NOTE: HP DL380z Gen8 Virtual Workstations are primarily connected to power distribution
units (PDUs) in data center racks and now ship standard with a PDU 6-foot C-14 to C13 power
cord (A0K02A). If a user wishes to power an HP DL380z using a 110V receptacle (NEMA-15),
the 6-foot NEMA 5-15 to C13 power cord must be ordered separately (AF556A). See Power
Cords section for Worldwide Power Cord options.
To review typical system power ratings use the HP Power Advisor which is available via the
online tool located at URL: www.hp.com/go/hppoweradvisor.
NOTE: Power Specification and Technical Content for supported power supplies can be found
at: http://h18000.www1.hp.com/products/quickspecs/14209_div/14209_div.html
NOTE: Mixing of power supplies in the same system is not supported. All power supplies inside
a system must be exactly the same model. Mixing Gold, Platinum, and Platinum Plus certified
power supplies is not supported.
HP's Common Slot (CS) power supplies allow for commonality of power supplies across a wide
range of ProLiant, HP Virtual Workstation, and Integrity servers, as well as HP Storage
solutions, and are designed to provide the highest power supply efficiency without degrading
system performance. HP CS power supplies are tested by the Electric Power Research
Institute (EPRI) and certified through the ECOS 80 Plus power supply program. HP CS power
supply options provide efficiency ratings of up to 94% (80 Plus Platinum). Only the 1200W
power supply is available for the DL380z Gen8 Virtual Workstation. All HP Common Slot power
sources are UL, CE Mark Compliant, hot-plug and support redundant configurations.
NOTE: Mixing of power supplies in the same system is not supported. All power supplies must
be of the same output and efficiency rating. If non-matched power supplies are inserted you will
get errors and operation will fail.
HP CS Platinum Plus power supplies are required when enabling HP's Intelligent Power
Discovery (IPD) solution. IPD is the first technology to create an automated, energy-aware
network between IT systems and facilities. This allows your company to reclaim millions of
dollars in wasted power capacity and downtime costs across data centers. For more
information on HP's IPD solution, go to www.hp.com/go/ipd.