Basic Administrative Procedures and Setup Completion
36 NAS 4000s and 9000s Administration Guide
Setting up E-mail Alerts
E-mail messages are limited to the alerts generated from the WebUI status bar or the WebUI
status page, as well as some event log messages. Some alerts, such as the restart of the server,
only occur if the WebUI was utilized to initiate the request. For example, a restart initiated
using the WebUI will general an e-mail message indicating a restart has occurred. Initiating a
restart using the Windows Storage Server 2003 schedule or Desktop will not. Messaging in the
status bar and page is limited to the following areas:
■ WebUI Alerts
— NTBackup backup started
— NTBackup restore started
— Defrag started
— UPS power failure
— Restart pending
— Shutdown pending
— DFS not configured
— Date and time not configured
— No certificate
— Quota management alerts
■ Event Log Messages
— NTBackup Information
— UPS power failed
— UPS power restored
— UPS invalid config
— UPS system shutdown
— Quota management alerts
To activate this option:
1. From the WebUI, select Maintenance, Alert E-mail. The Set Alert E-Mail dialog box is
displayed.
2. Select Enable Alert E-mail.