g. Click OK. The changes do not take effect until the ESX host is rebooted.
For more information on rebooting an ESX host, see the following VMware KB article: http://
kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&
externalId=1003501.
2. Increase the number of CPU shares assigned to the ESX 3.X or ESX 4.X Service console:
a. Log in to vCenter from the Virtual Infrastructure Client with a user that has administrative
rights.
b. Select the VM Host from the left-hand side tree browser
c. Select Configuration.
d. From the Software panel, select System Resource Allocation.
e. Select Advanced.
f. From the System Resource Pools, select console.
g. Select Edit Settings.
h. Adjust the Shares: to High.
i. If the Reservation value is less than 0.5 of Limit: value, adjust the Reservation limit to 0.7
of the Limit: value. In the example below, Limit is: 3065 MHz and 0.7 of this value is
2145.