This Section Optional Installation Services...

Página 69

38 HP ProLiant DL560 Server User Guide For a list of operating systems, supported by the server, refer to the HP website (ftp://ftp.compaq.com/pub/p

Página 70 - Installation Requirements

Server Setup 39 Optimum Environment When installing the server in a rack, select a location that meets the environmental standards described in th

Página 71 - 4. Install a fan

4 HP ProLiant DL560 Server User Guide Temperature Requirements...

Página 72

40 HP ProLiant DL560 Server User Guide CAUTION: When using a Compaq branded 7000 Series rack, you must install the high airflow rack door insert

Página 73

Server Setup 41 Power Requirements Installation of this equipment must comply with local and regional electrical regulations governing the install

Página 74

42 HP ProLiant DL560 Server User Guide Electrical Grounding Requirements The server must be grounded properly for proper operation and safety. In th

Página 75 - Expansion Board Options

Server Setup 43 WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack: At least two people are needed to saf

Página 76

44 HP ProLiant DL560 Server User Guide • Options to be installed Item Description 1 Server rails 2 Left and right standard rack rail assemblies 3

Página 77

Server Setup 45 WARNING: When installing a server in a telco rack, be sure that the rack frame is adequately secured to the top and bottom of t

Página 78

46 HP ProLiant DL560 Server User Guide NOTE: Rack components are removed for clarity. 2. Secure each server rail to the server. 3. Secure each

Página 79 - Server Cabling

Server Setup 47 WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized before slidi

Página 80 - RILOE II Cabling

48 HP ProLiant DL560 Server User Guide WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release latches a

Página 81 - Server Cabling 81

Server Setup 49 7. Secure the cable management arm bracket to the server. NOTE: Cable management arm is removed for clarity. 8. Secure the ca

Página 82

Contents 5 SmartStart Autorun Menu...89 SmartS

Página 83 - ROM-Based Setup Utility

50 HP ProLiant DL560 Server User Guide WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or

Página 84 - Auto-Configuration Process

Server Setup 51 Item Description Connector Color 1 Slot 1, 64-bit/133-MHz PCI-X, bus 3 N/A 2 Slot 2, 64-bit/100-MHz PCI-X, bus 6 N/A 3 Sl

Página 85 - Boot Options

52 HP ProLiant DL560 Server User Guide 12. Secure cables to the cable management arm. 13. Connect the power cord to the power source. Powering

Página 86 - System Maintenance Menu

Server Setup 53 Installing the Operating System To operate properly, the server must have a supported operating system. For the latest information

Página 88 - SmartStart Software

55 Hardware Options Installation In This Section Processor Option ...

Página 89 - SmartStart Scripting Toolkit

56 HP ProLiant DL560 Server User Guide The server uses Processor Power Modules (PPMs) as DC-to-DC converters to provide the proper power to each pro

Página 90 - Drivers

Hardware Options Installation 57 4. Lift the removable media tray. 5. Open the processor locking lever. CAUTION: Failure to open the proces

Página 91 - Redundant ROM Support

58 HP ProLiant DL560 Server User Guide CAUTION: To prevent possible server malfunction or damage to the equipment, be sure to align the processor

Página 92 - Safety and Security Benefits

Hardware Options Installation 59 NOTE: The appearance of compatible PPMs may vary. 9. Lower the removable media tray. IMPORTANT: If upgradin

Página 93 - ROMPaq Utility

6 HP ProLiant DL560 Server User Guide Declaration of Conformity for Products Marked with the FCC Logo, United States Only ... 115 Modifica

Página 94 - Automatic Server Recovery-2

60 HP ProLiant DL560 Server User Guide Refer to "DIMM Slots (on page 15)" for DIMM slot locations and bank assignments. Online Spare Memo

Página 95 - Insight Manager 7

Hardware Options Installation 61 • Upgrade memory by installing DIMM pairs into banks in sequential bank order, starting with bank B. For online

Página 96 - Integrated Management Log

62 HP ProLiant DL560 Server User Guide Hot-Plug SCSI Hard Drive Options When adding SCSI hard drives to the server, observe the following general gu

Página 97 - Foundation Pack

Hardware Options Installation 63 Removing a Hard Drive Blank CAUTION: To prevent improper cooling and thermal damage, do not operate the server

Página 98

64 HP ProLiant DL560 Server User Guide Installing a Hot-Plug SCSI Hard Drive 1. Remove the existing hard drive blank or hard drive from the drive

Página 99

Hardware Options Installation 65 Hot-Plug Tape Drive Option 1. Remove the existing hard drive blank or hard drive from the upper-left drive bay (

Página 100 - Server Error Messages

66 HP ProLiant DL560 Server User Guide Battery-Backed Write Cache Enabler Option The Battery-Backed Write Cache Enabler, also known as the battery

Página 101

Hardware Options Installation 67 3. Remove the access panel ("Removing the Access Panel" on page 32). 4. Remove the PCI riser cage (&q

Página 102 - Diagnostic Steps

68 HP ProLiant DL560 Server User Guide 7. Install the battery module assembly and connect the cable to the memory module. 8. Install the PCI ris

Página 103

Hardware Options Installation 69 − The BIOS suspends the server for 5 minutes if a cautionary temperature level is detected. If the cautionary te

Página 104

7 Server Component Identification In This Section Front Panel Components ...

Página 105

70 HP ProLiant DL560 Server User Guide Installation Requirements WARNING: To reduce the risk of electric shock, personal injury, and damage to th

Página 106 - Problems After Initial Boot

HP CONFIDENTIAL File Name: 303212-1.doc Last Saved On: 11/4/02 2:36 PM Hardware Options Installation 71 3. Lift the removable media tray. 4.

Página 107

72 HP ProLiant DL560 Server User Guide 7. Lower the removable media tray. 8. Install the access panel ("Installing the Access Panel" o

Página 108 - ROMPaq Disaster Recovery

Hardware Options Installation 73 Redundant Hot-Plug AC Power Supply Option CAUTION: To prevent improper cooling and thermal damage, do not oper

Página 109 - Other Information Resources

74 HP ProLiant DL560 Server User Guide 3. Remove the protective cover from the connector pins on the power supply. WARNING: To reduce the risk o

Página 110

Hardware Options Installation 75 NOTE: If using the power cord anchor, be sure to leave enough slack in the power cord so that the redundant powe

Página 111 - Battery Replacement

76 HP ProLiant DL560 Server User Guide CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC powe

Página 112 - 5. Remove the battery

Hardware Options Installation 77 7. Install the expansion board and lock the PCI retaining clip. 8. Install the PCI riser cage ("Installi

Página 114 - Class A Equipment

79 Server Cabling In This Section Power Button and Drive Cabling...

Página 115 - Class B Equipment

8 HP ProLiant DL560 Server User Guide Front Panel Components Item Description 1 SCSI hard drive bay 1 (SCSI ID 0) 2 SCSI hard drive bay 2 (SCS

Página 116 - Canadian Notice

80 HP ProLiant DL560 Server User Guide Item Description 1 SCSI cable 2 Power button cable 3 Diskette drive cable 4 CD-ROM drive cable Interna

Página 117 - European Union Notice

Server Cabling 81 HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM

Página 119 - Laser Device Notices

83 Server Configuration and Utilities In This Section ROM-Based Setup Utility ...

Página 120 - Laser Information

84 HP ProLiant DL560 Server User Guide For more information on RBSU, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD or t

Página 121 - Battery Replacement Notice

Server Configuration and Utilities 85 NOTE: The server may not support all of the following examples. Drives Installed Drives Used RAID Le

Página 122

86 HP ProLiant DL560 Server User Guide Configuring Online Spare Memory To configure online spare memory: 1. Install the required DIMMs ("Memo

Página 123 - Electrostatic Discharge

Server Configuration and Utilities 87 • • • • • The ROM-Based Diagnostic Utility provides a preboot method for quickly checking the validity of th

Página 124 - Discharge

88 HP ProLiant DL560 Server User Guide 2. Press the F8 key when prompted during POST. The iLO RBSU runs. 3. Enter a valid iLO user ID and password

Página 125 - Server Specifications

Server Configuration and Utilities 89 • • • • • Install the latest optimized drivers. Create and copy standard server configuration scripts using

Página 126

Server Component Identification 9 Front Panel LEDs and Buttons HP CONFIDENTIAL File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM

Página 127 - Technical Support

90 HP ProLiant DL560 Server User Guide Enterprise Diagnostics LX32 Utility The Enterprise Diagnostics LX32 Utility displays information about the se

Página 128

Server Configuration and Utilities 91 For more information on drivers, refer to the Servers Troubleshooting Guide on the Documentation CD. USB Su

Página 129 - Acronyms and Abbreviations

92 HP ProLiant DL560 Server User Guide Safety and Security Benefits When you flash the system ROM, ROMPaq writes over the backup ROM and saves the c

Página 130

Server Configuration and Utilities 93 When the server boots, the system identifies whether the current ROM bank is corrupt. If a corrupt ROM is de

Página 131

94 HP ProLiant DL560 Server User Guide • Automatically checks for hardware, firmware, and operating system dependencies, and installs only the corr

Página 132

Server Configuration and Utilities 95 ASR-2 increases server availability by restarting the server within a specified time after a system hang or

Página 133

96 HP ProLiant DL560 Server User Guide Survey Utility Survey Utility gathers critical hardware and software information on servers running Microsoft

Página 134

Server Configuration and Utilities 97 For more information, refer to the Servers Troubleshooting Guide on the Documentation CD, or the Management

Página 136

99 Server Specific Troubleshooting In This Section Minimum Hardware Configuration ................

Comentários a estes Manuais

Sem comentários