Returning Firmware to Previous Versions
G06.24 Software Installation and Upgrade Guide—528593-005
15-6
Returning Bootcode Firmware to the Previous
Version (Using OSM)
15. Check that all SPs have completed successfully.
Returning Bootcode Firmware to the Previous
Version (Using OSM)
1. Log on to the OSM Service Connection.
2. Select Display> Multi-Resource Actions. The Multi-Resource Actions dialog box
appears with unselected fields.
3. From the Resource Type list, select SP.
4. From the Action list, select Processor Boot Millicode Firmware Update.
5. From the Filter by list, select Logical: Fabric Side-Y.
6. Click Add All to move the selected resources to update the lower list.
7. Click Perform Action.
8. Click OK when the Confirm Processor Boot Millicode Firmware Update dialog box
appears.
The Processor Parameter Input dialog box appears.
9. Enter the previous file location. Use the $volume.subvolume.filename
($SYSTEM.SYSnn) subvolume created during the most recent DSM/SCM
Build/Apply. For example:
$system.sys02.cpucode9
As the firmware update is performed, information about it appears in the Progress
List.
10. To verify that firmware resets are in progress, select Action Summary. The Action
Status Summary window appears with information about recent actions, including
their status and their overall progress.
11. Update the X-fabric for the processor boot code. From the Filter by list, select the
appropriate filter, Logical:Fabric Side-X.
VST956.vsd