HP ProLiant Generation ML310 Especificações Rápidas Página 37

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 36
System Unit
Tower Dimensions
(H x W x D)
(with feet/bezel)
14.5.x 6.89 x 18.71 in (36.82 x17.5 x 47.52 cm)
Tower Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
41.8 lb (18.96 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
25.29 lb (11.47 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
486 W
BTU Rating
Maximum
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
Power Supply Output
(per power supply)
Rated Steady-State
Power
350 W (at 100 VAC),
350 W (at 200 VAC)
Maximum Peak Power
350 W (at 100 VAC),
350 W (at 200 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).
QuickSpecs
HP ProLiant ML310e Generation 8 (Gen8)
Technical Specifications
DA - 14339 Worldwide QuickSpecs — Version 8 — 12/7/2012
Page 37
Vista de página 36
1 2 ... 32 33 34 35 36 37 38 39 40

Comentários a estes Manuais

Sem comentários