System Information and Statistics Commands
CLI Command Reference
September 2014 Page 162
HP Moonshot Switch Module CLI Command Reference
show fiber-ports optical-transceiver
This command displays the diagnostics information of the SFP like Temp, Voltage, Current, Input Power, Output
Power, Tx Fault, and LOS. The values are derived from the SFP's A2 (Diagnostics) table using the I
2
C interface.
Example: The following information shows an example of the command output:
(Routing) #show fiber-ports optical-transceiver all
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
-------- ---- ------- ------- ------- ------- ----- ---
1/1/1 39.3 3.256 5.0 -2.234 -2.465 No No
1/1/2 33.9 3.260 5.3 -2.374 -40.000 No Yes
1/1/3 32.2 3.256 5.6 -2.300 -2.897 No No
show fiber-ports optical-transceiver-info
This command displays the SFP vendor related information like Vendor Name, Serial Number of the SFP, Part
Number of the SFP. The values are derived from the SFP's A0 table using the I
2
C interface.
Format
show fiber-ports optical-transceiver {all | unit/slot/port}
Mode Privileged EXEC
Field Description
Temp Internally measured transceiver temperature.
Voltage Internally measured supply voltage.
Current Measured TX bias current.
Output Power Measured optical output power relative to 1mW.
Input Power Measured optical power received relative to 1mW.
TX Fault Transmitter fault.
LOS Loss of signal.
Format
show fiber-ports optical-transceiver-info {all | slot/port}
Mode Privileged EXEC
Field Description
Vendor Name The vendor name is a 16 character field that contains ASCII characters, left-aligned
and padded on the right with ASCII spaces (20h). The vendor name shall be the full
name of the corporation, a commonly accepted abbreviation of the name of the
corporation, the SCSI company code for the corporation, or the stock exchange code
for the corporation.