HP IO Accelerator version 3.1.1 VMware ESX and
ESXi
User Guide
Abstract
This document describes software requirements for all relevant HP IO Accelerators using VMware ESX or ESXi operating systems.
This document is
intended for system administrators who
plan to install and use HP IO Accelerators with a VMware ESX or ESXi operating system. It is helpful to have
previous experience with HP IO Accelerators and a VMware ESX or ESXi operating system. This user guide is intended for IO Acc
elerator software
release 3.1.1 or later.
Part Number: 682240-001
May 2012
Edition: 1
Vista de página 0
1 2 3 4 5 6 ... 57 58

Resumo do Conteúdo

Página 1 - User Guide

HP IO Accelerator version 3.1.1 VMware ESX and ESXi User Guide Abstract This document describes software requirements for all relevant HP IO Acceler

Página 2

Introduction 10 • Sufficient RAM to operate—The amount of RAM that the driver requires to manage the NAND flash varies according to the block size

Página 3 - Contents

Introduction 11 IO Accelerators cannot be installed as part of an ESX or ESXi installation.

Página 4 - Contents 4

Software installation 12 Software installation VMDirectPathIO The VSL software is only required for ESX or ESXi if you plan to use the IO Accelerato

Página 5 - About this guide

Software installation 13 Installation overview Before installing the IO Accelerator driver, make sure you have properly installed the IO Accelerator

Página 6 - Introduction

Software installation 14 Transferring the VSL files to the ESX or ESXi server You must transfer the firmware file to the ESX or ESXi host. Depending

Página 7 - Performance attributes

Software installation 15 Installing the VSL on ESXi 5.0 These instructions describe how to install the VSL on a single hypervisor. However, if you a

Página 8 - Supported hardware

Software installation 16 Installing the VSL on ESX or ESXi 4.x using vCLI IMPORTANT: Do not save the installation bundles to the ESX or ESXi 4.x

Página 9 - Introduction 9

Software installation 17 NOTE: When using PCI pass-through, if you upgrade the firmware on an IO Accelerator, you must cycle the power for the ch

Página 10 - Before you begin

Software installation 18 CAUTION: Upgrading IO Accelerator devices that were previously configured for VSL 1.x.x or 2.x.x to work with VSL 3.x.x r

Página 11 - Introduction 11

Software installation 19 c. Reboot the system. 4. Update the firmware on each device to the latest version using the fio-update-iodrive TSM or COS

Página 12 - Software installation

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Página 13 - Installation overview

Software installation 20 CAUTION: ESX and ESXi require 512B sector sizes. New IO Accelerator devices come pre-formatted with 512B sector sizes fro

Página 14 - • SCP (using SSH)

Software installation 21 An ESXi host has the following: • Memory capacity of 36,852 MB • Total IO Accelerator device datastore capacity of 320 GB

Página 15

Maintenance 22 Maintenance Maintenance tools The IO Accelerator includes both software utilities to maintain the device and external LED indicators

Página 16

Maintenance 23 Command line utility Purpose fio-format (on page 32) Used to perform a low-level format of an IO Accelerator fio-pci-check (ESX only)

Página 17 - Upgrading procedure

Maintenance 24 Important considerations • If you are installing more than one dual IO Accelerator device and enabling the override parameter for ea

Página 18

Maintenance 25 1149D0969,1159E0972,24589 NOTE: The remote option (--server) is only required for the vCLI. 3. Reboot the system to enable the

Página 19 - Enabling PCIe power

Maintenance 26 Disabling auto attach When the IO Accelerator driver is installed, it is configured to automatically attach any devices when the driv

Página 20

Maintenance 27 vihostupdate --server <server-name> --query Sample output: ---------Bulletin ID--------- iomemory-vsl-2.2.0.7601742 -----Instal

Página 21 - Software installation 21

Performance and tuning 28 Performance and tuning Introduction to performance and tuning HP IO Accelerator devices provide high bandwidth and high IO

Página 22 - Maintenance

Utilities 29 Utilities Utilities reference These command-line utilities are only accessible through VMware TSM, also known as SSH, on ESXi and the C

Página 23 - Enabling PCIe power override

Contents 3 Contents About this guide ...

Página 24

Utilities 30 NOTE: If multiple IO Accelerator devices are installed in a computer, they attach in parallel. Syntax fio-attach <device> [

Página 25 - Common maintenance tasks

Utilities 31 NOTE: If the utility recommends that you contact Fusion-io support, disregard that message and contact HP support (http://www.hp.com

Página 26 - Enabling auto attach

Utilities 32 For example, the filename for a bug report file named fio-bugreport-20111006.173256-sc07HE.tar.gz indicates the following: • Date (201

Página 27 - Unmanaged shutdown issues

Utilities 33 Syntax fio-format [options] <device> where <device> is the name of the device node (/dev/fctx), where x indicates the card

Página 28 - Performance and tuning

Utilities 34 fio-pci-check [options] Options Description -d <value> 1 = Disable the link; 0 = bring the link up (HP does not recommend this

Página 29 - Utilities

Utilities 35 IMPORTANT: Starting with version 3.0.0 and later, the standard formatting of the fio-status output changed. The changing of the forma

Página 30

Utilities 36 o Date of manufacture o Power loss protection status o PCIe bus voltage (average, minimum, maximum) o PCIe bus current (average, max

Página 31 - Utilities 31

Utilities 37 To ensure a clean firmware update, you must detach the device from the system using the fio-detach utility. For more information, see &

Página 32 - • Date (20111006)

Utilities 38 CAUTION: Use the -f option with care because it might damage your board. CAUTION: Use the {{-d}} option with care, because upda

Página 33

Monitoring IO Accelerator health 39 Monitoring IO Accelerator health NAND flash and component failure The IO Accelerator is a highly fault-tolerant

Página 34

Contents 4 Introduction to performance and tuning ...

Página 35 - Utilities 35

Monitoring IO Accelerator health 40 Lifetime data volumes: Physical bytes written: 6,423,563,326,064 Physical bytes read : 5,509,006,756,312 Fl

Página 36 - • Block device information

Module parameters 41 Module parameters Using module parameters The following table describes the module parameters you can set using the esxcfg-modu

Página 37

VMDirectPathIO 42 VMDirectPathIO Working with IO Accelerators and VMDirectPathIO Each IO Accelerator device can either be used as a VMFS datastore i

Página 38 - Utilities 38

Resources 43 Resources Subscription service HP recommends that you register your product at the Subscriber’s Choice for Business website (http://www

Página 39 - Health monitoring techniques

Support and other resources 44 Support and other resources Before you contact HP Be sure to have the following information available before you call

Página 40

Support and other resources 45 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Página 41 - Module parameters

Support and other resources 46 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Página 42 - VMDirectPathIO

Support and other resources 47 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Página 43 - Resources

Support and other resources 48 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Página 44 - Support and other resources

Support and other resources 49 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Página 45

About this guide 5 About this guide Contents summary • Instructions on downloading and installing the approved driver and utilities • Instructions

Página 46 - Customer Self Repair

Support and other resources 50

Página 47

Support and other resources 51

Página 48 - Reparo feito pelo cliente

Regulatory compliance notices 52 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Página 49

Regulatory compliance notices 53 Disposal of waste equipment by users in private households in the European Union This symbol on the product or o

Página 50

Acronyms and abbreviations 54 Acronyms and abbreviations CIM common information model COS console operating system DA direct attached DVFS dynami

Página 51

Acronyms and abbreviations 55 VM Virtual Machine VMDK virtual machine disk format VMFS virtual machine file system VSL virtual storage layer VUM

Página 52 - • EMC Directive 2004/108/EC

Documentation feedback 56 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Página 53 - Korean class A notice

Index 57 A About this guide 5 authorized reseller 44 B before you begin 10 C command-line installation 12 command-line utilities 22 config

Página 54 - Acronyms and abbreviations

Index 58 P PCIe power override, enabling 23 PCIe power, enabling 19 performance and tuning 28 performance and tuning, introduction 28 perfor

Página 55

Introduction 6 Introduction Overview Designed around ioMemory, a revolutionary storage architecture, HP IO Accelerator is an advanced NAND flash sto

Página 56 - Documentation feedback

Introduction 7 Performance attributes IO Accelerator capacity Models AJ878B and BK836A 320GB 640GB NAND type MLC (Multi Level Cell) MLC (Multi Le

Página 57 - Index 57

Introduction 8 CAUTION: Version 3.1.1 of the driver software is not backward-compatible. When you install version 3.1.1, you cannot revert to any

Página 58 - Index 58

Introduction 9 BladeSystem c-Class IO Accelerators have two distinct designs for the respective server product lines. The G1 through G7 IO Accelerat

Comentários a estes Manuais

Sem comentários