Hp CD Leycom CFL-512 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Hp CD Leycom CFL-512. HP CD Leycom CFL-512 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 5
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Leycom
®
CFL-512 and Conduct NT
CD Leycom September 2004
The LEYCOM
®
Cardiac Function Lab CFL-512 facilitates the on-line
measurement and analysis of ventricular pressure and volume signals in clinical
setting. The pressure and volume signals are obtained using a combined
conductance and pressure catheter. The CFL-512 acquires and displays these
signals on-line and continuously. The signals are digitized, stored and can be
subsequently played back and analyzed the users convenience.
The Leycom
®
CFL-512 is a stand-alone device, which can be easily used in
different clinical environments. The system, including the software for data
acquisition and analysis, has been developed in close co-operation with a group
of clinical users of Leycom
®
equipment.
The Leycom
®
CFL-512 consists of a bedside 'patient module' and a console.
The bedside 'patient module' is a state of the art, battery powered, data
acquisition module. The module, to which the conductance catheter is
connected, contains sophisticated circuitry, which ensures optimal patient safety
and extended battery life.
The 'patient module' is communicates with the Leycom
®
CFL-512 console via
a fibre optic cable; this provides complete patient isolation from electrical
hazard.
The
dedicated computer
is Intel Pentium based, has a 40 Gb harddisk, enough
for hundreds of hours of data acquisition, at 12 channels and 250 samples per
second.
With the Leycom
®
CFL-512 software, time-varying ventricular volume,
pressure, ECG, a large number of hemodynamic variables and Pressure-volume
loops can be displayed. The slope and intercept of the end-systolic pressure-
volume relation (a measure of ventricular performance) are calculated, as well as
other related variables.
CD Leycom info 0310 V0440
Vista de página 0
1 2 3 4 5

Resumo do Conteúdo

Página 1 - CFL-512 and Conduct NT

Leycom® CFL-512 and Conduct NT CD Leycom September 2004 The LEYCOM® Cardiac Function Lab CFL-51

Página 2 - CFL-512

CFL-512 Conduct NT – for clinical evaluation only A Microsoft Windows based acquisition, display and analysis program has been developed for th

Página 3

CFL-512 Conduct NT – Analyse Recorded Data Conductance Catheter Settings Match the catheter with the actual

Página 4

CFL-512 Conduct NT – Analyse Recorded Data Select data file Retrieve previously acquired data files for subsequent

Página 5 - Highlights

CFL-512 Highlights u Hardware Software Console • Pentium, 1 GHz with 256 Mb RAM • Dedicated hardware for: Acquisition of external signals Commu

Comentários a estes Manuais

Sem comentários