4
Figure 2: VMA SAN Gateway back view (P/N AM465A)
The FC HBA ports in the VMA SAN Gateway act as storage target ports which are connected to a FC
SAN Switch to provide host initiator port connectivity. The VMA SAN Gateway is only supported
with SAN Fabric attach; FC direct attach from a server FC port to a FC port on the gateway is not
supported. It is recommended that no more than two dual port 8Gb FC adapters (four target ports)
be deployed in the VMA SAN Gateway for each VMA-series Memory Array connected to avoid over
subscribing gateway and array resources. Four 8Gb FC ports (two dual port HBAs) are sufficient to
attain full I/O bandwidth of a single connected VMA-series array.
VMA-series Memory Arrays are connected to the VMA SAN Gateway using the VMA PCIe Pass-Thru
Card and directly connecting from the PCIe Pass Thru Card port to the Primary PCIe port of the VMA-
series Memory Array using the VMA 3-meter PCIe cable that ships with the VMA array.
Important: The VMA PCIe Pass-Thru cards must only be inserted into I/O slots 1 or 4 of the
VMA SAN Gateway (see above). The two FC 8Gb dual port adapters, which come with the
VMA SAN Gateway, are pre-inserted into I/O slots 2 and 3 of the gateway. If two VMA-
series Memory Arrays will be connected to the gateway, it is advised to order two additional
dual port 8Gb FC adapters, P/N AJ764A, for insertion into I/O slots 5 and 6. The VMA
SAN Gateway supports a maximum of two VMA-series Arrays and four dual port 8Gb FC
adapters (P/N AJ764A).
Note that the VMA PCIe cables and VMA Pass-Thru adapter card are not hot-pluggable. Connection
from the VMA SAN Gateway to the primary port of the VMA-series Array will require you to power
down the VMA SAN Gateway and the VMA Array. In order to have the PCIe busses of the VMA
array correctly connect electronically, you need to first power up the VMA array, wait until the PCIe
bus indicators light (about a minute) and then power up the VMA SAN Gateway. If the VMA SAN
Gateway is powered up before the VMA Array, the VMA array may not identify and be discovered
by the VMA SAN Gateway.
Only SAN attach is supported, meaning that connections from host servers to the SAN Gateway must
connect through a Fibre Channel SAN switch; direct FC attach from host server to SAN Gateway is
not supported.
One VMA PCIe Pass-Thru card must be ordered with each VMA-series Memory Array. Note that the
VMA PCIe cable is connected to the Primary PCIe port of the VMA-series Memory Array which is the
left-most port when viewing the back of the array.