3. Make a backup copy of /etc/vmware/esx.conf.
cp /etc/vmware/esx.conf /etc/vmware/esx.conf.orig
4. Identify the QLogic HBA module that is currently loaded.
vmkload_mod -l | grep qla2300
Depending on the model of the HBA, the module can be one of the following:
qla2300_707 (ESX 3.0.x)
qla2300_707_vmw (ESX 3.5)
5. The target port queue depth can now be modified via the service console command line using
VMware supplied binaries.
The example shows the qla2300_707 module. Use the appropriate module based on the
outcome of Step 4.
esxcfg-module -s ql2xmaxqdepth=42 qla2300_707
esxcfg-boot b
The server must now be rebooted for the changes to take effect.
6. Reboot the ESX host.
Upon boot up, the ESX host will now be throttled to a maximum of 42 outstanding commands
(as per the example in Step 5) to the target (HP 3PAR StoreServ Storage port).
NOTE: For additional information on changing the queue depth for HBAs, refer to the
VMware Fibre Channel SAN Configuration Guide.
ESX/ESXi 4.1, ESXi 5.x Additional Feature Considerations
ESX/ESXi 4.1 and ESXi 5.x introduce new features related to storage I/O control and integration
with storage arrays. HP recommends the usage of features SIOC and vStorage APIs for Array
Integration (VAAI) with ESX/ESXi 4.1, ESXi 5.x - HP 3PAR StoreServ Storage configurations.
NOTE: This section about VAAI and new additional features applies to all connectivity types:
FC, FCoE and iSCSI.
Storage I/O Control
The SIOC feature allows for a new level of monitoring and control of I/O from individual virtual
machines to an HP 3PAR StoreServ Storage array at the datastore level and across ESX/ESXi hosts
in a VMware cluster.
Further information regarding the SIOC feature and considerations for its deployment may be
found in the VMware technical white paper, Storage I/O Control Technical Overview and
Considerations for Deployment:
http://www.vmware.com/files/pdf/techpaper/VMW-vSphere41-SIOC.pdf
vStorage APIs for Array Integration (VAAI)
In partnership with VMware, HP has developed an ESX/ESXi 4.1 plugin that enables a new set
of SCSI commands to be used by ESX/ESXi 4.1 in conjunction with HP 3PAR StoreServ Storage.
VMware refers to this newly incorporated set of SCSI commands as the "primitives".
ESX/ESXi 4.1, ESXi 5.x Additional Feature Considerations 51