HSV Controller Fault Management
190 Enterprise Virtual Array 3000 User Guide
Using Command View EVA
Command View EVA provides detailed information about each event affecting
system operation in either a Termination Event display or an Event display. These
displays are similar, but not identical.
GUI Termination Event Display
A problem that generates the Termination Event display prevents the system from
performing a specific function or process. You can use the information in this
display to diagnose and correct the problem.
Note: The major differences between the Termination Event display and the Event
Display are:
■ The Termination Event display includes a Code Flag field; it does not include the EIP
Type field.
■ The Event display includes an EIP type field; it does not include a Code Flag field.
■ The Event display includes a Corrective Action Code field.
The Termination Event display has the following format:
■ Date—The date the event occurred.
■ Time—The time the event occurred.
■ SWCID—Software Identification Code. A hexadecimal number in the range
0–FF that identifies the controller software component reporting the event.
■ Evt No—Event Number. A hexadecimal number in the range 0–FF that is the
software component identification number.
■ Code Flag—An internal code that includes a combination of other flags.
■ Description—The condition that generated the event. This field may contain
information about an individual field’s content and validity.
Date Time SWCID Evt No Code Flag Description