B-1
Cables and Connectors
B
Cables and Connectors
This appendix includes hub connector information and network cable infor-
mation for cables that should be used with the HP 10/100 hubs, including
minimum pin-out information for twisted-pair cables.
Note Incorrectly wired cabling is the most common cause of problems for LAN
communications. HP recommends that you work with a qualified LAN cable
installer for assistance with your cabling requirements.
Twisted-Pair Cable/Connector Pin-Outs
The RJ-45 10/100Base-T ports on the HP 10/100 hubs are wired as MDI-X ports.
Port 1 on each hub can be changed to an MDI port by pressing the MDI-X/MDI
switch on the front of the hub to the MDI position. The type of twisted-pair
cable you connect to these ports (either “straight-through” or “crossover”)
depends on the type of device at the other end of the cable.
The basic rule is, when connecting same-type ports together (for example
MDI-X-to-MDI-X), use crossover cable; when connecting opposite-type ports
together (for example MDI-X-to-MDI), use straight-through cable.
These additional rules apply:
All twisted-pair wires used for 10 Mbps and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-B (not USOC). See “Twisted-Pair Cable Pin
Assignments” later in this appendix for a listing of the signals used on each
pin.
For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
unshielded twisted-pair cable, as supported by the IEEE 802.3 Type
10Base-T standard.
For 100 Mbps connections to the ports, use 100-ohm Category 5 UTP cable
only, as supported by the IEEE 802.3u Type 100Base-TX standard.