2. Define a target (for example, the primary system SystemA) on the backup system. On the
backup system (SystemB), enter:
• For RCFC:
# creatercopytarget <target_name> FC <node_WWN> <N:S:P>:<WWN> <N:S:P>:<WWN>
◦ <target_name> - Name of the Remote Copy target system (SystemA).
◦ FC - Specifies a Fibre Channel link.
◦ <node_WWN> - WWN of the target node (node 2FF70002AC000060 on SystemA).
◦ <N:S:P>:<WWN> - Fibre Channel adapter port on the backup system (SystemB),
expressed as node:slot:port, and the WWN of the peer port on the target system
(SystemA) (0:1:1:20110002AC000060 and 1:3:2:21320002AC000060).
• For RCIP:
# creatercopytarget <target_name> IP <N:S:P>:<IP_addr> <N:S:P>:<IP_addr>
◦ <target_name> - Name of the Remote Copy target system (SystemA).
◦ IP - Specifies an IP link.
◦ <N:S:P>:<IP_addr> - Node on the backup system (SystemB) that contains the IP
connections to the target system, expressed as node:slot:port, and the IP address for
the target system (SystemA) (2:4:1:10.100.33.96 and 3:4:1:10.101.33.96).
3. Define a second target system (for example, the asynchronous periodic backup system SystemC)
for the backup system. On the backup system (SystemB), enter:
# creatercopytarget <target_name> IP <N:S:P>:<IP_addr> <N:S:P>:<IP_addr>
• <target_name> - Name of the Remote Copy target system (SystemC).
• IP - Specifies an IP link.
• <N:S:P>:<IP_addr> - Node on the backup system (SystemB) that contains the IP
connections to the target system, expressed as node:slot:port, and the IP address for the
target system (SystemC) (2:4:1:10.100.33.63 and 3:4:1:10.101.33.63).
4. Start Remote Copy on the other backup system (for example, SystemC).
# startrcopy
5. Define a target system (for example, the primary system SystemA) for the second backup
system. On that system (SystemC), enter:
# creatercopytarget <target_name> IP <N:S:P>:<IP_addr> <N:S:P>:<IP_addr>
• <target_name> - Name of the Remote Copy target system (SystemA).
• IP - Specifies an IP link.
• <N:S:P>:<IP_addr> - Node on the backup system (SystemC) that contains the IP
connections to the target system, expressed as node:slot:port, and the IP address for the
target system (SystemA) (0:2:1:10.100.33.96 and 1:2:1:10.101.33.96).
60 Setting Up Synchronous Long Distance Remote Copy
Comentários a estes Manuais