EMU Generated Condition Reports
184 Enterprise Virtual Array 3000 User Guide
1.3.en.02 CRITICAL ConditionHigh Current
This condition report indicates that an element current has reached the high
current CRITICAL threshold. This condition report remains active until the
problem is corrected.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
Backplane Conditions
Note: Backplane NVRAM errors usually occur during manufacture. At this time they
are identified and corrected. They rarely occur during normal operation.
The format of a backplane condition report is 8.2.01.ec, where:
8.2. is the backplane element type number
01. is the two-character backplane element number
ec is the error code
The only corrective action available for this error is to replace the drive enclosure.
8.2.01.10 NONCRITICAL ConditionBackplane NVRAM Read
An invalid NVRAM read occurred and an automatic recovery process has begun.
This condition report is active for 15 seconds.
If the automatic recovery process does not correct the problem, record all six
characters of the condition report, then contact your HP authorized service
representative.
8.2.01.11 NONCRITICAL ConditionBackplane NVRAM Write Failure
The system is unable to write data to the NVRAM. This problem prevents
communication between elements in the enclosure. This condition report is active
for 15 seconds.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.